• Title/Summary/Keyword: Fire escape

Search Result 233, Processing Time 0.024 seconds

A Study on the Actual Condition of the Obstacles on the Apartment Escape Stairs and the Perception of Residents (아파트 피난계단에 적치된 장애물의 실태와 입주민의 피난계단 관리에 대한 인식에 관한 연구)

  • Lee, Wonjoo;Lee, Chang-Seop;Lee, Kiyoung
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.116-123
    • /
    • 2017
  • The purpose of this paper is to improve the evacuation stability of residents in apartment fire. For this purpose, the actual condition survey about the obstacles was conducted on 3,056 escape stairs in the 183 apartments. In addition, the questionnaire investigation was carried out a survey targeting the residents of apartments about their experience of fire safety education, perception on safety management of escape stairs, and perception on fire safety. As a result of investigation, we confirmed that the obstacles were formed in the 1,916 escape stairs among the 3,056 escape stairs of the 183 apartments (percent of barricades in escape stairs: 62.70%). Furthermore, it showed that fire safety education experience was found to be 83.10% of subject. The perception on safety management of the subjects in the escape step and the perception on fire safety were $3.84{\pm}0.75%$, and $3.49{\pm}0.61$, respectively. In the results, most of the subjects had a fire safety education and knew how to safety management the escape stairs but, the practice of the safety management action was low. Based on the results in the paper, the policy proposal is that the fire safety education is emphasized to change from the perception to action.

Safety Assessment of the Evacuation at School Building by Escape Training and Simulation (학교건물에서 피난훈련과 시뮬레이션을 통한 피난안전성 평가)

  • Jeong, Mu-Heon;Lee, Beong-Gon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • In this study, the evacuation training were performed in a high school building in Cheong-Ju and compared with the simulation program (Simulex). Also numerical analysis of room fire in school building was conducted by fire model (FDS, CFAST) and evaluated the available safe egress time for the safety assessment. As a result, the 8% of total egress persons were failed to escape at evacuation training and 40% of total egress persons were failed to escape at Simutex simulation. Simutex program was not reflected the real escape conditions, such as evacuation route, refuge place, etc.

The development of the escape light control system (유도등 제어시스템의 개발)

  • Kim, Dong-Ook;Mun, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.52-58
    • /
    • 2009
  • When a fire breaks out, it is frequent that large sized miserable death is happened by seriousness of poisonous gas and peculiarity of space because the building construction is recently more complex and diverse. So early countermeasure in preparation for evacuation escape linked directly with a loss of lives is pressing. Because escape light that mark fixing one-way of existing way is not efficiently extricated refugees from dangers when a fire breaks out, construction of system that can extricate refugees from dangers and suppress early a fire by grasping correctly fire point is required urgently. When a fire breaks out, all escape lights connected with fire sensor and reception group which have ill aiming in these point will lead people to safe emergency entrance of opposite direction of place that a fire is broken out after being calculated the direction and speed of flame and smoke. There is the purpose of my research in development of artificial intelligent directional escape light that can mark direction to most suitable pull-out and assist in early extinguishing a fire.

A Study on the Improvement Direction of the Building Escape Regulation Considering Inconvenient Movers (이동약자를 고려한 건축물 피난규정 개선 방안에 관한 연구)

  • Hwang, Eun-Kyoung
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • Owing to increase of the large-scaled, high-raised and complexed building construction, the escape design of the building became very important issue to insure the safety of occupant. Specially, it is demanded to have building escape regulation considering for inconvenient movers such as disables elders pregnant women. However, building regulations for inconvenient movers are divided into "Regulation of Escape and Fire-prevention of Building" and "Act on the Promotion and Guarantee of Access for the Disabled, the Aged and Pregnant Women to Facilities and Information". But, for the escape security of inconvenient movers, the connection of each regulation are necessary. So this study suggested the improvement direction of the building escape regulation considering inconvenient movers through the compared analysis on the "Regulation of Escape and Fire-prevention of Building" and "Act on the Promotion and Guarantee of Access for the Disabled, the Aged and Pregnant Women to Facilities and Information".

A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building - (우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 -)

  • Lee, Se-Myong;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-41
    • /
    • 2011
  • Regulation of Escape and fire-prevention of Building of South Korea were enacted as a part of building codes in 1962. Since it was enacted, the law has gone through many changes. In this study, evaluated the fire safety of the law about the case of a hotel that the fire risk are expected to be higher whenever it was changed. As a result, the current law has gotten better in tire safety since it was enacted. However, especially it could be confirmed that the evacuation safety is insufficient in the lower level of hotel building. In the case of accommodation, because the occupants become aware of fire lately, they have not enough time to escape. Therefore, this study suggests that it is needed to come up with an effective counterplan about the interior finish materials, fire door and fire compartments that the smoke layer descending time is longer.

A Study of Proper Space between the Escape Tunnels in the Long Railway Tunnel (철도장대터널의 대피통로 최적간격에 관한 연구)

  • Kim Dong Gi;Park Byung Eun;Rha Sang Ju;Park Jong Kwaun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.880-885
    • /
    • 2004
  • When a fire takes place, the escape tunnel which could prevent passengers and the crew from disasters would be most important facility among railway tunnel facilities for prevention of disaster. A shorter space between the escape tunnels is much better for safety because of short escape time. The establishment of short space escape tunnels(driftways) in the single track parallel tunnel is much easier. The establishment of long space escape tunnels(inclined shafts, vertical shafts) in the double track is much more advantageous economically. We, therefore, compared the movement time of smog originated from fire with the escape time of the crew and passengers for setting up the best space between the escape tunnels in the double track tunnel. We could calculate the best space between the escape tunnels in the double track tunnel properly by computer simulation.

  • PDF

A Study on the Fire Safety of High-rise Office Buildings in Respect of Architectural Design (고층 사무소건축의 화재안전에 관한 건축계획적 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.8 no.2
    • /
    • pp.3-15
    • /
    • 1994
  • The purpose of this paper is to present refernce data to be considered in designing for the fire safety of high-rise office buildings. This paper deals with the characteristics of high-rise office buildings in the fire safety aspects, the basic principles for the fire safety of high-rise office building design, and this study is focused particularly on the location of the escape route of core plan for fire safety in high-rise office buildings.

  • PDF

A Study on the Development of Intelligent Guiding Exit Sign System (지능형 피난유도 시스템 개발에 관한 연구)

  • Kim, Yoo-Shik;Sug, Dong-Sub
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.131-134
    • /
    • 2006
  • As modern buildings grow to become diversified, toxic gases and smoke coupled with characteristics of space during a fire increase the risk of large-scaled disaster. It is now urgent to take measures for evacuation and escape directly linked to personal damage. Existing fixed one-way emergency exit light is not enough for efficient evacuation and rescue. Therefore, to ensure quicker escape and evacuation during a fire, two-way radio data system should be devised, which linked with fire detector, helps people in danger to escape quickly and is able to control by a central control system, and the system was found to enhance the efficiency of escape and contribute to safer escape.

Design and Implementation of a service system for providing an optimal fire escape route based on context-awareness (상황인지 기반의 화재 대피 최적경로 제공 서비스 시스템 설계 및 구현)

  • Bae, Nam Jin;Kim, Tae Hyung;Jeong, Ho Seok;Cho, Yong Yun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.63-71
    • /
    • 2012
  • Recently, because most of buildings in the city become bigger and higher, so various convenient facilities and high-tech management skills are required to prevent potential disasters. Especially, because fires in huge buildings can cause serious damage, technologies and methods that help people quickly and safely to escape from the building is very important to extinguish the fire in initial state and to minimize the damage. This paper suggests a context-aware service system that can provide optimal escape routes to tenants with their smart-phones. The proposed system collects contexts with real time through USN(Ubiquitous Sensor Network) and provides an optimum escape route based on the collected contexts through service users' smart phones. In addition, The system provides not only safe routes from the fire but also valuable information for rescue operations with real time.

How Visual-Field Obstruction from Fire Smoke Influences a Resident's Necessary Time to Reach Fire Escape and Evacuation Route in a High-rise Apartment Housing (연기발생으로 인한 시야장애가 초고층 공동주택 거주자의 피난계단실 진입시간과 피난경로에 미치는 영향)

  • Seo, Sang-Mok;Choi, Jun-Ho;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • The purpose of this study is to know how visual-field obstruction from fire smoke influences a resident's necessary time to reach fire escape and evacuation movement in a high-rise apartment housing. Generally, fire smoke not only gives visual-field obstruction and breath troubles to residents but interrupts their evacuation behavior. If a fire smoke layer is formed in the core department when evacuee enters at the evacuation staircase until, residents will be made to undergo a range of vision obstacle. In order to set a situation like that, participants wore eye bandage which had been made especially before the experiment. Also as a comparative standard, through no.1442 Japanese construction ministry notices about the building evacuation safety verification method, this study calculated smoke layer's dissent time and evacuation time. Then to compare with the former, the participants without an eye bandage joined a experiment once again. This study has understood how fire smoke effects on one's evacuation delay by analyzing residents' evacuation time to reach the staircase and movement route, however, in this study a toxic gas is not considered because it might threaten participants not to breathe.