• Title/Summary/Keyword: EMF Strength

Search Result 27, Processing Time 0.025 seconds

The Level of Exposure to Electromagnetic Fields Strength from VDT According to the Arrangement of Working Space VDT (영상표시단말장치의 작업공간 배열에 따른 전자파 폭로 정도)

  • Han, Sangil;Lee, Sehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.146-154
    • /
    • 1998
  • This study was designed to investigate the workers' exposure level to electromagnetic field(EMF) in accordance with the VDT arrangement in the work place and distance from VDT. Author compared the exposure strength of EMF in line group(workers exposed to EMF from both front and back side) and in shielding group(workers exposed to EMF exclusively from front side). The levels of EMF at 30cm and 50cm from front side and at 30cm from back side of VDT were also measured. The result were as follows: 1. Mean distance between a monitor and a worker in shielding group ($47.7{\pm}8.7cm$) significantly longer than that in line group($44.3{\pm}7.2cm$). Strength of EMF in shielding group [$1.3{\pm}0.7V/m$ (electric field) and $18.2{\pm}11.5mA/m$ (magnetic field) were lower than in line group [$1.4{\pm}0.6V/m$ and $26.6{\pm}11.6mA/m$, respectively] at the workers' position. 2. The strength of EMF was decreased with the distance from VDT. The strength at 70cm from VDT was nearly the same as the background strength in the ordinary office rooms. 3. Working distance from 9 inch monitor was significantly shorter than that from 14 inch and wider sized monitors. 4. The strength of EMF in extremely low frequency spectrum of color monitors was higher then that of black and white monitor. 5. Metal coated filters significantly decreased the electric field strength of EMF when earth line was connected. Metallic shield was effectively decreased the EMF strength from VDT, but wooden shield was not. From the above results, line type arrangement of VDT in the work place using metallic shield at the back side of VDT, and metal coated filter to monitor with application of earth line were recommended. It is also recommended to maintain workers position to be 60cm or more distance from monitor and 140cm or more between VDTs for minimizing workers' exposure to EMF.

  • PDF

Exposure Level Analysis of EMF Strength on Human around Base Station (이동 통신 기지국 주변 전자파강도 인체 노출량 분석)

  • Kim, Hyun-Bong;Kim, Wan-Ki;Lee, Yeong-Su;Jun, Wan-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.525-533
    • /
    • 2013
  • As the number of base stations for mobile communication services rapidly grows with the development of mobile communications and the increase of radio-use devices, there are hazardous concerns raised on the possible health effects of EMF(Electro-magnetic fields) radiated from base station antennas. Since 2007, KCA(Korea Communications Agency) has been measuring the EMF on base station defined by Radio Act. This paper was studied to provide objective and accurate information that relieved anxiety of people by analyzing the measurement results on EMF strength. Also, we suggest to effectiveness and improvement of EMF measurement institution by analyzing measurement results since it was introduced on June 2007.

Effect of electromagnetic field exposure on the reproductive system

  • Gye, Myung-Chan;Park, Chan-Jin
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • The safety of human exposure to an ever-increasing number and diversity of electromagnetic field (EMF) sources both at work and at home has become a public health issue. To date, many in vivo and in vitro studies have revealed that EMF exposure can alter cellular homeostasis, endocrine function, reproductive function, and fetal development in animal systems. Reproductive parameters reported to be altered by EMF exposure include male germ cell death, the estrous cycle, reproductive endocrine hormones, reproductive organ weights, sperm motility, early embryonic development, and pregnancy success. At the cellular level, an increase in free radicals and $[Ca^{2+}]i$ may mediate the effect of EMFs and lead to cell growth inhibition, protein misfolding, and DNA breaks. The effect of EMF exposure on reproductive function differs according to frequency and wave, strength (energy), and duration of exposure. In the present review, the effects of EMFs on reproductive function are summarized according to the types of EMF, wave type, strength, and duration of exposure at cellular and organism levels.

JOINING OF THIN-WALLED ALUMINUM TUBE BY ELECTROMAGNETIC FORMING (EMF)

  • PARK Y.-B.;KIM H.-Y.;OH S.-I.
    • International Journal of Automotive Technology
    • /
    • v.6 no.5
    • /
    • pp.519-527
    • /
    • 2005
  • Recently, weight reduction of vehicles has been of great interest and consequently the use of low-density materials in the automotive industry is increasing every year. However, the substitution of one material for another is not simple because it accompanies several problems, for example, weakness in the strength and stiffness and difficulty in the joining. To overcome these problems, the structure of the automobile redesigned totoally. Aluminum spaceframe is rapidly being adopted as a body structure for accommodating lightness, stiffness and strength requirement. In aluminum spaceframe manufacturing, it is often required to join aluminum tube. However, there are few suitable methods for joining aluminum tube, so that much interest has been focused on testing suitable joining methods. Joining by electromagnetic forming (EMF) can be useful method in joining aluminum tube, which offers some advantages compared with the conventional joining methods. In this paper, joining by EMF was investigated as a pre-study for applying an automotive spaceframe. Finite element simulations and strength tests were performed to analyze the influence of geometric parameters on joint strength. Based on these results, configurations of axial joint and torque joint were suggested and guidelines for designing EMF joint were established.

A Study on Electromagnetic Field Emission and Its Effect on Electromagnetic Environment (전자파 환경의 전자기장 방출과 그 영향에 대한 고찰)

  • Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.613-618
    • /
    • 2019
  • EMF (Electromagnetic Field) is a valuable resource for living in a knowledge-based information society. The EMF is used in home appliances that make our lives easy and convenient, and in telecommunication devices such as mobile phones, personal computers, medical devices and broadcasting towers. However, the biological hazards associated with EMF exposure are also increasing in signal from telecommunication devices. Studies of the effects of EMF exposure on humans have been conducted for a long time, but it has not yet been demonstrated whether the EMF effect is harmful. In this paper, we examine the electromagnetic field emitted from various electronic devices around living and its effect.

Sensitivity Analysis of Numerical Variables Affecting the Electromagnetic Forming Simulation of a High Strength Steel Sheet Using a Driver Sheet (수치적 변수들이 배면판을 이용한 고강도 강판의 전자기 성형 해석에 미치는 영향도 분석)

  • Park, H.;Lee, J.;Lee, Y.;Kim, J.H.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.28 no.3
    • /
    • pp.159-166
    • /
    • 2019
  • Electromagnetic forming (EMF) simulations consider 3-dimensionally coupled electromagnetic-mechanical phenomenon using LS-DYNA, therefore the calculation cost is normally expensive. In this study, a sensitivity analysis in regard to the simulation variables affecting the calculation time was carried out. The EMF experiments were conducted to form an elliptically protruding shape on a high-strength steel sheet, and it was predicted using LS-DYNA simulation. In this particular EMF simulation case, the effect of several simulation variables, viz., element size, contact condition, EM-time step interval, and re-calculation number of the EM matrices, on the shape of elliptical protrusion and the total calculation time was analyzed. As a result, reasonable values of the simulation variables between the simulation precision and calculation time were proposed, and the EMF experiments with respect to the charging voltages were successfully predicted.

EMF (electromagnetic field strength)가 스퍼터된 ITO 박막의 초기 성장에 미치는 영향

  • Park, So-Yun;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.183-183
    • /
    • 2015
  • Indium tin oxide (ITO)는 넓은 밴드갭을 가지는 n-type의 축퇴 반도체로 태양전지, 스마트윈도우, 터치 센서, organic light emitting displays (OLEDs) 등에 널리 적용된다. 최근 touch screen panels (TSPs)의 높은 전기적 특성 및 고해상도 요구에 따라 고품질 ITO 박막개발의 수요도 증가하는 추세이다. 지금까지 ITO 박막의 물성 및 기계적 특성에 관한 많은 연구가 진행되어 왔지만 ITO 초박막 에서의 근본적인 물성 변화에 대한 연구는 미흡한 실정이므로, 이러한 연구는 필수적이라 할 수 있다. ITO 초박막은 광학적 특성은 우수하나, 낮은 결정성으로 인해 전기적 특성이 나쁘다는 단점을 가지며, 이러한 ITO 박막의 결정성은 초기 박막 성장과정에 많은 영향을 받는다. ITO 박막의 초기성장과정은 핵이 생성된 후(nucleation), 각각의 위치에서 성장하게 되고(growth), 합쳐지면서(coalescence) 연속적인 막을 형성 하는데(continuous), 이러한 초기 박막 성장 과정 중에 핵 생성 밀도를 증가시키고 박막이 연속적으로 되는 두께를 감소시킨다면, 더욱 더 고품질의 ITO 초박막을 얻을 수 있을 것이다. 따라서, 본 연구에서는 박막 초기 형성 과정 중 섬들이 합체되는 두께를 최소화시키기 위하여 EMF(electromagnetic field strength) 시스템을 이용하였다. EMF 시스템은 DC 캐소드에 전자석 코일을 장착하여 전자기장을 추가로 부가한 것으로, 이를 이용할 경우 스퍼터 원자가 중성상태로 기판에 도달하는 것이 아니라, 이온화되어 Vp-Vf의 차이로 가속되어 추가적인 에너지를 공급받음으로써 기판표면상에서 확산을 촉진시키므로 박막이 연속적으로 되는 임계 두께를 감소시킬 수 있는 것으로 기대된다. 실험은 실온에서 DC 마그네트론 스퍼터링법을 이용하였으며, 유리기판위에 4, 6, 8, 10, 12, 20 nm의 두께로 ITO 박막을 제작하였다. 스퍼터링 파워는 150 W (3.29 W/cm3), 작업 압력은 0.13 Pa, 기판과 타깃 사이의 거리는 70 mm였다. 각각의 두께에서 EMF 파워 0, 5, 10, 15, 20, 25, 30 W로 인가하여 박막을 제작한 후, EMF 파워에 따른 ITO 박막의 초기 성장 과정중 표면상태를 AFM (atomic force microscope) 이미지를 통하여 관찰하였다. 또한, 두께 약 8 nm에서와 20 nm일 때의 전기적 특성 및 광학적 특성을 관찰하였으며, 두 박막 모두 EMF 파워 15 W를 인가하였을 때 그 특성이 가장 향상되는 것을 확인하였다. 이러한 결과를 통하여 박막은 초기 성장이 중요하므로, 매우 얇은 두께에서 좋은 특성을 가진 박막을 제작하여야 박막의 두께를 증가시켰을 때도 좋은 특성의 막을 얻을 수 있음을 알 수 있었다. 또한, EMF 파워를 증가시킴에 따라 자장강도를 증가시키는 것과 같은 효과 즉, 플라즈마 임피던스가 감소하는 효과를 내어 증착 중 고 에너지 입자 (Ar0, O-)에 의한 박막손상이 감소한 것으로 판단된다. 따라서 적정 EMF 파워 15 W를 인가하였을때 가장 물성이 좋은 ITO 박막을 얻을 수 있었다. 즉, EMF 시스템을 이용하여 저온 공정에서 결함농도가 적은 고품질의 ITO 초박막을 제작할 수 있었다.

  • PDF

Analysis for Measured Results in EMF Strength Exposure Level under Base Station Environment for Mobile Communication (이동 통신용 기지국 환경에서 전자파 강도 노출량 측정 결과 분석)

  • Song, Hae-Zu;Kim, Soon-Young;Lee, Moon-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.601-609
    • /
    • 2010
  • This paper measured EMF strength of the duty measurement radio station(77 station) and the non-duty measurement radio station(41 station) of mobile communication base station in Jeonbuk region. As the result of measurement, it generally reveals that EMF is highly low level compare to the human protection guideline. And It is regarded as level that the national people who live close to the mobile communication base station don't have to worry about electromagnetic wave. This paper provides comparative analyses categorized by the duty measurement station and the non-duty measurement station. The results reveals that the average value and the maximum value of the non-duty measurement station preferably was higher than all the duty measurement station. It is thought that the EMF exposure strength of the national people is caused by approach of station antenna rather than antenna power. Consequently this paper suggests that standard of the antenna power(exceed 30 W), standard of antenna height(exceed 10 m) specified by Radio Regulation Act enforcement ordinance, legal basis for mobile communication base station have to be changed.

Electromagnetic fields in subways and national railway (지하철과 국철에서의 전계 및 자계)

  • Ryu, C.Y.;Nam, K.C.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.299-302
    • /
    • 1997
  • Recently, many people are interested in the electromagnetic fields(EMF), so we measured the strength of electromagnetic fields in the carriages of national railways and subways. We also measured on the platforms of national railways and subways. The strength of EMFs on the platforms of national railways was stronger than that of subway's platforms. EMF measured on the platform during railway carriage's arriving and leaving was stronger than that without carriages. The strength of the magnetic fields in the carriages of national railways was measured stronger than that of subway's carriage while national railway is run by AC while subway is run by DC. Also The strength of the subway line 8 were measured stronger two to three times than others.

  • PDF

Study on Joining Strength Improvement of Solder Joint with Pb Free Solder (Pb Free 솔더를 사용한 솔더 접합부의 접합 강도 향상에 관한 연구)

  • 신영의;김영탁
    • Journal of Welding and Joining
    • /
    • v.15 no.2
    • /
    • pp.36-42
    • /
    • 1997
  • In this paper, stability of initial strength at solder joint with lead free solders, such as Sn-In (52-48%) and Sn-Ag (96.5-3.5wt%) was studied. To obtain at solder joint with high quality, it is very important to control the temperature at the interface of solder joints. It is found that the thermal EMF (electro motive force) occurs betwee lead frame and copper pad on a substrate during reflow soldering process using heated tip. As a result of control the temperature at interface of solder joints, variation of initial strength at solder joint decreases from about $\pm40%$ to $\pm20%$, and it is realized Pb free soldering process using Sn/In and Sn-Ag solder paste.

  • PDF