A Study on Developmemt of Heat-Emission Prevention Device for SSR (무접점스위치(SSR) 발열 방지 장치 개발에 대한 연구)

  • Lee, Man-Soo;Kim, Jun-Yong;Kim, Jin-Bae
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.25-30
    • /
    • 2019
  • Electric of using in daily life is always exposed to risk of electrical fire and electric shock. Only degree of risk is different, there is no risk free electrical product. Generally, the higher voltage, the risk of electric shock is high. The much electric current, the risk of electrical fire is high. But, we can't help using electric because of risk and we effort to reduce the risk of electrical fire and electric shock. This study deal with the fire prevention generated on heating equipment using SSR for current.

An analysis of the Liquefied Petroleum Gas Usage and Risk Factor in the Camp Site (야영장 내 액화석유가스 사용실태 및 위험요소 분석)

  • Lee, Duk-Gwon;Lee, Seung-Kuk;Lee, Yeon-Jae;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.89-94
    • /
    • 2016
  • The number of camping population and sites are rapidly increasing with to the expansion of camping culture and the advancement of leisure culture. It is necessary to develop an effective strategy of safety management, as a lot of accidents occur due to the increase of population and sites for camping. Particular attention needs to be paid for accident prevention in the increasing accidents of explosion awing to the overheating of bytane gas, and carbon monoxide poisoning due to the use of non-ventilated areas. In this study, the direction of safety management strategy is analyzed by a survey and analysis of risk factors in campsite about gas facilities and gas appliances in camp site. Accordingly, some directions are suggested. Conclusively, it is expected that the results of this study could help to improve efficiency management for camping.

The Survey of Domestic and Foreign for On-Line Monitoring System at Low Voltage Facilities (저전압 전기설비의 온라인 감시시스템 구축을 위한 국내외 실태조사)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.75-81
    • /
    • 2007
  • In this paper, the survey and the analysis of domestic and foreign for on-line monitoring system at low voltage facilities example for value added service about electrical safety were executed. According to survey, in Japan, they are executing the on-line electrical facilities monitoring in based on IT basic law for the information of society construction and not only electrical safety but also value added service such as alarm for earthquake, security are being done. In USA and Europe using power line communication(PLC), the on-line observation and building district management service were being realized. Observing the domestic case, electrical safety related with service such as distribution panel product incorporating load management and leakage current measurement was being executed in some companies. From the survey, it is necessary to improve on the law and the system for market activity in domestic.

An Investigation of Health and Safety Measures in a Hydroelectric Power Plant

  • Acakpovi, Amevi;Dzamikumah, Lucky
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.331-339
    • /
    • 2016
  • Background: Occupational risk management is known as a catalyst in generating superior returns for all stakeholders on a sustainable basis. A number of companies in Ghana implemented health and safety measures adopted from international companies to ensure the safety of their employees. However, there exist great threats to employees' safety in these companies. The purpose of this paper is to investigate the level of compliance of Occupational Health and Safety management systems and standards set by international and local legislation in power producing companies in Ghana. Methods: The methodology is conducted by administering questionnaires and in-depth interviews as measuring instruments. A random sampling technique was applied to 60 respondents; only 50 respondents returned their responses. The questionnaire was developed from a literature review and contained questions and items relevant to the initial research problem. A factor analysis was also carried out to investigate the influence of some variables on safety in general. Results: Results showed that the significant factors that influence the safety of employees at the hydroelectric power plant stations are: lack of training and supervision, non-observance of safe work procedures, lack of management commitment, and lack of periodical check on machine operations. The study pointed out the safety loopholes and therefore helped improve the health and safety measures of employees in the selected company by providing effective recommendations. Conclusion: The implementation of the proposed recommendations in this paper, would lead to the prevention of work-related injuries and illnesses of employees as well as property damage and incidents in hydroelectric power plants. The recommendations may equally be considered as benchmark for the Safety and Health Management System with international standards.

A Study on the Electrical and Heat Generation Characteristics of an Induction Motor under Restrained Operation (유도전동기의 구속운전에 따른 전기 및 발열 특성 연구)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.1
    • /
    • pp.25-33
    • /
    • 2023
  • In this study, we determined the failure rate and fire status of electric motors widely used in domestic and industrial devices and analyzed the associated fire risks by identifying the electrical and temperature characteristics of electric motors under the normal and restrained operation modes in industrial sites and laboratories. A 2.2kW motor used for driving a conveyor during the vulcanization process in a rubber product manufacturing plant was employed as the study object and was exposed to a high- temperature environment as this motor is widely used in industrial sites. The current amplitude was 4.45-4.50 A during normal operation and 38.2-41.5 A during restrained operation due to the pinching of products and semi-finished products (i.e., 8.5 times higher than that during normal operation). The leakage current amplitude was 0.33 mA during both operation modes. The temperature of the workplace in summer was 42.38℃, indicating a poor environment for the installed motor. In the laboratory, the current and temperature of the coil inside a 3.7kW motor were measured under the restrained operation mode as performing measurements of the coil inside the motor in industrial sites is challenging. The current amplitude during normal operation was 3.5 A, whereas that during restrained operation for 30 s was 51.7-58.6 A, which is 14.8-16.7 times higher than that of normal operation. Moreover, the temperature of the motor coil increased from 22.9℃ to 101℃. Based on the experimental data, we derived the temperature increase formula according to the restrained operation time by performing a regression analysis and verified the time at which the temperature exceeded the stipulated limit for the insulation grade. The findings presented in this paper can be utilized to establish fire-prevention measures and perform safety management of motors of the same type or with a similar capacity.

A Study on Improvement of Safety Management in Subcontractor through Process Safety Management (공정안전관리를 통한 도급업체 안전관리 강화에 관한 연구)

  • Lee, Joo Yeob;Lee, Keun Won;Kim, Kyu-Jung;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.15-21
    • /
    • 2015
  • Looking at the large and small fire, explosion, or release accidents that occurred recently, we can see that the accident of subcontractor workers has been increased in the contractor workplace while a harmful or dangerous maintenance works. In this study, the actual status of subcontractor's safety management was examined by using the questionnaire to the contractor who submitted the process safety report. In order to improve the safety management of subcontractors, the responsibility and rational role-sharing between the contractors and subcontractors were reviewed. Also, Providing safety and health information and worker protection measures during maintenance were investigated. The results of this study can be used to help strengthen and improvement safety management of the subcontractor at the time of a hazardous or dangerous works. In addition, it will be utilized to reduce industrial accidents and to build mutual cooperation relationship between contractor and subcontractor.

Amber Information Design to Keep Safety-Driving Under Road Structure at Local-Scale Geographic (국지지역 도로 기반 시설에서 안전운전을 위한 경보 정보 설계)

  • Park, Jung-Chan;Hong, Gyu- Jang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.48-55
    • /
    • 2009
  • In order to keep safe driving conditions under road networks, there are several formations such as road structure, road surface condition, traffic occupancy and supplement of an accurate information of traffic status ahead To support safe-driving on each road formation, each formation is supplied with various information to help the driver. However, in some cases like rapid status change at local-scale geography, traffic information systems often displays insufficient information because of the lack of information correlation. In order to accurately aware the driver, all road formation must be in sync. It is important to supply accurate information to the driver because this information directly impacts the drivers on the road. This paper discusses the amber information to keep the least safety driving over road formations including tunnels and bridges. This paper also will propose the informations for safe-driving conditions, information linkage on the road and rule-base safety information, as ITS technology, being displayed for all drivers under the worst weather conditions.

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

A Study of the Irradiation Environment Effects on the Electrical Properties of Ethylene Propylene Rubber (방사선 조사 환경에 의한 에칠렌 프로필렌 고무의 전기 특성에 관한 연구)

  • 이성일
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.2
    • /
    • pp.187-200
    • /
    • 2000
  • The charge and discharge current in EPR(Ethylene Propylene Rubber), which were irradiated with the radiant capacity of 0~600 [kgy/h], have been measured in order to investigate the influence of the atmosphere (oxygen, air and vacuum) on electrical properties. It has been shown that the charge and discharge current increase as the amount of radiant capacity increases in air and vacuum atmosphere. This electrical property degradation can be speculated due to that the C=O radicals or impurities, which comes from during shaping process, may act as dipoles. On the other hand, the charge and discharge current are shown to be higher in the amount of 1[kgy/h] than these in 10[kgy/h] in air atmosphere, because the charge and discharge current can be increased as the exposure time is extended with slower rate. Under the same amount of irradiation, the charge and discharge current in oxygen atmosphere are shown to be higher than those in vacuum. This is possibly due to that the main chain can be broken by oxidation when it is exposed to the $\gamma$ -rays.

  • PDF

Local Installation Device Models for Remote Electrical Safety Monitoring of Electrical Facilities for General Use (일반용 전기설비의 원격 전기안전 감시를 위한 수용가 설치 장치 모델)

  • Jeon, Hyun-Jae;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.101-107
    • /
    • 2007
  • In order to introduce remote monitoring system for effective safety management of electrical facilities for general use, which the most of electrical fires and non-inspection problems due to absence are generated development of local device model considering cost and installation is requested. This paper presents local device models for remote electrical safety inspection of electrical facilities for general use and in order to rational model according to installation place of electrical facilities for general use, compare and analysis cost, installation and communication method of local device models. The results show that rational model for remote safety inspection of electrical facilities located in houses, which occupy the must of electrical facilities for general use, is to give safety monitoring ability to low voltage remote meter reading(or automatic meter reading: AMR).