• Title/Summary/Keyword: Field heat

Search Result 2,036, Processing Time 0.024 seconds

A Field Measurement Study on Heat Storage/Emission Characteristics of Tower Type Apartment Structures in Winter Season (겨울철 난방시 탑상형 아파트 구조체의 축·방열 특성에 대한 현장측정 연구)

  • Chang, Hyun-Jae;Cho, Keun-Je
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.190-195
    • /
    • 2012
  • In this study, as a complementary study of the former study on indoor thermal environment in a tower type apartment house at tropical nights, a field measurement was conducted in winter season. Mainly, characteristics of heat storage and heat emission in apartment structures, in this study, were investigated. As results, indoor air temperature was changed in the range of $22.5^{\circ}C{\pm}1.0^{\circ}C$, and followed not the change of outdoor air temperature but the changed pattern of floor surface temperature. Wall surface temperature was unresponsive to the change of floor surface temperature compared with the change of indoor air temperature because wall structure was composed of concrete which has large heat capacity, and was changed in the range of $22.3^{\circ}C{\pm}0.6^{\circ}C$. Heat was stored continuously into the structures of wall and ceiling through the measurement term. and this means that a large heat capacity of the apartment structure acts as a disadvantage in winter season, too. As a total review of the study with the former study, a large heat capacity of the apartment structure acts against indoor thermal comfort in winter season as well as in summer season.

UNSTEADY HARTMANN FLOW WITH HEAT TRANSFER IN THE PRESENCE OF UNIFORM SUCTION AND INJECTION

  • Attia Hazem A.
    • The Pure and Applied Mathematics
    • /
    • v.13 no.1 s.31
    • /
    • pp.1-10
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to a constant pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the magnetic field and the uniform suction and injection on both the velocity and temperature distributions is examined.

  • PDF

Flow and heat transfer analysis for the performance improvement of cross-flow fin-tube heat exchangers (에어컨 실외기용 휜-관 직교형 열교환기의 열, 유동 해석 및 휜 성능 개선을 위한 연구)

  • An C. S.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.183-189
    • /
    • 2004
  • The flow and the heat transfer about the cross-flow fin-tube heat exchanger in an out-door unit of a heat pump system has been numerically Investigated. Using the general purpose analysis code, FLUENT, the Navier-Stokes equations and the energy equation are solved for the three dimensional computation domain that encompasses multiple rows of the fin-tube. The temperature on the fin and tube surface is assumed constant but compensated later through the fin efficiency when predicting the heat-transfer rate. The contact resistance is also taken into consideration. The flow and temperature fields for a wide range of inlet velocity and fin-tube arrangements are examined and the results are presented in the paper. The details of the flow are very well captured and the heat transfer rate for a range of inlet velocity is in excellent agreement with the measured data. The flow solution provides the effective permeability and the inertial resistance factor of the heat exchanger if the exchanger were to be approximated by the porous medium. This information is essential in carrying out the global flow field calculation which, in turn, provides the inlet velocity lot the microscopic temperature-field calculation of the heat exchanger unit.

  • PDF

Study on Heating Performance of Hybrid Heat Pump System Using Geothermal Source and Solar Heat for Protected Horticulture (시설원예용 지열 및 태양열 이용 하이브리드 히트펌프 시스템의 난방성능에 관한 연구)

  • Jeon, Jong Gil;Lee, Dong Geon;Paek, Yee;Kim, Hyung Gweon
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.49-56
    • /
    • 2015
  • In this study a hybrid heating system based on geothermal source and solar heat was developed in order to save energy for greenhouse heating and its field performance was evaluated. Developed system are composed of following parts: water tank, heat exchanger, heat pump, fan coil unit and heat storage unit. The working performance test was carried out in a greenhouse cultivating oriental orchids being managed by $23^{\circ}C$. Field performance test results showed that average heating coefficient of performance ($COP_h$) was 3.4 for the period from mid-January to mid-March 2013. Heating coefficient of performance ($COP_h$) of developed hybrid heat pump system was more sensitive to water tank temperature than outside air temperature. This study showed that developed hybrid heat pump system has a potential to save the heating costs up to 91% compared to conventional agricultural oil heaters.

Application of the Modified Equivalent Specific Method to the Phase Change Heat Transfer (개량된 등가비열법을 이용한 상변화 열전달의 수치해석)

  • Mok Jinho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.814-819
    • /
    • 2005
  • The phase change heat transfer has been applied to the processes of machines as well as of manufacturing. The cycle in a heat exchanger includes the phase change phenomena of coolant for air conditioning, the solidification in casting process makes use of the characteristics of phase change of metal, and the welding also proceeds with melting and solidification. To predict the phase change processes, the experimental and numerical approaches are available. In the case of numerical analysis, the Enthalpy method is most widely applied to the phase change problem, comparing to the other numerical methods, i.e. the Equivalent Specific Heat method and the Temperature Recovery method. It's because that the Enthalpy method is accurate and straightforward. The Enthalpy method does not include any correction step while the correction of final temperature field is inevitable in the Equivalent Specific Heat method and the Temperature Recovery method. When the temperature field is to be used in the calculation, however, there must be converting process from enthalpy to temperature in the calculation scheme of Enthalpy method. In this study, an improved method for the Equivalent Specific Heat method is introduced whose method dose not include the correction steps and takes temperature as an independent variable so that the converting between enthalpy and temperature does not need any more. The improved method is applied to the solidification process of pure metal to see the differences of conventional and improved methods.

Closed-Loop Cooling System for High Field Mangets (고자기장용 자석을 위한 밀폐순환형 냉각장치)

  • Choi, Y.S.;Kim, D.L.;Lee, B.S.;Yang, H.S.;Painter, T.A.;Miller, J.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.

Conceptual Design of High-Tc Superconducting Current leads for Superconducting Nuclear Fusion Magnets with respect to various HTS tapes (HTS 선재에 따른 초전도 핵융합 마그넷용 고온초전도 전류도입선의 개념설계)

  • Jang, J.Y.;Chang, K.S.;Kim, Y.J.;Choi, S.J.;Jo, H.C.;Chu, S.Y.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.32-36
    • /
    • 2010
  • Superconducting current leads are indispensible for reducing power loss when subjecting current into superconducting magnets. HTS(High-Tc superconducting) current leads are divided into two types; one is bulk type and the other is tape type. In this paper, conceptual design on the HTS current leads which adopts tape type for nuclear fusion magnets is carried out using magnetic field analysis and thermal analysis. When large current flows through superconducting current leads, strong self magnetic field is generated and applied to the superconducting tapes. This phenomenon leads to the critical current decrease of the superconducting tape. Therefore, we analyzed magnetic field distribution of current leads and found the proper arrangement with respect to the various HTS tapes. In addition to the magnetic field analysis, heat leak through the current leads was also calculated to know which HTS tape is superior than others in thermal aspect. Magnetical field analysis and calculation of heat leak are performed to design 2 kA class HTS current leads.

Field Measurement of Hydration Heat and Field Aaaplication of Pipe Cooling System (수화열 계측 및 파이프쿨링 시공 사례)

  • 최계식;양주경;최영돈;최고일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.381-386
    • /
    • 1994
  • Recently, the design and construction of massive concrete structures are increased. But, the temperature rise within a large concrete mass make the construction of massive concrete structures be very difficult. Therefore, in Seohae Grand Bridge Project, the field measurement of hydration heat for the massive concrete footings(11$\times$22$\times$4m) was carried out. It was shown to be possible to construct the massive concrete footing successfully by application of pipe cooling system. And the measurement results showed that standard code for concrete practice was very conservative.

  • PDF

A Study on the Temperature Distribution and Deformation of Case in Shrinkage Fit Process(I) - Temperature Monitoring and Heat Transfer Analysis Model - (열박음 공정이 케이스의 온도분포 및 변형에 미치는 영향(I) - 온도 계측 및 열전달 해석 모델 정립 -)

  • 장경복;조상명;강성수
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.384-390
    • /
    • 2001
  • There have been many problems due to deformation in industry field. Especially, it is severe in parts with small size and thin thickness and in products that must have excellent airtightness and anti-noise. The countermeasures for this deformation in field have mainly been dependent on the rule of trial and error by operator's experience because of productivities. Systematic study about this product with deformation is also insufficient that deformation is complex problem with shape, size, material of product, joining method and conditions, etc.. It is efficient to apply CAE technique without influence on productivity to this problem. There is, however much difference between the result analyzed by CAE and appearances in working field because of the insufficiency of communication between simulator and worker and of sensing data for boundary condition in analysis. In this study, to solve this deformation problem, we intend to make a simulation model that is adapted from working conditions by tuning and feedback between sensing data and simulation results. This paper include temperature monitoring and make a heat transfer model using sensing data in product as previous step for deformation analysis. The heat transfer analysis of shrinkage fit process is considerably difficult due to contact heat transfer between case and core. To solve this contact problem, gap element is used in present study.

  • PDF

Determination of Weighting Factor in the Inverse Model for Estimating Surface Velocity from AVHRR/SST Data (AVHRR/SST로 부터 표층유속을 추정하기 위한 역행렬 모델에서 가중치의 설정)

  • Lee, Tae-Shin;Chung, Jong-Yul;Kang, Hyoun-Woo
    • 한국해양학회지
    • /
    • v.30 no.6
    • /
    • pp.543-549
    • /
    • 1995
  • The inverse method has been used to estimate a surface velocity field from sequential AVHRR/SST data. In the model, equation system was composed of heat equation and horizontal divergence minimization and the velocity field contained in the advective term of the heat equation, which was linearized in grid system, was estimated. A constraint was the minimization of horizontal divergence with weighting factor and introduced to compensate the null space(Menke, 1984) of the velocity solutions for the heat equation. The experiments were carried out to set up the range of weighting factor and the matrix equation was solved by SVD(Singular Value Decomposion). In the experiment, the scales of horizontal temperature gradient and divergence of synthetic velocity field were approximated to those of real field. The neglected diffusive effect and the horizontal variation of heat flux in the heat equation were regarded as random temperature errors. According to the result of experiments, the minimum of relative error was more desirable than the minimum of misfit as the criteria of setting up the weighting factor and the error of estimated velocity field became small when the weighting factor was order of $10^{-1}$

  • PDF