• 제목/요약/키워드: Electric Block

검색결과 248건 처리시간 0.044초

Horizontal Stress Analysis of Electric Pole using Earth Pressure Cell from Mock-Up Tension Test (전주의 실물인장실험시 토압계를 이용한 수평토압분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제24권8호
    • /
    • pp.62-69
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. 4 anchor blocks decreased earth pressure at G.L.-0.9[m]. It is considered that 4 anchor blocks installed along 80[cm] vertically are main reason. Overall, when more anchor blocks are constructed, excavation area is large, and constructivity such as backfill is bad, therefore one anchor block would be preferred.

Lateral Earth Pressures and Displacements through Full Scaled Lateral Loading Test of Concrete Electric Pole Embedded in Ground (지중에 근입된 콘크리트전주의 실물 수평재하실험에 의한 수평토압과 변위특성)

  • Ahn, Tae-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • 제12권4호
    • /
    • pp.43-51
    • /
    • 2011
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. lateral displacements showed differences depending on location, numbers and depth of poles. The bending is generated in the upper part at the initial load, but it moved to central part as load increased. The maximum horizontal displacement decreased to 1/1.6 at -0.5m depth of anchor block and 1.3m additional laying depth of poles into ground.

Fault Diagnosis and Performance Evaluation of Auxiliary Block for Korean High-Speed Railway (한국형 고속열차 보조전원장치 고장진단과 성능평가)

  • Kim, Seog-Won;Kim, Ki-Hwan;Kim, Sang-Soo;Koo, Hun-Mo;Joo, Hyun-Wook;Han, Young-Jae
    • Journal of the Korean Society for Railway
    • /
    • 제9권5호
    • /
    • pp.612-617
    • /
    • 2006
  • As the on-board electric devices determine the performances of vehicles, production of reliable devices is important. To keep the reliability of devices constant, management of performance evaluation of the on-board devices is crucial. Because temperature has a serious effect on failures of the components of the devices, its measurement is the first step for good management. In this study, we described performance characteristics of domestic auxiliary block developed through G7 project. We measured the performances of auxiliary block during test running by the developed on-line measurement system. After we save the input real-time data from each signal of Korean High Speed Train through the network line, we can acquire necessary information through post-processing program. We verify the motor block characteristics of Korean High Speed Train by this system.

Fractal Image Compression Using QR Algorithm (QR 알고리즘을 이용한 프렉탈 영상압축)

  • Han, Kun-Hee;Kim, Tae-Ho;Jun, Byoung-Min
    • Journal of the Korean Society of Industry Convergence
    • /
    • 제3권4호
    • /
    • pp.369-378
    • /
    • 2000
  • Conventional fractal image compression methods have many problems in searching time for matching domain block. Proposed method is an improved method of Fisher's Quadtree Decomposition in terms of time, compression ratio, and PSNR. This method determines range block in advance using QR algorithm. First, input image is partitioned to $4{\times}4$ range block and then recomposition is performed from bottom level to specified level. As a result, this proposed method achieves high encoding and decoding speed, high compression ratio, and high PSNR than Fisher's Quadtree Decomposition method.

  • PDF

Ambulatory Aid Device for the Visually Handicapped Person Using Image Recognition (화상인식을 이용한 시각장애인용 보행보조장치)

  • Park Sang-Jun;Shin Dong-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제12권6호
    • /
    • pp.568-572
    • /
    • 2006
  • This paper presents the device of recognizing image of the studded paving blocks, transmitting, the information by vibration to a visually handicapped person. Usually the blind uses the walking stick to recognize the studded paving block. This research uses a PCA (Principal Component Analysis) based image processing approach for recognizing the paving blocks. We classify the studded paving blocks into 5 classes, that is, vertical line block, right-declined line block, left-declined line block, dotted block and flat block. The 8 images for each of 5 classes are captured for each block by 112*120 pixels, then the eigenvectors are obtained in magnitude order of eigenvectors by using principal component analysis. The principal components for images can be calculated using projection of transformation matrix composed of eigenvectors. The classification has been executed using Euclidean's distance, so the block having minimum distance with a image is chosen as matched one. The result of classification is transmitted to the blind by electric vibration signals with different magnitudes and frequencies.

A Comparative study about a horizontal displacement, the effect of the existing and the arch-type anchor block on concrete pole (기존 버팀대와 아치형 버팀대가 콘크리트 전주에 미치는 수평변위에 대한 비교 연구)

  • Kwon, Sin-Won;Mun, Sung-Won;Kwon, Se-Won;Park, Y.B.;Kim, Jeom-Sik;Jo, Sung-moon;Kim, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2079-2080
    • /
    • 2008
  • 본 연구는 기존 버팀대의 폭이 1,200mm로 오거크레인에 의한 기계화 시공 시 작업이 어렵고 품질이 저하되는 경향이 있어 이러한 문제점을 보완한 직경 800mm, 높이 350mm의 아치형 버팀대를 개발하여 이에 대한 기능 및 저항특성에 대한 안전성을 평가 하고자 한다.

  • PDF

A Study on the Induction Method of Transfer Function of Bond Graph using Mason's Rule (메이슨의 공식을 이용한 본드그래프의 전달함수 유도법에 관한 연구)

  • 한창수;오재응
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제6권4호
    • /
    • pp.66-75
    • /
    • 1998
  • In many case of optimal design and sensitivity analysis, obtaining of transfer function between input and output variables is a difficult and time-consuming problem. The bond graph modeling is a method that is used for making it easy to analyze complex systems composed of mechanical and electrical parts. It gives us a simple and systematic tool to get state-space equations easily. And we can obtain the transfer function graphically using bond graph and Mason's rule. This paper shows how bond graphs are converted to block diagram and how Mason's rule is applied. And the simple direct method to obtain transfer function from bond graph is introduced. As a example, induction of transfer function of electric power steering composed of mechanical and electrical parts will be done.

  • PDF

Optimal Control of Nonlinear Systems Using Block Pulse Functions (블럭펄스 함수를 이용한 비선형 시스템의 최적제어)

  • Jo, Yeong-Ho;An, Du-Su
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • 제49권3호
    • /
    • pp.111-116
    • /
    • 2000
  • In this paper, we presented a new algebraic iterative algorithm for the optimal control of the nonlinear systems. The algorithm is based on tow steps. The first step transforms optimal control problem into a sequence of linear optimal control problem using the quasilinearization method. In the second step, TPB(two point boundary condition problem) is solved by algebraic equations instead of differential equations using BPF(block pulse functions). The proposed algorithm is simple and efficient in computation for the optimal control of nonlinear systems. In computer simulation, the algorithm was verified through the optimal control design of Van del pole system and Volterra Predatory-prey system.

  • PDF

Mechanism of Wrinkle Formation on Styrene-Butadiene-Styrene Block Copolymer via Ion-Beam Irradiation (Styrene-Butadiene-Styrene Block Copolymer 위 이온빔 조사를 이용한 주름 구조 생성 메커니즘 연구)

  • Lee, Ju Hwan;Kim, Dai-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제34권2호
    • /
    • pp.130-135
    • /
    • 2021
  • Wrinkle patterns were fabricated on styrene-butadiene-styrene (SBS) block copolymer substrates using ion-beam (IB) irradiation with various intensities. The wavelength of the wrinkle pattern increased as the IB intensity was increased from 800 to 1,600 eV. IB irradiation-induced changes in the surface properties that were confirmed via physicochemical surface analyses. X-ray photoelectron spectroscopy analysis revealed chemical surface reformation due to the IB irradiation, resulting in C-O/C=O bonds after IB irradiation that were not reported before. These results indicate that the surface chemical modification caused by IB irradiation is strongly related to the surface modulus, which is important when fabricating wrinkle patterns. Furthermore, a strong IB irradiation induced a strong compressive strain; thus the size of the wrinkle pattern was increased.

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.