• 제목/요약/키워드: Department of Optometry

검색결과 307건 처리시간 0.029초

한국인 20세부터 24세까지 각막 두께와 안압의 분석 (Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea)

  • 김덕훈
    • 한국임상보건과학회지
    • /
    • 제11권1호
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

스피넬 페라이트의 비이완 표면에너지 계산 (Calculating of the Unrelaxed Surface Energy of Spinel Ferrites)

  • 신형섭;손정호
    • 한국재료학회지
    • /
    • 제25권12호
    • /
    • pp.713-718
    • /
    • 2015
  • A new method is proposed for the calculation of the unrelaxed surface energy of spinel ferrite. The surface energy calculation consists of (1) setting the central and computational domains in the semi-infinite real lattice, having a specific surface, and having an infinite real lattice; (2) calculation of the lattice energies produced by the associated portion of each ion in the relative domain; and (3) dividing the difference between the semi-infinite lattice energy and the infinite lattice energy on the exposed surface area in the central domain. The surface energy was found to converge with a slight expansion of the domain in the real lattice. This method is superior to any other so far reported due to its simple concept and reduced computing burden. The unrelaxed surface energies of the (100), (110), and (111) of $ZnFe_2O_4$ and $Fe_3O_4$ were evaluated by using in the semi-infinite real lattices containing only one surface. For the normal spinel $ZnFe_2O_4$, the(100), which consisted of tetrahedral coordinated $Zn^{2+}$ was electrostatically the most stable surface. But, for the inverses pinel $Fe_3O_4$, the(111), which consisted of tetrahedral coordinated $Fe^{3+}$ and octahedral coordinated $Fe^{2+}$ was electrostatically the most stable surface.

Analysis on the corneal thickness and anterior chamber depth of the Keratoconus using Pentacam

  • Kim, Douk-Hoon;Sapkota, Kishor
    • 한국임상보건과학회지
    • /
    • 제6권1호
    • /
    • pp.1089-1096
    • /
    • 2018
  • Purpose: To investigate the corneal thickness and anterior chamber depth (ACD) of eyes with Keratoconus in the Korean population with the Pentacam. Methods: The subjects consisted of 84 eyes from Keratoconic adults aged 7-59 years during 2010. The thinnest area, apex zone, and pupil centre of the corneal thickness were measured using the Pentacam pachymetry. ACD value was also measured with Pentacam. Results: There was a statistically significant relationship between thickness of the cornea at the apex area and the pupil centre (p=0.0001). However, there was no statistical difference (p>0.5) in the mean thickness of thinnest area, apex zone, pupil centre of cornea between right eye and left eye. Also, correlation between ACD and corneal thickness in all subjects had no statistical differences (p>0.05) in all subjects. Conclusion: These results suggested that the regional thickness of cornea and ACD with Pentacam can provide correct and useful diagnostic information of the morphology of Keratoconus for the RGP contact lens and diagnosis of abnormal corneal refraction surgery.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • 한국임상보건과학회지
    • /
    • 제7권1호
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

한국 성인 여성 집단에서 검열과 안구돌출의 상관관계 (Correlation between Palpebral Fissure and Exophthalmos in Korean Adult Women Population)

  • 김덕훈
    • 한국임상보건과학회지
    • /
    • 제2권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose. This study was to investigate the relationship between the palpebral fissure size and the exophthalmos in a population of Korean adult women subjects with normal eye status. Methods. From November 2012 to September 2013, The authors analyzed the morphological values in 73 Korean adults population. The test was performed using the Hertel exophthalmometer and verner califer. Analysis of subjects data were recorded using the spss version 20.0 a statistical program (IBM Co, Armonk, NY USA). Results. The average age of the 73 subjects (146 eyes) was (21.219+/-0.261)mm. the average value of palpebral fissure was (25.110+/-1.646)mm in width and (8.096+/-1.464)mm in height. The average value of exophthalmos was (15.002+/-1.922)mm. There was a significant relationship(P>0.05) in the average size between the width and height in palpebral fissure. Also, there was a significant relationship(P>0.05) in the average size between the palpebral fissure width and exophthalmos. On the other hand, there was a significant relationship(P>0.01) in the average size of palpebral fissure height and exophthalmos. Conclusions: In this study, these results suggested that the palpebral fissure and exophthalmos had a significant relationship in the average value of size in Korean adult women population.

대구 달서구 지역 초등학생들의 근시진행 정도에 대한 연구 (A Study of Myopia Progression Status for a Elementary School Student Group in Daegu Dalseogu Region)

  • 이병화
    • 한국임상보건과학회지
    • /
    • 제1권3호
    • /
    • pp.33-37
    • /
    • 2013
  • Purpose. In this study, we divided elementary school students into two investigated groups. The A group is the lower graders(boys 9, girls 18), and the B group is the higher graders(boys 10, girls 13). The myopia progression has been compared with to each group and it has been investigated for variable terms. Methods. We have analyzed the refraction inspection record of 50 students(boys 19, girls 31) who visited optical shops and more than two times in one year. Results. The subject of study were 50 students(boys 19, girls 31). 1. The distribution of spherical equivalent power with ages : boys A group -2.42D, girls A group -2.53D, boys B group -2.63D, girls B group -2.78D. boys B group -2.63D, girls B group -2.78D. 2. The monthly variation of spherical equivalent power : -0.055D(A), -0.04D(B) in boys, and -0.065D(A), -0.07D(B) in girls. Conclusions. Considering monthly variations and Supposing that the time of changing spectacles degrees were the time of refracting inspection. The result : 3.8 month for A group, 4.5 month for B group in boys, and 3.5 month for A group, 5.2 month for B group in girls.

  • PDF

Caffeic Acid Phenethyl Ester Inhibits Cell Proliferation and Induces Apoptosis in Human Ovarian Cancer Cells

  • Park, Hyung-Joo;Yang, Seung-Joo;Mo, Jin-Young;Ryu, Geun-Chang;Lee, Kyung-Jin
    • 환경생물
    • /
    • 제28권4호
    • /
    • pp.196-201
    • /
    • 2010
  • The phenethyl ester of caffeic acid (CAPE), an active component of honeybee propolis extract, is shown to inhibit cancer growth previously. However, studies on human ovarian cancer are largely obscure. This study evaluated the effects of CAPE as a potential anti-proliferative and pro-apoptotic agent in the human ovarian cancer line, OVCAR-3. CAPE treated OVCAR-3 cells showed inhibition of cell viability and proliferation in a dose-dependent manner by WST-1 assay, LDH assay and bromodeoxyuridine (BrdU) incorporation assay. Furthermore, CAPE-mediated OVCAR-3 cell growth inhibition was associated with apoptotic changes as evident by cell cycle arrest and accumulation of cells in the apoptotic phase and DNA fragmentation. Taken together, CAPE inhibits cell proliferation via DNA synthesis reduction and induces apoptotic cell death via DNA damage, thus elucidating a novel, plausible mechanism of CAPE anti-tumorigenic property in OVCAR-3 cells.

광학적 모니터링 장비를 이용한 안경렌즈의 무반사 코팅 (Anti-reflection Coating using Optical Monitoring System)

  • 정부영
    • 한국안광학회지
    • /
    • 제16권2호
    • /
    • pp.159-165
    • /
    • 2011
  • 목적: 광학적 모니터링 장비를 이용한 안경렌즈의 무반사 코팅의 신뢰성과 재현성을 연구하였다. 방법: 광학적 모니터링 장비를 이용한 무반사 코팅의 수행 가능성을 확인하기 위해서 Essential Macleod 프로그램을 이용하여 RunSheet 실행과 랜덤 에러 전산시늉을 실시하였다. 전산 시늉 후에 AR coating의 재현성 확인을 위해서 19 배치의 코팅 프로세스를 실시하였다. 결과: 19 배치의 코팅 프로세스 반사율 결과는 약 0.5%의 에러 내에서의 좋은 재현성을 보였다. 결론: 결과들로부터 우리는 광학적 모니터링 법을 이용한 무반사 코팅의 가능성과 우수한 재현성을 확인하였다.

적극적 스트레스 대처매개 중재가 임상실습 스트레스와 만족도에 미치는 영향 (Effects of Aggressive Stress Response Mediation on Clinical Practice Stress and Satisfaction)

  • 이정윤;황혜경
    • 한국임상보건과학회지
    • /
    • 제7권2호
    • /
    • pp.1345-1354
    • /
    • 2019
  • Purpose: This study aimed to determine the mediating effects of aggressive stress response on the association between clinical practice stress and clinical practice satisfaction in ophthalmic optics majors and provide basic data that could help form opticians' professionalism and make clinical practice more effective. Methods: This study was conducted in 236 sophomores and juniors in Daegu and North Gyeongsang Province who had finished clinical practice. Hierarchical regression analysis and mediating effect testing were performed to determine the associations among clinical practice stress, clinical practice satisfaction, and aggressive stress response and determine the mediating effects of aggressive stress response on the association between clinical practice stress and clinical practice satisfaction. Results: Clinical practice stress was significantly negatively correlated with clinical practice satisfaction and aggressive stress response (p<0.01), and aggressive stress response was significantly positively correlated with clinical practice satisfaction (p<0.01). The association between clinical practice stress and clinical practice satisfaction was more likely to be explained by the addition of clinical practice stress than by being aggressive stress response controlled, which statistically significantly met the criteria for mediating effects (p<0.001). Conclusions: It is necessary to pay more attention to program development and teaching methods within the department of ophthalmic optics so that ophthalmic optics majors can utilize aggressive stress response to overcome clinical practice stress effectively and improve clinical practice satisfaction.

각막지형도(topography) 각막곡률로부터 토릭 각막형상의 수식화 (Mathematical Expression of the Toric Cornea using Corneal Topography Measurements)

  • 김대수
    • 한국안광학회지
    • /
    • 제16권4호
    • /
    • pp.439-444
    • /
    • 2011
  • 목적: 수평축과 수직축 비가 다른 토릭각막의 형상을 수학적인 함수로 표현하여 각막곡률 분포의 분석과 콘택트 렌즈 착용에 필요한 눈물두께 계산에 적용한다. 방법: 각막을 타원함수로 가정하고 함수로부터 유도된 곡률반경식과 각막 토포그라피 측정 곡률반경을 일치시켜 타원함수의 변수를 결정하였다. 계산은 작성한 엑셀프로그램을 사용하였다. 결과: 중심이 각막 정점에 위치하지 않는 리본(나비)형 토포그라피 이미지를 가지는 직난시 각막의 수평, 수직 각 축에 대해 각막의 형상을 수치적으로 알 수 있는 타원함수를 구하였다. 결론: 각막에 대해 고도의 수차 등이 요구되지 않는 응용, 예를 들면 콘택트렌즈 피팅, 난시교정 등에 각막 형상을 단순한 타원함수로 표현하는 것이 편리할 것으로 판단된다.