• 제목/요약/키워드: Exposure time variation method

검색결과 31건 처리시간 0.025초

Photographic Color Reproduction Based on Color Variation Characteristics of Digital Camera

  • Kim, Ui-Seong;Lee, Jong-Min;Kim, Yong-Min;Park, Ki-Tae;Moon, Young-Shik
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권11호
    • /
    • pp.2160-2174
    • /
    • 2011
  • In this paper, a new technique for color reproduction based on color variation characteristics of digital camera under a dim light condition is proposed. Generally, photographers should adjust a camera exposure properly for obtaining an image with real color tone of subjects. Thus, in case of taking a picture under a dim light condition, the exposure time of a camera has to be relatively longer than the one under a bright light condition. Although images with real color tone of the subject are obtained, the images may get blurred due to the shaky hands of photographer holding the camera. In order to avoid the blur effect, an input image is captured from a camera set as a short exposure time under a dim light condition. Then we propose a method to reproduce color tone of the dim input image. To this end, color variation characteristics which represent color variations of a digital camera are first extracted by analyzing the Macbeth color checker images taken under various exposure values. Then, a color reproduction is performed by an estimation based on the color variation characteristics. Experimental results have shown that the proposed method has achieved better performance of color reproduction, compared with existing methods.

디지털 홀로그래픽 간섭계와 PIV를 이용한 Hele-Shaw Cell 내부 열유동 해석 (Diagnosis of HSC Convective Flow Using a Digital Holographic Interferometry and PIV System)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.493-499
    • /
    • 2004
  • Variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasi-steady variation of temperature field, two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves were eliminated effectively using a digital image processing technique. The reconstructed images are clear, but transient flow cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

Statistical Modeling of the Pretilt Angle Control in Nematic Liquid Crystal using In-situ Photoalignment Method on Plastic Substrate

  • Kang, Hee-Jin;Lee, Jung-Hwan;Yun, Il-Gu;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권3호
    • /
    • pp.145-148
    • /
    • 2006
  • In this study, the response surface modeling of the pretilt angle control using in-situ photoalignment method with oblique UV exposure .on plastic substrate is investigated. The pretilt angle is the main factor to determine the alignment of the liquid crystal display. The response surface model is used to analyze the variation of the pretilt angle on the various process conditions. Heating temperature and UV exposure time are considered as input factors. The liquid crystal (LC) pretilt angle increased with increasing heating temperature and UV exposure time. The analysis of variance is used to analyze the statistical significance and the effect plots are also investigated to examine the relationship between the process parameters and the response.

어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가 (Temporal Variation of Indoor Air Quality in Daycare Centers)

  • 김윤지;이세원;반현경;차상민;김근배;이기영
    • 한국환경보건학회지
    • /
    • 제43권4호
    • /
    • pp.267-272
    • /
    • 2017
  • Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.

정류방식에 따른 장치의 정확도와 출력 파형의 비교 (Comparison of Accuracy and Output Waveform of Devices According to Rectification Method)

  • 이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

다중조사 복셀 매트릭스 스캐닝법을 이용한 이광자 중합에 의한 마이크로 3차원 곡면형상 제작 (Fabrication of Three-Dimensional Curved Microstructures by Two-Photon Polymerization Employing Multi-Exposure Voxel Matrix Scanning Method)

  • 임태우;박상후;양동열;공홍진;이광섭
    • 폴리머
    • /
    • 제29권4호
    • /
    • pp.418-421
    • /
    • 2005
  • 본 연구에서는 나노/마이크로 소자 및 MEMS 제작에 활용가능하고 또한 수십 마이크로미터 크기의 3차원 곡면을 가진 형상을 제작하기 유리한 이광자 광중합을 이용한 다중조사 복셀 매트릭스 스캐닝법(multi-exposure voxel matrix scanning method)에 의한 나노 복화공정을 개발하였다. 이 공정을 통하여는 높이에 따라 14가지의 색을 가진 등고선으로 표현된 3차원 자유곡면 형상을 적층방식이 아닌 단일 층으로 3차원으로 제작할 수 있다. 여기서 수광각도가 1.25인 집광렌즈를 사용하여 레이저의 조사시간에 따라 1.2 um에서 6.4 um까지 변하는 복셀의 높이 차이를 이용하여 3차원 곡면 제작이 가능하다. 본 연구의 유용성을 검토하기 위하여 몇 가지 3차원 곡면형상을 초미세 입체 패터닝 공정에서 사용하는 일반적인 적층방식을 사용하지 않고 단층으로 제작하여 시간을 단축하였다.

간접촬영용 X-선 발생장치 성능 평가 (An ability test for the use of indirect radiographic unit)

  • 임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권4호
    • /
    • pp.37-41
    • /
    • 2004
  • 목 적 : 측정을 통한 장치의 성능관리 평가로 임상실무에서의 능력배양과 정확한 관전압, 조사시간, 출력선량을 측정하는 기술을 익히고 병원에서 사용 중인 간접촬영용 X-선 발생장치 성능현황을 파악하기 위함이다. 재료 및 방법 : 관전압, 조사시간, 출력선량 측정기를 이용하여 10개 대학병원 간접촬영용 X-선 발생장치(원내,외 각 10대)를 이용하였다. 결 과 : 관전압 정확도 시험 PAE 판정에 의해 부적합한 간접촬영기는 3대가 나왔으며, 조사시간의 정확도 시험에서는 2대, 또한 조사선량의 재현성 시험에서도 조사선량에 대한 변동계수를 계산한 결과 3대가 나왔다. 3가지 성능검사에서 원외(이동차량)의 부적합한 간접촬영기는 5대, 원내는 3대로 원외(이동차량)의 간접촬영기가 원내보다 부적합한 것이 높게 나타났다. 결 론 : 간접촬영기의 성능을 일정하게 유지함으로서 방사선 피폭경감, 화질관리, 재촬영 감소 등에 의해 환자에게 양질의 의료서비스를 제공할 수 있는 여건을 마련할 수 있을 것이다. 따라서 정기적인 성능검사가 필요하다고 사료된다.

  • PDF

RCP 시나리오에 따른 남해안 어업 및 어종의 기후변화 노출 분석 : 수온 변동을 대상으로 (An Analysis on the Climate Change Exposure of Fisheries and Fish Species in the Southern Sea under the RCP Scenarios: Focused on Sea Temperature Variation)

  • 김봉태;이준수;서영상
    • 수산경영론집
    • /
    • 제47권4호
    • /
    • pp.31-44
    • /
    • 2016
  • The purpose of this study is to analyze the climate change exposure of fisheries and fish species in the southern sea of Korea under the RCP climate change scenarios. The extent of exposure was calculated through weighted sum of the sea temperature forecasted by National Institute of Fisheries Science, and the weight were obtained from the time-space distribution of each fisheries or species, based on the micro-data for the fishing information reported by each fisherman. Results show that all the exposed sea temperature of RCP8.5 is higher than that of RCP4.5 in year 2100 as well as in near 2030, therefore it is thought to be very important to reduce the GHG emission even in the short term. The extent of exposure was analyzed to be comparatively high especially in the fisheries such as anchovy drag nets and species like cod, anchovy and squid. Meanwhile the method of this study is considered to be excellent to obtain the accurate extent of exposure under RCP scenarios, and therefore it is applicable on assessing the vulnerability of climate change in fisheries.

광자결정 제작을 위한 홀로그라피 공정 연구 (A Study on the Holographic Process for Photonic Crystal Fabrication)

  • 여종빈;윤상돈;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.726-730
    • /
    • 2007
  • Two dimensional photonic crystals (2D PCs) have been fabricated by a double exposure holographic method using a He-Cd laser with a wavelength of 442nm. The arrays of the 2D PCs exhibit variable lattice structures from square to triangle according to a change of rotating angle $({\gamma})$ for double exposure beams. In addition, the period and filling factor of PCs as well as the forms (dot or antidot) could be controlled by experimental conditions. $A l.18-{\mu}m-thick$ resist was spin-coated on Si substrate and the 1st holographic exposure was carried out at incident angle $({\theta})$ of $11^{\circ}$. Then the sample was rotated to ${\gamma}=45^{\circ}{\sim}90^{\circ}$ and the 2nd holographic process was performed at ${\theta}=11^{\circ}$. The variation of diffraction efficiency during the exposure process was observed using a He-Ne laser in real time. The images of 2D PCs prepared were analyzed by SEM and AFM. We believe that the double holographic method is a tool suitable to realize the 2D PCs with a periodic array of large area.