Improved Metal Object Detection Circuits for Wireless Charging System of Electric Vehicles

  • Sunhee Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권8호
    • /
    • pp.2209-2221
    • /
    • 2023
  • As the supply of electric vehicles increases, research on wireless charging methods for convenience has been increasing. Because the electric vehicle wireless transmission device is installed on the ground and the electric vehicle battery is installed on the floor of the vehicle, the transmission and reception antennas are approximately 15-30 cm away, and thus strong magnetic fields are exposed during wireless charging. When a metallic foreign object is placed in the magnetic field area, an eddy current is induced to the metallic foreign object, and heat is generated, creating danger of fire and burns. Therefore, this study proposes a method to detect metallic foreign objects in the magnetic field area of a wireless electric vehicle charging system. An active detection-only coil array was used, and an LC resonance circuit was constructed for the frequency of the supply power signal. When a metallic foreign object is inserted into the charging zone, the characteristics of the resonance circuit are broken, and the magnitude and phase of the voltage signal at both ends of the capacitor are changed. It was confirmed that the proposed method has about 1.5 times more change than the method of comparing the voltage magnitude at one node.

표준편차와 확률분포를 이용한 모의전기설비에서 사고징후 검출 (Detection of Indication of Electric Accident in Simulated Electric Equipments Using Standard Deviation and Probability Distribution)

  • 지승욱;옥경재;김시국;이춘하
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.11-16
    • /
    • 2009
  • 본 논문은 전기설비에서 사고 발생 징후를 검출하기 위한 방법을 기술하고 있다. 실험을 위해 전기설비의 부하는 백열전구로 구성하였고, 사고는 전기설비의 일부에 KS C IEC(Korea Standard C International Electrostatic Commission) 60112에 따른 내트래킹 시험장치를 연결하여 모의되었다. 모의사고는 정상상태에서 방전진전과 탄화형성 과정을 거쳐 트래킹파괴에 이르게 된다. 전기설비로부터 사고 징후 검출을 위해 전류 모니터를 이용하여 전기설비 전체의 전류를 측정하고 이를 분석하였다. 그 결과, 전류 파형의 특정 영역에서 사고의 진행 정도가 클수록 전류 펄스의 크기가 커지고, 발생 빈도도 증가하였다. 특히 전류파형에 대한 표준편차와 확률분포는 부하의 수와 무관하게 사고단계별로 뚜렷한 차이를 보였다.

Design and construction of a new ultraviolet sensor using CsI deposition in the ionization chamber

  • Souri, R.;Negarestani, A.;Souri, S.;Farzan, M.;Mahani, M.
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.751-757
    • /
    • 2018
  • In this article, a UV sensor that is an appropriate tool for fire detection has been designed and constructed. The structure of this UV sensor is an air-filled single-wire detector that is able to operate under normal air condition. A reflective CsI photocathode is installed at the end of the sensor chamber to generate photoelectrons in the ion chamber. An electric current is produced by accelerating photoelectrons to the anode in the electric field. The detector is able to measure the intensity of the incident UV rays whenever the current is sufficiently high. Therefore, the sensitivity coefficient of this sensor is found to be $7.67{\times}10^{-6}V/photons/sec$.

저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구 (A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line)

  • 강경원;윤명오;구선환;송영주
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.136-145
    • /
    • 2011
  • 화재발생 원인 중 가장 많은 부분을 차지하는 것 중 하나가 전기적 요인이며 이 전기적 요인 중 일정 비율 이상을 차지하는 것이 누전 지락사고이다. 이러한 누전 지락사고를 줄이기 위해 최근 국제규격인 IEC 60364-4-41을 반영한 저압전로의 지락보호에 관한 기술지침(KECG 1091-2011)이 개정되었으며 설비의 상시사용 운용 및 고장 결함 등을 회복시켜 신뢰성을 향상시키는 보전방식이 대두되고 있다. 따라서 본 논문에서는 최근 10년간의 화재발생현황을 파악하여 전기화재의 위험성을 분석한 후 일정비율 이상 차지하고 있는 누전 지락사고를 개선시키기 위한 방법으로 KECG 1091-2011의 개정사항을 검토한 다음 누전 지락보호검출의 신뢰성을 향상시키기 위한 예방보전 방식을 적용하여 시간계획보전 방식으로 정기점검제도와 내용연수제도에 대한 문제점을 나열한 후 그 해결방안을 제시하고 상태감시보전 방식으로 누설전류 통합감시 장치와 디지털 누전경보기를 제안하고자 한다.

3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정 (Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device)

  • 이문형;정재희
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

주기 신호 검출을 통한 거짓 경보 제거 기능을 갖춘 비디오 화염 감지 기법 (Video Flame Detection with Periodicity Analysis Based False Alarm Rejection)

  • 이상학
    • 한국전자통신학회논문지
    • /
    • 제6권4호
    • /
    • pp.479-485
    • /
    • 2011
  • 비디오 기반 화염 감지 기법은 입력 비디오 영상에서 화염과 비슷한 색상을 가지고 움직임이 있는 영역에 대해서 화소 단위로 화염의 특성을 가지고 있는지를 시간적, 공간적 특징 분석을 통하여 확인한다. 비디오 기반 화염 감지 기법 연구의 가장 중요한 부분 중 하나는 화염 감지 성능이 저하되지 않고 어떻게 거짓 경보의 빈도를 줄일 수 있는가 하는 것이다. 기존의 방법들은 전기 장치로 만들어진 불빛들 중에서 자동차 전조등과 같은 일반적인 움직임을 가진 전기 불빛에 의한 거짓 경보는 쉽게 제거하고 있다. 그러나 경광등, 경고등 그리고 네온사인과 같이 깜빡거림이 있는 전기 불빛은 색상과 시간적, 공간적인 특징이 실제 화염과 비슷할 경우 거짓 경보를 발생시키는 요인이 되고 있다. 본 논문에서는 경광등, 경고등 그리고 네온사인과 같이 깜빡거림이 있는 전기 불빛 화소들의 주기 신호 검출을 통하여 진짜 화염이 아님을 확인하는 거짓 경보 제거 기능을 갖춘 비디오 화염 감지 기법을 제안한다. 실험 결과 화재 감지 성능은 기존의 방법과 비슷하였으나 기존의 방법이 거짓 경보를 발생시키는 시험 비디오에서 거짓 경보가 발생되지 않음을 볼 수 있었다.

철근 콘크리트 보에서의 다기능 센서를 이용한 손상 추정법 개발 (Development of Damage Estimation Method using Sensor of Multiple Function in RC Beam)

  • 김이성;박강근;김화중
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.184-188
    • /
    • 2008
  • 콘크리트는 균열손상으로 인하여 구조적 품질이 저하되며 결국, 이는 구조물에 심각한 영향을 준다. 이러한 손상을 검사하는 방법으로 육안으로 확인하거나 비파괴 시험법을 주로 이용하고 있으며, 비파괴시험법은 다양한 센서를 이용한다. 이러한 대부분의 센서는 1축에 대한 측정을 하기 때문에 방향성이 불규칙한 균열 손상을 측정하기에는 어려움이 많다. 또한, 화재가 발생하면 이러한 센서는 사용할 수가 없다. 화재발생시 사용할 수 있는 센서는 열전대이며, 이러한 센서는 온도측정을 위해 사용되므로 화재손상으로 발생된 주요 부재 및 구조물의 변형을 측정할 수 없다. 본 연구는 3축 가속도센서와 열전대 센서의 전기 저항적 특성을 이용하여, 외력 및 화재발생으로 구조물의 손상 전과 손상 후의 안전성을 검토할 수 있는 다기능센서를 개발하기 위한 기초적 연구이다.

  • PDF

향 검지 시스템의 특성 해석 및 평가에 관한 연구 (A Study on the Properties Analysis and Estimation of Odor Detection System)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-5
    • /
    • 2009
  • 본 연구에서는 분전반의 설치 형태를 조사하였고, 향 검지 시스템의 재현 실험을 통해서 전기 재해 예방의 가능성을 확인하고자 한다. 주택용 분전반 내에 설치된 차단기는 MCCB, RCD 순서로 되어 있으나, 산업용은 혼용되고 있다. 접속이 부적절하게 된 단자대에 가진기를 이용하여 진동을 가했을 때 불꽃이 확인되었다. 단자대에 향 캡슐을 부착하여 실험한 결과, 발생한 열에 의해 캡슐이 정확하게 작동되었다. 센서의 설치 위치에 따라 검지 시간의 차이는 약 10초 이었다. 향 검지 시스템은 전기 설비 사고 예방이 가능한 것으로 판단된다. 전선의 접속부에서 이상 발열이 있을 때 과열의 상태를 관리자에게 경보해 줌으로써 사고 예방이 가능할 것으로 판단된다.

Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계 (Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function)

  • 김홍주;하판봉;김영희
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.132-139
    • /
    • 2020
  • 공기청정기에 사용되는 이오나이저 모듈은 권선형 transformer를 사용하여 방전전극인 HV+/HV-에 3.5KV/-4KV의 고전압을 공급하여 carbon fiber brush의 전계 방사에 의해 양이온과 음이온을 발생시킨다. 기존의 MCU를 이용한 이오나이저 모듈 회로는 PCB 사이즈가 크고 가격이 비싼 단점이 있고, 기존의 ring oscillator를 이용한 게이트 구동 칩은 oscillation 주기가 PVT(Process-Voltage-Temperature) 변동에 민감하고 HV+와 GND, HV-와 GND의 단락에 의한 fault detection 기능이 없으므로 화재나 감전의 위험이 있다. 그래서 본 논문에서는 7bit binary UP counter를 이용하여 PVT 변동이 있더라도 oscillation 주기를 조절하여 HV+ 전압이 목표 전압에 도달하게 한다. 그리고 HV+와 GND 사이의 단락을 검출하기 위한 HV+ short fault detection 회로, HV-와 GND 사이의 단락을 검출하기 위한 HV- short fault detection 회로와 HV+가 과전압 이상으로 올라가는 것을 검출하기 위한 OVP(Over-Voltage Protection) 회로를 새롭게 제안하였다.

EMTP를 이용한 아크 사고의 모의 (Simulation of Fault-Arc using EMTP)

  • 변성현;최해술;채종병;김철환;한경남;김일동;김영한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.850-852
    • /
    • 1996
  • High impedance fault (HIF) is defined as fault that general overcurrent relay can't detect or interrupt, Especially when HIF occur under 15 kV, energized high voltage conductor results in fire hazard, equipment damage or personal threat. Because most HIF occur arc, HIF detection using arc is to increase. Numerical arc model can be applied in an electromagnetic transients program (EMTP) to reproduce the dynamic and random characteristic of arcs for any insulator arrangement, current and system voltage. It allows the representation of any network configuration to be investigated, so the digital simulation of arc faults through air can be substitute for demanding power arc test.

  • PDF