• Title/Summary/Keyword: Detection Key

Search Result 1,206, Processing Time 0.026 seconds

Design and Implementation of $160\times192$ pixel array capacitive type fingerprint sensor

  • Nam Jin-Moon;Jung Seung-Min;Lee Moon-Key
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.82-85
    • /
    • 2004
  • This paper proposes an advanced circuit for the capacitive type fingerprint sensor signal processing and an effective isolation structure for minimizing an electrostatic discharge(ESD) influence and for removing a signal coupling noise of each sensor pixel. The proposed detection circuit increases the voltage difference between a ridge and valley about $80\%$ more than old circuit. The test chip is composed of $160\;\times\;192$ array sensing cells $(9,913\times11,666\;um^2).$ The sensor plate area is $58\;\times\;58\;um^2$ and the pitch is 60um. The image resolution is 423 dpi. The chip was fabricated on a 0.35um standard CMOS process. It successfully captured a high-quality fingerprint image and performed the registration and identification processing. The sensing and authentication time is 1 sec(.) with the average power consumption of 10 mW at 3.0V. The reveal ESD tolerance is obtained at the value of 4.5 kV.

  • PDF

Direct Determination of Uric Acid in Human Serum Samples Using Polypyrrole Nanoelectrode Ensembles

  • Yang, Guangming;Tan, Lin;Shi, Ya;Wang, Suiping;Lu, Xuxiao;Bai, Huiping;Yang, Yunhui
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.454-458
    • /
    • 2009
  • Polypyrrole (PPy) nanotubes have been synthesized by chemical oxidative polymerization of pyrrole within the pores of polycarbonate membrane using the technology of diffusion of solutes. The nanotubes array prepared by the proposed method can be considered as nanoelectrode ensembles (NEEs). An amperometric uric acid sensor based on PPy NEEs has been developed and used for determination of uric acid in human serum samples. The electrode can direct response to uric acid at potential of 0.60V vs. SCE with wide linear range of $1.52{\times}10^{-6}\;to\;1.54{\times}10^{-3}\;M.\;The\;detection\;limit\;is \;3.02{\times}10^{-7}$ M. This sensor has been used to determine uric acid in real serum samples. PPy NEEs is thought of as a good application in the foreground.

Specified Object Tracking in an Environment of Multiple Moving Objects using Particle Filter (파티클 필터를 이용한 다중 객체의 움직임 환경에서 특정 객체의 움직임 추적)

  • Kim, Hyung-Bok;Ko, Kwang-Eun;Kang, Jin-Shig;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.1
    • /
    • pp.106-111
    • /
    • 2011
  • Video-based detection and tracking of moving objects has been widely used in real-time monitoring systems and a videoconferencing. Also, because object motion tracking can be expanded to Human-computer interface and Human-robot interface, Moving object tracking technology is one of the important key technologies. If we can track a specified object in an environment of multiple moving objects, then there will be a variety of applications. In this paper, we introduce a specified object motion tracking using particle filter. The results of experiments show that particle filter can achieve good performance in single object motion tracking and a specified object motion tracking in an environment of multiple moving objects.

A Study on Design and Fabrication of SRD Impulse Generator and Antenna for Ground Penetrating Radar System (지반투과 레이더 시스템을 위한 SRD 임펄스 발생기 및 안테나의 설계 및 제작에 관한 연구)

  • Kim, Hyoung-Jong;Shin, Suk-Woo;Choi, Gil-Wong;Choi, Jin-Joo;Shin, Shang-Youal
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.509-516
    • /
    • 2011
  • In this paper, a ground penetrating radar(GPR) system is implemented for landmine detection. The performance of the GPR system is associated with the characteristics of local soil and buried target. The choice of the center frequency and the bandwidth of the GPR system are the key factors in the GPR system design. To detect a small and shallow target, the higher frequencies are needed for high depth resolution. We have been designed, fabricated and tested a new impulse generator using step recovery diodes. The measured impulse response has an amplitude of 6.2V and a pulse width of 250ps. The implemented GPR system has been tested real environmental conditions and has proved its ability to detect a small buried target.

Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor (펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구)

  • Choi, Woo-Jin;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

A Study on the RAMS Analysis of Urban Maglev Train Control System (도시형자기부상열차 열차제어시스템 RAMS 분석에 관한 연구)

  • Yun, Hak-Sun;Lee, Key-Seo;Ryou, Sung-Kyun;Yang, Dong-In
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.515-525
    • /
    • 2011
  • In this study, Urban maglev is applied to inductive-loop speed and position detection system for the top-level classification system for the entire system, and performed functional analysis On-board signal equipment, Wayside-signal equipment divided by the reliability, availability, maintainability, and safety through analysis of the proposed formula. RDB and by applying a system service for each device was calculated to availability, safety analysis. The PHA, FMEA, HAZOP over the Top Event of the FTA is performed by presenting the results. This also shows approach methods and relative activities for project to accomplish and ensure the system requirements.

3D Environment Perception using Stereo Infrared Light Sources and a Camera (스테레오 적외선 조명 및 단일카메라를 이용한 3차원 환경인지)

  • Lee, Soo-Yong;Song, Jae-Bok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.5
    • /
    • pp.519-524
    • /
    • 2009
  • This paper describes a new sensor system for 3D environment perception using stereo structured infrared light sources and a camera. Environment and obstacle sensing is the key issue for mobile robot localization and navigation. Laser scanners and infrared scanners cover $180^{\circ}$ and are accurate but too expensive. Those sensors use rotating light beams so that the range measurements are constrained on a plane. 3D measurements are much more useful in many ways for obstacle detection, map building and localization. Stereo vision is very common way of getting the depth information of 3D environment. However, it requires that the correspondence should be clearly identified and it also heavily depends on the light condition of the environment. Instead of using stereo camera, monocular camera and two projected infrared light sources are used in order to reduce the effects of the ambient light while getting 3D depth map. Modeling of the projected light pattern enabled precise estimation of the range. Two successive captures of the image with left and right infrared light projection provide several benefits, which include wider area of depth measurement, higher spatial resolution and the visibility perception.

Detection of Flip-chip Bonding Error Through Edge Size Extraction of X-ray Image (X선 영상의 에지 추출을 통한 플립칩 솔더범프의 접합 형상 오차 검출)

  • Song, Chun-Sam;Cho, Sung-Man;Kim, Joon-Hyun;Kim, Joo-Hyun;Kim, Min-young;Kim, Jong-Hyeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.9
    • /
    • pp.916-921
    • /
    • 2009
  • The technology to inspect and measure an inner structure of micro parts has become an important tool in the semi-conductor industrial field with the development of automation and precision manufacturing. Especially, the inspection skill on the inside of highly integrated electronic device becomes a key role in detecting defects of a completely assembled product. X-ray inspection technology has been focused as a main method to inspect the inside structure. However, there has been insufficient research done on the customized inspection technology for the flip-chip assembly due to the interior connecting part of flip chip which connects the die and PCB electrically through balls positioned on the die. In this study, therefore, it is implemented to detect shape error of flip chip bonding without damaging chips using an x-ray inspection system. At this time, it is able to monitor the solder bump shape by introducing an edge-extracting algorithm (exponential approximation function) according to the attenuating characteristic and detect shape error compared with CAD data. Additionally, the bonding error of solder bumps is automatically detectable by acquiring numerical size information at the extracted solder bump edges.

Scrubbing Scheme for Advanced Computer Memories for Multibit Soft Errors (다중 비트 소프트 에러 대응 메모리 소자를 위한 스크러빙 방안)

  • Ryu, Sang-Moon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.701-704
    • /
    • 2011
  • The reliability of a computer system largely depends on that of its memory systems, which are vulnerable to soft errors. Soft errors can be coped with a combination of an Error Detection & Correction circuit and scrubbing operation. Smaller geometries and lower voltage of advanced memories makes them more prone to suffer multibit soft errors. A memory structure against multibit soft errors and a suitable scrubbing scheme for it were proposed. This paper introduces a key issue for the scrubbing of the memories with protection against multibit soft errors and the result of the performance analysis from a reliability point of view.

  • PDF

Passive Ranging Based on Planar Homography in a Monocular Vision System

  • Wu, Xin-mei;Guan, Fang-li;Xu, Ai-jun
    • Journal of Information Processing Systems
    • /
    • v.16 no.1
    • /
    • pp.155-170
    • /
    • 2020
  • Passive ranging is a critical part of machine vision measurement. Most of passive ranging methods based on machine vision use binocular technology which need strict hardware conditions and lack of universality. To measure the distance of an object placed on horizontal plane, we present a passive ranging method based on monocular vision system by smartphone. Experimental results show that given the same abscissas, the ordinatesis of the image points linearly related to their actual imaging angles. According to this principle, we first establish a depth extraction model by assuming a linear function and substituting the actual imaging angles and ordinates of the special conjugate points into the linear function. The vertical distance of the target object to the optical axis is then calculated according to imaging principle of camera, and the passive ranging can be derived by depth and vertical distance to the optical axis of target object. Experimental results show that ranging by this method has a higher accuracy compare with others based on binocular vision system. The mean relative error of the depth measurement is 0.937% when the distance is within 3 m. When it is 3-10 m, the mean relative error is 1.71%. Compared with other methods based on monocular vision system, the method does not need to calibrate before ranging and avoids the error caused by data fitting.