Analysis on Visibility Range of Forest Fire Detection Facilities for Forest Fire Prevention

산불예방을 위한 감시시설 가시범위 분석에 관한 연구

  • 이시영 (강원대학교.방재기술전문대학원) ;
  • 안상현 (충북대학교 정보산업공학과)
  • Published : 2008.02.28

Abstract

This study analyzed on the area of Samcheok, Kangwondo about forest fire alarming area and enlargement of the area. Then, visible area by unattended watching camera and watchtower for forest fire which were run by Samcheok was cross-checked with geographic information system, and it could be whether effective on watching the area where the forest fire risk was high enough and also it could be expanded to larger forest fire. The result of study, the visible area by watching facilities only holds for 13.4% of the whole forest fire alarming area, but the forest fire can be observed even though it is occurred in small valley because of smoke and all the forest fire have been occurred in daytime. Therefore, it can be determined that watching area will be extended around 50.3% while the observation radii of watching facilities raise by 4km. However, Samcheok has much greater area of mountain area in compared to any other cities or counties, watching facilities should be installed and run additionally for extinguishing the forest fire from the beginning.

Keywords