• Title/Summary/Keyword: Direct Connection

Search Result 425, Processing Time 0.027 seconds

Operating Chracteristic of Power Converter for Photovoltatic System using Instantaneous Controller (순시치 제어기를 이용한 태양광발전용 전력변환장치 동작특성)

  • 유권종;김홍성;송진수;정영석;강기환;이병구;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.57-65
    • /
    • 1999
  • This paper deals with stand-alone photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell and battery. Therefore SPVS with charge and discharge controller which can operate solar cell at maximum power point is suggested and designed with instantaneous controller. And system operating characteristics are verifieded by experiment with a laboratory prototype in this paper.

  • PDF

Development and fabrication of multi-filamentary Bi(2223)/Ag jointed tape (Bi(2223)/Ag 다심 초전도 접합선재의 제조)

  • 김규태;김정호;김호진;이동욱;주진호;나완수
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.172-175
    • /
    • 2003
  • Critical current ratio and n-value of Bi(2223)/Ag superconducting joint tape were measured as a function of uniaxial pressure. In the superconducting joint method, MM and MSM joint were used ; MM joint is direct connection of two -multi filamentary tapes, and MSM is connection of them by using a single -filamentary tape. It was observed that the critical current ratio(CCR) for jointed tapes was not dependent on the uniaxial pressure but joining methods. The n-value of jointed tapes has similar trends with that of the CCR. Especially, double MSM joint showed the highest electrical properties as 63.4-76.0%(CCR) and 3.5-5.1 (n-value). It is considered that the improvements are due to the better inter connections of multifilaments by two single filamentary tapes on both sides.

  • PDF

A Study on Networks Applications improved Mobile P2P (개선된 모바일 P2P 네트워크 구현에 관한 연구)

  • Kim Yong-Hun;Park Jong-Min;Cho Beom-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1458-1464
    • /
    • 2005
  • A P2P is a method that can share and exchange on digital resources through a direct connection on personnel without a central server. In this paper, Although the P2P application that uses our proposed framework should obtain one or more IP addresses of the neighbor peers manually, after instantiate, the application can do its job while maintaining connection to the network continuously and automatically. To evaluate our proposed scheme, we measured and analyzed the time for a peer to reconnect to the network when the mediating peer fails and the network isolation occurs.

Analysis of Overvoltage and Reduction Methods of Insulation Joint Box in Underground Power Cable Systems (지중송전케이블계통에서 절연통의 과전압 해석 및 억제대책 검토)

  • Hong, Dong-Seok;Jeong, Chae-Gyun;Lee, Jong-Beom;Seo, Jae-Ho;Jo, Han-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.102-108
    • /
    • 2002
  • This paper describes the overvoltage analysis and reduction methods of insulation joint boxes in underground transmission power cables when direct lightning surge strikes to overhead transmission line. An actual 154kV combined transmission line with underground Power cables was modelled in ATPDraw for simulation. Simulations were performed to analyze the overvoltage between insulation joint boxes, sheath-to-ground voltage according to the distance between cable conductors, cable lengths, burying types, CCPU connection types. The most effective method to reduce the induced overvoltage of Insulation joint boxes was proposed. It is evaluated that the proposed reduction method riven from the detailed simulations can be effectively applied to the actual underground power cable systems.

Using integrated displacement method to time-history analysis of steel frames with nonlinear flexible connections

  • Hadianfard, M.A.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.5
    • /
    • pp.675-689
    • /
    • 2012
  • Most connections of steel structures exhibit flexible behaviour under cyclic loading. The flexible connections can be assumed as nonlinear rotational springs attached to the ends of each beam. The nonlinear behaviour of the connections can be considered by suitable moment-rotation relationship. Time-history analysis by direct integration method can be used as a powerful technique to determine the nonlinear dynamic response of the structure. In conventional numerical integration, the response is evaluated for a series of short time increments. The limitations on the size of time intervals can be removed by using Chen and Robinson improved time history analysis method, in which the integrated displacements are used as the new variables in integrated equation of motion. The proposed method permits longer time intervals and reduces the computational works. In this paper the nonlinearity behaviour of the structure is summarized on the connections, and the step by step improved time-history analysis is used to calculate the dynamic response of the structure. Several numerical calculations which indicate the applicability and advantages of the proposed methodology are presented. These calculations illustrate the importance of the effect of the nonlinear behaviour of the flexible connections in the calculation of the dynamic response of steel frames.

Analysis of Flow and Congestion control in USN (USN의 전송 계층 프로토콜에서 에러 및 흐름제어의 성능 평가)

  • Cha, Hyun-Soo;Kang, Chul-Kun;Yoo, Seung-Wha;Kim, Ki-Hyung
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.45-50
    • /
    • 2008
  • Many applications of sensor network require connection to the Internet. The transmission protocol of traditional sensor network was designed within the sensor network itself. However, based on 6LoWPAN which can be accessed using IPv6, direct connection is possible between the sensor network and the TCP/IP network outside. Transmission of data in applications of sensor network falls into two main categories. One is a small packet that is periodically produced such as packet related to temperature and humidity. The other is a relatively large packet that brings about network overheads such as images. We investigated the conformance test and pros and cons of application data over the transmission protocol of Zigbee and 6LoWPAN. As a result, both Zigbee and 6LoWPAN have shown low rate of loss for periodic data and have in creased reliability of data transfer. When transmitting streaming image data, both ACK, non ACK mode of Zigbee and UDP of 6LoWPAN minimized transmission time but suffered the consequences of high packet loss. Even though TCP of 6LoWPAN required a long transmission time, we were able to confirm that no loss has occurred.

  • PDF

A Study on Traffic analysis for System Optimization of CDMA base station and repeaters (CDMA 기지국과 중계기의 시스템 최적화를 위한 Traffic 분석 기법)

  • Jo, Ung;Chin, Yong-Ohk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4C
    • /
    • pp.333-341
    • /
    • 2002
  • This article is written to make a foundation for effective radio network engineering by enabling the accurate traffic assumption between Base Station (BTS : Base Station Transceiver Subsystem) md Repeater through the scientific and systematic analysis of mobile traffic dealt within CDMA Base Station. Among these, Repeater, having direct physical connection with BTS, simply does the remote relay function but the volume of the traffic flowed into the repeater is not accountable. The total BTS traffic is the sum of traffic dealt by the BTS and multiple Repeaters. In this article, we tried traffic analysis of this kind by adopting RTD (Round Trip Delay) which is specially designed to measure distribution of the distance between the Base Station and the Mobile station by differentiating the traffic dealt by BTS from traffic dealt by Repeaters. The fact that the connection between mobile station and BTS via Repeater (which is located remotely) yields far more delay than the direct connection between mobile station and BTS is the clue of this article. Based on this fact, Time Delay equipment was put at the receiving side of the Repeater to add certain amount of delay to the traffic to BTS and the result showed that the 99.78% of the traffic can be identified.

The Evaluation of Connectivity between Natural Environment (Forests and Rivers) and Neighborhood Parks Inside Cities in Gyeonggi-do (도시 내 자연환경(산림, 하천)과 근린공원의 연결 현황 평가 및 연결방안)

  • Sung, Hyun-Chan;Kim, Su-Ryeon;Kang, Da-In;Hwang, So-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.5
    • /
    • pp.49-59
    • /
    • 2015
  • In this research, the connectivity status between natural environment (forests and rivers) and urban parks in view of ecological networks in a city is evaluated and on the basis of these evaluation results, a future connectivity enhancing recommendations are suggested. As a result, the 96.8% of the connectivity role of the neighborhood parks were core or connected parks and as in terms of the ecological pattern on the outer park, 84.1% of the case neighborhood parks were connected to the ecological element at least one side. Therefore, it can be expected to play a role as corridor that enables the direct connection with the natural environment if the connection plan is well established. As a result of connectivity evaluation of the parks, inside of the parks had low ecological element overall and had low connectivity, outside of the parks had 1.5 times more of low connectivity parks than high connectivity parks, and had similar disconnections such as facilities(fence, soundproof walls, breast walls, etc.), developments(roads, apartment complexes, industrial complexes, etc.), or poor greens regardless of the neighborhood with the ecological elements. To increase the connectivity of ecological network, the cities already built shall secure primarily green territory where can connect with the isolated park due to the surrounding with the developing areas and when planning for new cities or residential complexes, it shall establish a connection plan with the nearby at the beginning.

Characteristics of Food Waste Leachate Treatment in Thermophilic two Stage Anaerobic Digestion Combined UF Membrane (막결합형 고온 이상 혐기성 소화공정에서 음폐수 처리 특성)

  • Kim, Young-O;Jun, Duk-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.21-24
    • /
    • 2012
  • In this study, Anaerobic Membrane Bioreactor(AnMBR) treating food waste leachate was operated to investigate treatment efficiency of anaerobic process, operational parameters and production of biogas. AnMBR was operated under the condition of filtration type of inside-out mode. AnMBR was operated under the condition that range of permeate flux was from 15 to 20 LMH and range of transmembrane pressure was from 1 to $3 kgf/cm^2$. It was not good that AnMBR was performed under direct connection between anaerobic reactor and external UF module. so, this connection method changed to indirect connection using buffer tank was placed between anaerobic reactor and UF external module. TCOD and SCOD values were that influent were about 113 g/L, 62 g/L and effluent were 25 g/L, 12 g/L, respectively. also TCOD and SCOD removal efficiency were 77% and 81%, respectively. but after added UF process, COD and SCOD removal efficiency was increased to 93% and 86%, respectively.

A study on chemical bonding characteristics of the interface between curved FRP panels for consecutive structural assembly (곡면 FRP 패널 부재 연속시공을 위한 연결부 화학적 접합 특성에 관한 연구)

  • Lee, Gyu-Phil;Shin, Hyu-Soung;Jung, Woo-Tai
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.79-91
    • /
    • 2012
  • A curved fiber reinforced polymer (FRP) panel is produced with a certain width depending on allowances of manufacturing processes and facilities. An targeted arch-shaped structure could be built by sequential connection of series of the FRP panels. The connection manner between the FRP panels could be given by chemical treatment, mechanical treatment and hybrid method. Among those, the connection between the panels by chemical treatment is commonly adopted. Therefore, For an optimized design of the connected part between FRP pannels, a number of direct shear tests have been undertaken in terms of a number of parameters: surface treatment conditions, bonding materials, etc.. As results, surface grinding condition by sand paper or surface treatment by sand blasting appear properly acceptable methods, and epoxy and acryl resins are shown to be effective bonding materials for the purpose in this study.