• 제목/요약/키워드: Electrical Pole

검색결과 1,094건 처리시간 0.045초

보조 슬롯법에 의한 D.C Brushless Motor의 토오크특성 개선에 관한 연구 (A Study on the Improvement of Torque Characteristics of D.C Brushless Motor by Auxiliary Slot Method)

  • 임달호;김생수;손영규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.83-86
    • /
    • 1988
  • In all sorts of primary factor which produce torque ripple of d.c brushless motor cogging torque which is generated from relation between permanent magnet rotor and salient pole cannot controled by external control system. So in this paper cogging torque is analysed by simple method in which slot fuctuion is introduced. And for reducing counterplan of cogging torque d.c brushless motor which plot auxiliary slot by inequality interval is proposed. Thus the quantitative torque characteristics of new motor which designed by this method is analysed by F.E.M and validity of this new design is proved.

  • PDF

X-대역 단일 주파수 신호에 의한 회전물체의 영상재현 (Image reconstruction of rotating objects using X-band CW signal)

  • 서경환;신성윈;라정웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.377-382
    • /
    • 1987
  • To obtain a high resolution microwave images, back scattering microwave fields from one, two, four poles on a rotating object is measured. A computation algorithm to reconstruct these poles images from measured data is programed. The program is tested for these poles on a rotating object for different frequency intervals in the X-Band. The more frequency data yield the reduction of side lobe level. The reconstructed image for the two pole objects having the diameter of 1cm and separated by 1 lamda, 2 lamda (lamda-3.75 cm) from the measured data is shown. And, the image of two objects having the different reflectivity coefficient from the measured data is also shown and it assumes that this reconstructing algorithm from the measured angular spectrum provides quite accurate images.

  • PDF

초성파찰음의 음소분류에 관한 연구 (A Study on the Phonemic Segmentation of an Initial Affricate)

  • 김기운;이기영;배철수;최갑석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.33-36
    • /
    • 1988
  • In this paper, the starting point of affricate is detected from the first predictor coefficient of a 12-pole linear predictive coding (LPC) analysis and phonemic segmentation is done through measuring short time energy and zero crossing rate. By this segmentation method, the duration of an aspirate can be mearsured in order to detect an aspirate or not.

  • PDF

유한요소법에 의한 삼상유도전동기의 자속분포해석에 관한 연구 (A study on the magnetic flux distribution of 3-phase 4-pole induction motor by finite element method)

  • 임달호;현동석;임태빈
    • 전기의세계
    • /
    • 제30권4호
    • /
    • pp.219-226
    • /
    • 1981
  • The magnetic field distribution in saturable iron part of electromagnetic energy conversion divices is defined by the nonlinear quasi-Poisson enquation that is described the electromagnetic field characteristics and satisfied the natural boundary condition. The solution of this equation is obtained by minimizing an energy functional by means of trial function that defined in triangular subregion of two-dimensional field region. As a result, the accuracy of the machine design is increased by use of its solution. In this respect, this study is developed the basic theory to analyze the magnetic flux distribution in saturable iron part and air gap of induction motor that its secondary part is short circuit by the variational principle, the minimized theory of energy functional, the application of F.E.M., and treatment of computer. As theoritical data compared with the practics, the validity of the theory in this study is supported by experimental findings.

  • PDF

ZVT 풀 브리지 DC/DC 컨버터의 병렬 운전 및 제어기 설계에 관한 연구 (A Study on the Parallel Operation and Control Loop Design of ZVT-Full Bridge DC/DC Converter)

  • 배진용;김용;윤석호;장성원;이규훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.324-328
    • /
    • 2001
  • This paper presents parallel operation and control loop design of ZVT(Zero Voltage Transition) Full Bridge DC/DC Converter. At parallel operation of ZVT Full Bridge Converter, dynamic current shared inductor devides the same current of unit converter and ZVT circuit and aids to high efficiency in the system. Base on the modeling of ZVT. Full Bridge Converter, the control loop is designed using a simple two-pole, one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system and open loop system is carried out and the superiority of the dynamic characteristics is verified through the experiment with a 2kW, 50kHz prototype converter.

  • PDF

전력자동화서비스를 위한 광네트워크 설계 및 모뎀개발 (The Development of the Optical Network for the Automation Systems in Electric Power Companies)

  • 김명수;현덕화;조선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2543-2545
    • /
    • 2002
  • There are many applicable services such as remote metering, load control, distribution line automation, Pole transformer Monitoring having their own networks in the electric power company. The application of the optical network technology as the back-born network to the Automation Systems in KEPCO is potentially beneficial in reliability, speed, and expandability. The 1-core and 2-core optical modems were developed and used by the Distribution Automation System. But, They had some disadvantages and advantages. So, We designed the new optical modems applied each advantages. This paper presents some of design efforts and test results for the multi-channel optical modem at KRPRI.

  • PDF

발전기 운전중 회전자 계자권선의 단락 진단기법에 관한 연구 (Shorted-Turn Detction Techniques for Generator Rotor)

  • 이영준;김희동;빅종정;주영호;조지원;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1721-1724
    • /
    • 1998
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas. turbine generator #4. The test was conducted using a permanent flux probe and digital oscilloscope. The flux probe installed in the generator air gap, senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a waveform analysis technique that can identify the pole location, slot number, and number of shorted-Turns with each slot.

  • PDF

상태관측기를 이용한 자기부상시스템의 부상제어 (The Levitation Control of Maglev using State Observer)

  • 성호경;이종무;조정민;조흥제;김동성;남용윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1126-1127
    • /
    • 2006
  • Being controlled by a pole placement, levitation system should need many sensors such as measure air-gap, velocity, acceleration, and so on. However, these sensors have observational errors by changed temperature. This paper proposed a output compensated command tracking controller for reducing the error and reducing sensors. Simulation results will be provided to show the validity of the proposed scheme.

  • PDF

새로운 양방향 ZVS PWM SEPIC/ZETA 컨버터 (New Bidirectional ZVS PWM SEPIC/ZETA Converter)

  • 박성대;팽성환;김인동;노의철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.933-934
    • /
    • 2006
  • 본 논문에서는 새로운 양방향 ZVS PWM Sepic/Zeta 컨버터를 제안한다. 제안한 컨버터는 PWM 제어가능한 컨버터로서 입력과 출력전압의 극성이 같은 비반전 컨버터의 특징을 지니며 DC 전압의 전달함수가 양방향 모두 M=D/(1-D)로 동일하다. 또한 각방향으로 전력전달시 다이오드와 병렬로 연결된 MOSFET가 다이오드의 'ON'시 동시에 'ON'되어 Sychronous Rectifier로 동작하므로 도통손을 저감하였으며, Auxiliary Resonant Commutated Pole를 사용하여 저감된 스위칭 손실을 갖는 특성을 지니고 있다. 또한 Transformer 버전이 존재하므로 입력과 출력사잉에 전기적 절연을 필요로 하는 실제응용에 유용하게 사용할 수 있다.

  • PDF

단상 SRM에 사용되는 전자석 기동 장치 (Electromagnet Starting Device used in the Single-Phase SRM)

  • 김준호;이은웅;이종한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.813-814
    • /
    • 2006
  • The squirrel case induction motor has widely used in the driving of the blowers but it is low efficiency and hard to control. So, the damper is used for the control of a flow and it cause to low the driving efficiency. Our laboratory has proposed the single-phase SRM(switched reluctance motor) for driving blowers. It has salient pole structure and can be reduced a number of semiconductors than three-phase SRM. But it can not be starting by itself and has heavier torque ripple than three-phase SRM. For self-starting the single-phase SRM is required the starting device which place the rotor at the rising inductance slope. On this paper, the electromagnet starting device is designed to generate the starting torque and to fix the rotating direction of the single-phase SRM which is fabricaed to use a blower.

  • PDF