• Title/Summary/Keyword: Distribution Fault

Search Result 1,024, Processing Time 0.046 seconds

Analysis on Current Limiting and Recovery Characteristics of a SFCL Dependent on Magnetic Coupling of Shunt Reactors (션트리액터의 자기결합유무에 따른 초전도전류제한기의 전류제한 및 회복특성 분석)

  • Lim, Sung-Hun;Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.277-279
    • /
    • 2008
  • The current limiting and recovery characteristics of a superconducting fault current limiter (SFCL) using shunt reactors were analyzed. Generally, the shunt reactor has a role to distribute the even voltage drop between high-Tc superconducting (HTSC) elements comprising the SFCL. However, the shunt reactors magnetically separated was not contributed to the equal voltage distribution between the HTSC elements. Through the experiments for the SFCL with both the magnetically coupled and magnetically uncoupled shunt reactors, the magnetically coupled shunt reactors were confirmed to improve the current limiting and recovery characteristics of the SFCL.

  • PDF

A Study of Fault Current Distribution Ratio with a Reduction Equipment of Sheath Circulating Current (시스전류 저감장치 적용시 고장전류분류율 검토 및 대책)

  • Hong, D.S.;Jang, T.I.;Kang, J.W.;Kim, J.S.;Yoon, H.H.;Lim, H.E.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.503-505
    • /
    • 2003
  • 본 논문에서는 방전갭을 이용한 시스 순환 전류 저감장치 보호유닛을 제안하여 SVL형식의 저감장치 보호유닛과 뇌써지시 과도특성을 비교하였으며, 또한 시스 순환전류 저감장치 보호유닛 적용시의 고장전류분류율을 검토한 결과 모든 경우에 대하여 각 접지선의 고장전류분류율이 현행의 기준을 만족함으로써 시스 순환전류 저감장치 보호유닛을 적용한 저감장치의 현장적용 가능성을 제시하였다.

  • PDF

Relocation of Hypocenters occured in and around Kyeongsang basin using by Joint Hypocenter Determination(JHD) method (JHD를 이용한 경상분지 일원에서 발생한 지진의 진원위치 재결정(I))

  • 전정수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.49-56
    • /
    • 1999
  • Crustal velocity model is very important to determine the hypocenters of the local earthquakes because the real crust is more complex and heterogeneous than simple homogeneous layerd model. But the exact crust model in and around Kyeongsang basin area is not fixed till now. To solve this problem Joint Hypocenter Determination(JHD) method is applied to the 133 local earthquakes that is recorded at KIGAM local network from Dec. 14 1994. to May 14, 1998. According to the comparision of earthquake locations and depths for the conventional procedure and JHD relocation procedure each locations is very similar but depth distributions are different. An initial depth distribution derived from the conventional methods is irregular and does not show the general trends. JHD relocations reduce scatter and define a dipping plane which is parallel to and apart 15km north from Ulsan fault.

  • PDF

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF

A Review Study on Devolution of Central Government's Affairs to Local Governments for Occupational Safety and Health Administration in the Lee Myungbak's Government (이명박 정부에서의 산업안전보건 국가사무의 지방이양 추진에 관한 경과 및 문제점 고찰)

  • Park, Doo Yong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.144-150
    • /
    • 2013
  • The devolution of central government's affairs to local governments for several occupational safety and health(OHS) administration affairs was tried by Lee Myungbak's government in 2010. It seems that the trial was eventually failed since only trivial 3 items among 25 trials were made for the devolution. It was found that there was a procedural fault since stake-holders and experts were excluded during preparing the plan. Therefore validity and problems were not properly reviewed. It was also found that the devolution of the OHS administration affairs from the central government to local governments has several disadvantages such as high possibility of deregulation. The devolution of the OHS affairs to local governments is contradictory to uniform principle of safety standards and principle of coincidence of empowerment and responsibility. Therefore it is concluded that the devolution of the OHS affairs to local governments is inappropriate.

The Functions and Characteristics of Distribution Automation System Components (국산 배전자동화시스템 구성설비의 보유기능 및 특성)

  • Ha, B.N.;Park, S.M.;Jang, J.T.;Choi, T.I.;Kim, H.Y.;Oh, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

Transport of SVS from Sudagu to Yangju and Study about harmonic wave, feature of control (서대구S/S SVC의 양주S/S 이설관련 고조파 및 제어특성 검토)

  • Jang, Suk-Han;Shin, Soon-Young;Choi, Man-Sik;Youn, Jong-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.633-635
    • /
    • 2007
  • To cope with increasing power demand in metropolitan area, the power system in Korea has equipped with unit generator of large capacity, high density and uneven distribution, and transmission line of long distance, large capacity and high voltage. As the power system growing up enormous, it has become difficult to maintain the standard voltage in case of radical fluctuation of load or severe change of voltage by power system fault for its weakness of responsive characteristics although the power condenser has been installed to solve the unstability by lack of reactive power. Consequently, we review harmonic wave production and control characteristics to solve unstability problem of voltage in northern metropolitan, to reduce transmission restriction cost and to minimize load shedding by relocation of SVC (Static Var Compensator), which is highly effective for improvement of responsive characteristics for radical voltage fluctuation.

  • PDF

Study on the Fault Current Division Factor in Multi-grounded Distribution System (배전선로 1선 지락고장시 고장전류의 대지유입률 검토)

  • Kang, Moon-Ho;Lim, Yong-Hun;Choi, Jong-Gi;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.671-672
    • /
    • 2007
  • 국내 배전선로는 다중으로 중성선을 접지하여 운영하고 있어 지락고장이 발생하면 큰 고장전류가 발생하며, 이는 중성선 및 가공 지선과 접지극으로 분류되어 전원측으로 귀로한다. 유도전력기술기준에서는 이 분류율을 배전선로의 경우 50%로 규정하고 있어 배전선로 신 증설시 통신선과의 이격거리 확보에 어려움이 발생하고 있다. 따라서 본 논문에서는 국내 배전선로의 1선 지락전류의 분류율을 기술적으로 검토하기 위해 배전선로 설계기준을 바탕으로 1선 지락고장전류의 대지유입률을 모의하고 그 결과를 분석하였다.

  • PDF

Potential Distribution near Street Linght according to the Grounding Electrode (접지극 형상에 따른 가로등 주변의 전위분포)

  • Lee, Bok-Hee;Beak, Young-Hwan;Jeong, Dong-Cheol;Ahn, Chang-Hwan;Shim, Pan-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1453-1454
    • /
    • 2007
  • A street light is an electrical equipment to improve the traffic safety and the security for people in night. However, many accidents due to electric shock have happened in recent, people were interested in the safety of electrical facilities. And people want to know the danger by touch and step voltages. When the electric power lines fall down on the ground, the fault current flows to ground rod and the potential near the ground rod is increased to induce the high touch and step voltages. In this paper, we installed different ground rods with a street light and investigated the electrical potential according to ground methods and the types of ground rod. Finally, we examined the electrical facilities with the experimental result and present the improved technical data for the safety from electric shock

  • PDF

Properties & Performance Evaluation of Disconnector for Surge Arrester (피뢰기용 단로기의 특성 및 성능 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Jeong, Nak-Heon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.546-547
    • /
    • 2005
  • This study aims to evaluate the properties and the performance of the newly designed disconnector for surge arrester. This disconnector was verified with the performance in long-duration current impulse test and high current impulse test. And time-current characteristic test was done at 20A, 200A and 800A(3points) for simulating the internal fault condition of the arrester. The results of this test was very good. Consequently, the newly designed disconnector was, evaluated that it is possible to be used for surge arrester in distribution line system.

  • PDF