• Title/Summary/Keyword: Fire analysis

Search Result 3,409, Processing Time 0.028 seconds

Improvement of Fire Detection in Rack-type Warehouses using FDS (FDS를 이용한 랙크식 창고의 화재감지 개선에 관한 연구)

  • Choi, Ki-Ok;Park, Moon-Woo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.55-60
    • /
    • 2019
  • The occurrence of fire in rack-type warehouses may either lead to the warehouses getting entirely burned up or collapsing. This can be attrubuted to the high height of rack-type warehouses, in which combustibles are generally vertically stacked. These characteristics make it difficult to detect a fire early; because detectors are installed on the ceiling, these fires cannot be extinguished at an early stage. In this study, the flow of heat and smoke generated by a fire in a rack-type warehouse was analyzed using a fire dynamic simulator. Through this analysis, the optimal installation conditions of fire detectors for the early detection of fire in rack-type warehouses were confirmed. The analysis results confirmed that complex detection of heat and smoke is required for the early detection of fire in rack type warehouses. Furthermore, it was found that fixed temperature detectors are not suitable for these warehouses, resulting in the need to install heat-smoke hybrid detectors at every three rack levels.

A Study on the Current State and Improvement of Operation of Fire Investigation Teams (화재조사 실태 분석과 개선방안에 관한 연구)

  • Lee, Tae-Geun;Chae, Jong-Min
    • Journal of forensic and investigative science
    • /
    • v.1 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • The purposes of fire investigation are to identify and analyze the causes of fire and, using the results in promoting fire fighting policies, ultimately to prevent fires caused by similar causes and to protect people's life and properties from fire. However, although the patterns of fire are getting more diverse and complicated with the rapid development of industry, complicated with the rapid development of industry, fire fighting organizations are continuing traditional superficial fire investigation without operating a fire investigation department for the reason of insufficient manpower, equipment and budget, losing public confidence. Thus, the present study purposed to propose plans to improve the technicality of fire investigation and win public confidence in fire investigation. First, the technicality of fire investigation should be improved by operating a department and personnel exclusively for fire investigation. Second, fire investigation should be more scientific and precise using high tech fire investigation equipment. Lastly, responsible fire fighting administration should be realized through statistical analysis of the causes of fire and computerization. The results of this study are expected to contribute to the safety and security of our society.

  • PDF

A Study on the Proposal of Durability and Service Life of Fire Door in apartment house (공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구)

  • Kwon, Yeong-Jin;Kim, Yun-Seong;Jin, Seung-Hyeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

Safety Analysis of Hazmat Tank Foundation to Prevent Tank Fire (위험물탱크 화재방지를 위한 기초 안정성 분석연구)

  • Choi, Jeong-Soo;Lim, Jong-Jin;Choi, Young-Seok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.165-172
    • /
    • 2008
  • Leakage incidents due to the fault of hazmat tank foundations are likely to cause the tremendous fire disaster in the national industry cluster area. The proper design and construction of tank foundation should be required to prevent the tank fire. In the study, the types of typical tank foundations were classified and modeling the individual tank type for 3D FEM analysis was performed to suggest the guideline for the design and construction of tank foundations. Matters to be attended of the foundation design and construction are reviewed through the comparison assessment of the numerical analysis results of the foundation types.

  • PDF

Performance Analysis of an Inert Gas Generator for Fire Extinguishing

  • Kim, Su-Yong;Arkadiy F. Slitenko
    • 연구논문집
    • /
    • s.29
    • /
    • pp.5-15
    • /
    • 1999
  • Present study deals with performance analysis of an inert gas generator (IGG) which is to be used as an effective mean to suppress the fire. The IGG uses a turbo jet cycle gas turbine engine to generate inert gas for fire extinguishing. It is generally known that a lesser degree of oxygen content in the product of combustion will increase the effectiveness of fire suppressing. An inert gas generator system with water injection will bring advantages of suffocating and cooling effects which are considered as vital factors for fire extinguishing. As the inert gas is injected to the burning site, it lowers the oxygen content of the air surrounding the flame as well as reduces the temperature around the fire as the vapour in the inert gas evaporates during the time of spreading. Some important aspects of influencing parameters, such as, air excess coefficient. $\alpha$, compressor pressure ratio, $ pi_c$, air temperature before combustion chamber, $T_2$, gas temperature after combustion chamber, $T_3$, mass flow rate of water injection, $M_w$, etc., on the performance of IGG system are investigated. Calculations of total amount of water needed to reduce the turbine exit temperature to pre-set nozzle exit temperature employing a heat exchanger were made to compare the economics of the system. A heat exchanger with two step cooling by water and steam is considered to be better than water cooling only. Computer programs were developed to perform the cycle analysis of the IGG system and heat exchanger considered in the present study.

  • PDF

ANALYSIS OF STEADY FIRE-DRIVEN FLUID FLOW FOR RAILWAY TUNNEL BY DIFFERENT VELOCITY CONDITIONS AT THE END OF TUNNEL (종단부 유속조건 변화에 따른 철도터널 내 정상상태 화재유동해석)

  • Lee, D.C.;Lee, D.H.;Jung, W.S.;Park, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.208-213
    • /
    • 2010
  • In this study CFD(Computational Fluid Dynamics) analysis of the steady fire-driven fuid flow for the performance test of ventilation at railway tunnel between Heuksok and Nodeul Station from Seoul Metro 9 is performed. There were fans with exhaust and intake modes and each was installed at the middle and both ends of the tunnel. For this test, the pool fire source of methyl alcohol with 1.5MW and smoke generators were installed between the middle of tunnel and Heuksok Station. In this test, the smoke behavior from natural convection was observed for 10 minutes from the ignition of pool fire and then fans with intake-modes at both sides of Heuksok effect of fan-on with intake mode located in the opposite side of the tunnel nearby Heuksok Station on fire-driven fluid flow is studied on when the boundary conditions of fan-on at the tunnel between Heuksok and Nodeul Station are the same as test. FLUENT, a commercial CFD code, is used for this analysis.

  • PDF

A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine (드럼세탁기 화재안전성 확보를 위한 실험연구)

  • Hong, Sung-Ho;Lee, Sang-Hyun;Park, Sang-Tae;Yu, Hyun-Jong;Jeon, Woong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

Latest passenger vehicle fire trend and case study based on field investigation data (차량화재 사고경향 및 사례분석)

  • Shin, Junho;Won, Eugene;Hong, Ilmin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Based on the analysis of the actual passenger vehicle fire cases for recent four years (2010~2013), the passenger vehicle fire is increasing annually. Main root cause was analyzed as an electric problem as a 39%. Vehicle fire case by electric problem was mainly caused by use of Non-genuine part. Vehicle fire case by mechanical problem was mainly caused by various oil system maintenance. Vehicle fire case by smoking material was mainly caused by cigarette and disposal lighter. And external fire transition issue and towing mistake fire cases was also confirmed.

Analysis of Policies to Activate the Volunteer Fire Brigade in Japan (일본 의용소방대 활성화 정책의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.64-73
    • /
    • 2011
  • Japan is a representative state where the volunteer fire brigade consisting of private citizens is well developed although it has an advanced fire fighting system established by local governments. Japan realized the limitation of response by governmental fire fighting system when large-scale natural disasters such as earthquake or typhoon and has developed and promoted several policies to activate the volunteer fire brigade. This study analyzes the policies of the volunteer fire brigade in Japan in detail and suggests policies which can be introduced to activate the volunteer fire brigade in Korea.

Analysis on Visibility Range of Forest Fire Detection Facilities for Forest Fire Prevention (산불예방을 위한 감시시설 가시범위 분석에 관한 연구)

  • Lee, Si-Young;An, Sang-Hyun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.157-160
    • /
    • 2008
  • This study analyzed on the area of Samcheok, Kangwondo about forest fire alarming area and enlargement of the area. Then, visible area by unattended watching camera and watchtower for forest fire which were run by Samcheok was cross-checked with geographic information system, and it could be whether effective on watching the area where the forest fire risk was high enough and also it could be expanded to larger forest fire. The result of study, the visible area by watching facilities only holds for 13.4% of the whole forest fire alarming area, but the forest fire can be observed even though it is occurred in small valley because of smoke and all the forest fire have been occurred in daytime. Therefore, it can be determined that watching area will be extended around 50.3% while the observation radii of watching facilities raise by 4km. However, Samcheok has much greater area of mountain area in compared to any other cities or counties, watching facilities should be installed and run additionally for extinguishing the forest fire from the beginning.

  • PDF