• Title/Summary/Keyword: Facility Monitoring

Search Result 578, Processing Time 0.027 seconds

A Study on the Visualization of Facility Data Using Manufacturing Data Collection Standard (제조설비 데이터 수집 표준을 이용한 설비 데이터 시각화에 대한 연구)

  • Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.3
    • /
    • pp.159-166
    • /
    • 2018
  • This paper introduces a manufacturing facility visualization system for the monitoring of smart factories. With the development of technology and the emergence of such terms as the Fourth Industrial Revolution and Industry 4.0, technologies for smart factories are becoming more important. A Manufacturing Execution System that can improve productivity and help decision making by monitoring production plants in real-time is one of the key technologies for smart factories. The application of digital twin technology for more accurate monitoring technology is also an important issue. However, digital twin implementations require an integrated infrastructure that can integrate facility data from multiple manufacturers. Therefore, this paper designs and develops a visualization program that can verify real-time information of facilities using data collection system based on international standard protocol for heterogeneous collection and monitoring of facility data. This allows a factory to consolidate equipment data from multiple manufacturers and to view them in real-time.

Design of Automatic Inspection System for Maintenance of Unmanned Monitoring Facility (무인감시설비 유지보수를 위한 자동점검시스템 설계)

  • Moon, Chaeyoung;Kim, Semin;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.515-517
    • /
    • 2018
  • Access to public facilities such as substations, dams and railway facilities is strictly controlled, and unmanned surveillance equipment has been introduced and operated recently due to the development of IT technology and the government's cost reduction policy. However, if an unmanned surveillance system is broken, surveillance space, information leakage caused by intruders, and damage to facilities may occur. Also, it is necessary to check periodical visit by the manager in order to check the surveillance facilities, which causes additional management costs. In order to solve this problem, we designed a system to check the operation status of the unmanned monitoring facility in real time, attempt to recover automatically when a problem occurs, and notify the administrator of the problem. The designed system consists of an NVR that receives and judges information such as image, sound, and lighting condition, and a control device that detects and restores the state of the unmanned monitoring facility. The system proposed in this paper is expected to contribute to the improvement of the economic efficiency due to the minimization of surveillance space due to the failure of the unmanned monitoring facility and the reduction of the inspection cost.

  • PDF

Implementation of Real-time Power Facility Monitoring System Using WSN (무선 센서 네트워크 기술을 이용한 전력 설비 실시간 감시 시스템 구현)

  • Kim, Young-Il;Cho, Seon-Ku;Yi, Bong-Jae;Song, Jae-Ju;Shin, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.488-490
    • /
    • 2006
  • In the electric power industry, It is important that the supply of energy must always be guaranteed. To satisfy these requirements, various forms of technologies are needed, such as RFID tag, reader, sensor network, middleware and so on. WSN (Wireless Sensor Network) technologies of the electric power industry are in the early stage and there is no clear guideline for developing electric facility management system using WSN. Relevant experience is limited, the challenge will be to derive requirement from business practice and to determine whether it is possible or not. To explore this issue, we focus on researching and field test of prototype system in Korea Electric Power Corporation (KEPCO). In this paper we describe requirement from power industry. And we introduce design and implementation of the power facility monitoring system.

  • PDF

A Position Control of BLDC Motor in a Rail Guided System for the Un-maned Facility Security (무인 설비 감시용 레일 가이드 구동장치에서 BLDC 전동기의 위치 제어)

  • Bae, Jong-Nam;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.223-230
    • /
    • 2017
  • A low-cost BLDC motor with hall sensor is used to drive the position control of a facility security monitoring system in this paper. Low measurable frequency of the hall sensor signal in low-speed regions results in difficulty in obtaining accurate speed detection and position control. To improve system control performance, we propose a variable gain of position controller and stop mode control scheme according to the motor speed and error position with pre-set deceleration time. The proposed stop mode control scheme is activated around the stop position to forcibly move the BLDC motor to the stop position in low speed. In the proposed stop mode, the motor current is controlled by the actual speed with the reference rotating angle. The control performance of the proposed position control is verified through experiments at the actual rail guided facility security monitoring system.

A study on the Alarm Processing System for Elevator Facility using Neural Network at Apartment (공동주택에서 신경 회로망을 이용한 승강기 계통 경보처리 시스템 개발 연구)

  • 홍규장;유건수;홍성우;정찬수
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.92-99
    • /
    • 1997
  • This paper proposed a control method to improve the efficiency of monitoring method by applying the nural network for an alarm processing method(APM)in an elevator facility of apartment complex. This APM is based on the cumulative generalized delta rule of backpropagation in neural network.It was used to infer the minimum alarms among multi-fired alarms, and then the inferred alarm can be dis¬played maintenance information of facility by using a pre-defined troubleshoot knowledge base. For validating the proposed monitoring method of this thesis, simulation results are compared with the operation of existing monitoring system and the way of alarm processing. The simulation method used to the three case of virtual scenario. As comparison results, a proposed method in this paper could be proved the applied possibility of an neural network and the performance in fields of facilities maintenance.

  • PDF

Development of Displacement Measuring Sensor Module to Monitoring About Variation and Distortion for Bridge Infrastructure at Wireless Communication Environmental (교량구조물의 구조적 변형을 측정하는 무선통신기반 변위센서모듈 개발)

  • Ryu, Seung-Ki;Moon, Hak-Yong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.87-95
    • /
    • 2010
  • Lots of bridge structure generated the change of outward formation according to durability capability and decrepitude by long use. Especially, in case of the typhoon, snowing and earthquake is going to make rapidly more worse formation about the old structural facilitys. Also, outward formation by irregular and micro-distortion in bridge structure could not easily checked by normal diagnostics method. As a result, performance-capability of structure facility is getting to make a decline in standard of structure performance. Recently, real-time monitoring technology by wireless environment go into the study of irregular movement for structure facility. This paper presents the development of sensor to displacement checking about bridge structure. Sensing method of developed sensor put bring into the gyroscope technology using the acceleration speed and angular acceleration speed. This paper also will simulated to verified the monitoring capability of developed sensor against random vibration, frequency and distortion in simulated equipment.

A Study on the Monitoring Evaluation of Elementary School Complex Facilities - Focusing on Elementary Schools in Seoul - (초등학교 복합화시설 모니터링 평가연구 - 서울시 초등학교를 중심으로 -)

  • Mok, Jeong-Hun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.5
    • /
    • pp.3-10
    • /
    • 2009
  • The purpose of this study is to provide an remodification method for elementary school complex facilities in Seoul Metropolitan city. This study analyzes the questionnaire survey for 568 entire elementary schools and the questionnaire survey for school facility complex project operated 44 elementary schools. Then the result of this study was deduced from the comparison between the 568 entire survey data and 44 survey data in terms of the cognition of school facility complex project, the required type of facility and the problems of complex facility maintenance and operation. Four major findings were revealed as the result of research. First, there is a very high agreement with the school facility complex projects. Second, it was need that the process of planning and design was remodified to enhance participation of parents of students and local residents for selecting an appropriate complex facility. Third, education environment and student safety should be protected from any other school facility complex environments. Fourth, an agreement and regulation is needed for more effective maintenance and operation of school complex facilities.

A Case Study on Smart Plant and Monitoring System Implementation of Venture Company for Auto Parts (자동차부품 벤처기업 스마트공장 및 모니터링 시스템 구현 사례연구)

  • Han, Jae Hun;Lee, Deok Soo;Park, Roh Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.5
    • /
    • pp.29-37
    • /
    • 2017
  • In this study, real-time monitoring is carried out in the factory site for product quality control such as improvement of productivity through facility automation, improvement of product quality, improvement of factory environment, check of facility maintenance status and check of product defect, And to establish a smart factory for the purpose of protecting the personal environment of the worker. The company is an auto parts company located in the province. The main research content is development of automation and monitoring system of oil filter clipping necessary for smart factory. Smart factory oil filter clipping automation is divided into electric air parts, solenoid valve and other parts processing process. Smart factory quality inspection monitoring system is implemented by server PC and S / W, client software, Operator PC, operating program, and input terminal application. This research data is expected to be very useful data for the auto parts venture companies that are promoting smart factories.

  • PDF

A Study on the Office Environmental Design of Monitoring Center (모니터링 센터의 사무 환경 디자인에 관한 연구)

  • 김형년
    • Korean Institute of Interior Design Journal
    • /
    • no.33
    • /
    • pp.46-53
    • /
    • 2002
  • The development of data communication and network technology has brought a change to various communications through the internet. Regarding the stable internet service, corporations and Individuals came to require an internet data center in which there is computer equipment and network devices available 24 hours everyday. The internet data center is now on a large scale in its structure and facility, suitable for the internet environment that is under development in various dimensions, and effective for task support, stable facility, capable of space expansion and flexibility, and easiness in ease of maintenance and management, etc. The monitoring center of the data center which is one of the core facilities in the center, special space elements and functions as well as a function of task space are to be put into consideration additionally. This study was to present a proposal for the space elements and environmental design of a monitoring center, which could create an efficient and comfortable room.