• 제목/요약/키워드: Fire facility

검색결과 447건 처리시간 0.023초

그렌펠 타워 화재를 고려한 주거시설 화재안전에 관한 연구 (A Study on the Fire Safety of Residential Facility Considering Grenpel Tower Fire)

  • 이규민;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.69-70
    • /
    • 2017
  • Recently, The Building has became high rising and large scaling according to development of economy in domestic and other country, also the building has increased a variety of functions of insulation for warmth. and it has a symbol of economic growth, but it has risk factor for disasters such as fire. this hazards include not only general building but also residential building. Recently, Grenfell Fire that occurred in England has increased in combustion to the 24th floor of the 1st floor for 1 hour. it resulted in 80 deaths and 79 missing persons. In this study we suggest basic data of residential building for fire safety design related to domestic environment to analyze the problem of Grenfell Tower.

  • PDF

폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구 (A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities)

  • 이재영;전용한
    • 대한안전경영과학회지
    • /
    • 제23권1호
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

u-방재시스템 기반의 시설물 실시간 화재 모니터링 (u-Disaster Prevention System based Real-Time Fire Monitoring in a Building Facility)

  • 문성우;성현진
    • 한국건설관리학회논문집
    • /
    • 제12권1호
    • /
    • pp.107-114
    • /
    • 2011
  • 산업과 경제발전에 따라서 대중이 이용하는 공공 시설물은 대형화 복합화 되어가고 있으며, 재난시 시설물 사용자의 안전을 지키기 위한 방재 시스템의 역할이 더욱 중요해 지고 있다. 방재 시스템은 시설물관리에 있어서 재난극복을 위한 중요한 수단으로써 화재발생시 시설물 사용자를 안전하고, 신속하게 대피시킬 수 있는 기능을 가져야 한다. 본 논문에서는 화재 발생시 온도와 연기를 측정하여 현장상황에 대한 정보를 제공하는 Ubiquitous Sensor Network (USN) 기술 기반의 u-방재시스템을 제공한다. u-방재시스템은 화재발생시 유비쿼터스 환경에서 온도와 연기를 측정하여 현장상황에 대한 정보를 제공하는 등 독립적인 데이터 송수신 기능을 가지며, 시공간을 극복하여 현장상황을 실시간으로 모니터링 할 수 있다. 시설물 사용자는 방재시스템의 LED 전광판이 안내하는 상황별 최적의 대피경로를 따라서 화재로 부터 탈출할 수 있게 된다. 현장 적용성을 테스트하기 위해서 화재와 온도센서, 그리고 LED 전광판 등으로 구성되는 프로토타입을 개발했다. 빌딩 시설물을 대상으로 화재시 u-방재시스템의 기능을 검증했으며, 테스트 결과 USN 기반의 u-방재시스템은 화재발생 등 극한상황에서 화재대피에 필요한 데이터를 중단없이 송수신하여 시설물 사용자가 효과적으로 대피할 수 있도록 지원하는 것으로 나타났다.

위험물시설의 설계·시공·감리업 등록제 도입에 대한 타당성 검토에 관한 연구 (A Study on Assesment of Aalidity of Introducing of Design·Construction·Supervision Register Criteria Measures for Hazardous Materials Facilities)

  • 차정민;이용재;김인범;현성호
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.27-37
    • /
    • 2015
  • 본 연구에서는 현재의 미흡한 위험물시설설치에 대한 실태를 분석하고 소방시설설치를 위한 설계 공사 감리업에 대한 등록제 도입에 대한 타당성을 조사하여 합리적 기준안을 제안하고자 하며, 위험물시설에 대한 설계 시공 및 감리업 등록제 도입방안 연구를 통해 국가적으로 위험물 시설에 대한 전문적이고 높은 수준의 안전성 확보방안을 제안하였다. 이를 위하여 위험물시설의 설치와 관련하여 설계업과 감리업에 대한 등록기준을 제도화할 필요성이 있는 것으로 파악되었으며 공사업의 경우는 보다 점진적인 제도마련이 필요할 것으로 파악되었다. 또한 이를 뒷받침하기 위한 기술력의 육성과 확보를 위해 국가자격의 신설을 고려할 필요성이 있을 것으로 판단된다.

요양병원 소방안전관리의 효율화 방안에 관한 연구 (A Study on the Effective Method of Fire Safety Management of Geriatric Hospitals)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.83-88
    • /
    • 2016
  • Currently many geriatric hospitals have been built in Korea because increasing aging rapidly. However the increasing geriatric hospitals make the increasing safety accidents. Therefore this study is conducted by survey and face-to-face talk with the fire safety managers for analyzing safety problem of geriatric hospitals which number is twelve among 15 geriatric hospitals in the north of Chung-buk area. The result of this study is that geriatric hospitals are very old. Fire safety managers holding the fire safety license are a level 2 issued by the Korea Fire Safety Association(KFSA). And the fire safety inspection ability of them is normal (58%). Furthermore a fire safety budget ratio is 83% (A little) in the company yearly budget. And ratio having the fire inspection equipment in the building is 42% (A little) and 33% (Nothing). Satisfaction ratio of their duty is 66% and they also get stress from heavy duty and heavy responsibility. In conclusion, CEO needs to invest and interest the improvement of job performance, satisfaction ratio and fire safety facility. Also government needs the improvement of system to support and supervise the fire safety of geriatric hospitals consistently.

소방대의 현장접근성 강화를 위한 설비의 개선방안 (The Way for improvement of facility to strengthen accessibility of the site for fire department)

  • 오택흠;성재만;박찬석
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

화재연구를 위한 대형 콘 칼로리미터의 설계 (Design of Large Cone Calorimeter for the Fire Study)

  • 이의주
    • 한국화재소방학회논문지
    • /
    • 제20권4호
    • /
    • pp.65-71
    • /
    • 2006
  • 최근에 화재연구가 활발해짐에 따라 화재특성을 평가하기 위해 중요한 물리량인 발열량 등을 측정하여 모델의 검증과 화재현상의 이해를 도모하고 있다. 이전의 화재연구에서는 실험공간이나 재정적 여건 때문에 축소모형 실험을 주로 수행하였지만, 다양한 화재의 특성을 축소모형에서 모두 도출할 수 없으므로 실제 규모의 화재에서 특성을 조사하는 것이 필요하다. 그러므로 보통 5MW 이상의 열량을 측정할 수 있는 대형 콘 칼로리미터를 20년 전부터 외국에서는 개발하였으며, 새로운 관련기술과 화재에 관한 지식을 바탕으로 개선되고 발전되어 왔다. 본 연구에서는 대형 콘 칼로리미터를 설계할 때 고려하여야 할 방법들을 각 요소별로 설명하고, 이를 통해 향후 개선을 위해 요구되는 지식이나 기술들을 제안하였다.

액체로켓 추진기관 시험설비 기반시설 고찰 (Infrastructure of Propulsion Test Facility of Liquid Rocket)

  • 조남경;김성혁;한영민
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.87-94
    • /
    • 2019
  • 액체로켓 추진기관 시험설비는 시험대상체가 상위 시스템에 장착되었을 때의 인터페이스 조건을 모사하여야 하며, 시험 시 파손이 발생할 수 있는 개발품의 특성상, 안전하게 시험이 이루어질 수 있게 구축되어야 한다. 이를 위해 추진기관 시험설비 기반시설은 안정적인 연소가 이루어지고 사고 시에도 안전이 보장되도록 구축되어야 한다. 본 논문에서는 액체로켓 엔진 추진기관 시험설비 기반시설의 구축 및 운영 시 고려해야 할 사항에 대해, 토목/건축, 시험 스탠드, 설비의 배치, 타 설비와의 운영 조합 및 공동구, 소화설비, 전력설비 측면에서 고찰하였다.

혼산 저장설비 사고의 근본원인 분석을 통한 안전성 향상방안 (A Study on the Safety Improvement of Mixed Acid Storage Facility through the Accident Investigation Applicated by RCA)

  • 권남호;김동준
    • 한국위험물학회지
    • /
    • 제6권2호
    • /
    • pp.47-54
    • /
    • 2018
  • Mixed acid is very reactive and highly corrosive. it has been causing many accidents in a electronic industry, a steel industry, and a chemical industry. Therefore, it is required that the high safety level for the acid storage facilities. In this study, we investigated the accident causes for resent leak accidents with Root Cause Analysis (RCA). The root causes analysed by RCA were categorized as nine divisions by the their characteristics. Furthermore, each nine divisions causes was applied to the PDCA model which are using at OHSAS 18001. It is suggested that the nine division with the root causes can be the essential items for the development of the safety management manual. It is helpful to the safety improvement of the acid storage facility.

일개 노인요양병원의 피난안전성능 평가에 관한 연구 (A Study on the Evaluation of Evacuation Safety Function of an Elderly Care Hospital)

  • 김종범;김자옥;백은선
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.9-19
    • /
    • 2010
  • 최근 우리나라는 노인요양병원이 꾸준히 증가하고 있으며 화재등과 같은 비상 상황에서 노인의 행동 특성과 신체 상태를 고려한 종합적인 피난계획의 수립이 요구된다. 또한 시설 이용자의 대부분이 중증의 치매 및 뇌졸중을 앓고 있는 환자이기 때문에 자력으로 피난이 곤란하고 환자의 보행상태(침대, 휠체어, 각종 보조기구) 등에 따라 피난시간이 상이하여 이용자 전원을 피난시키는 것이 어렵기 때문이다. 본 논문은 성능위주의 설계 시 참고가 될 자료를 제시하기 위해 의료시설인 노인요양병원을 모델로 여러 수집된 자료들로 Simulex를 이용하여 피난시간을 측정하였다. 이 연구의 과정에서 몇 가지 문제시 되는 사항을 발견할 수 있었다.