• 제목/요약/키워드: Dental Engineering

검색결과 1,045건 처리시간 0.028초

치기공과 학생의 취업스트레스와 진로결정 자기효능감의 연관성 (A Study on the Relationship Between Job Seeking Stress and career decision-making self-efficacy in students of Department of Dental Technology)

  • 강월;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.247-256
    • /
    • 2016
  • Purpose: This study is to analyse the job seeking stress, to see the relationship Between Job Seeking Stress and career decision-making self-efficacy in students of department of dental technology. Method: For this, the students of department of dental technology in daegu and daejeon and wonkwang university selected at May 2016. A question investigation was used in a entry method of self-estimation. Furthermore a total of 151 person was used as final analysis data. Statical analysis was performed with SPSS 22.0. An analysis of frequency, two sample t-test, one-way ANOVA, Multiple regression was used. Results: Firstly, personal expenses affected beneficially statistically the Job Seeking Stress(p<.05). Secondly, sex, Score, Major satisfaction, personal expenses affected beneficially statistically the career decision-making self-efficacy(p<.05). Thirdly, University environment and academic stress in the Job Seeking Stress affected beneficially statistically the career decision-making self-efficacy(choice target). Conclusion: The study found out that there was significant effect when increased to university environment and academic stress in Job Seeking Stress, the career decision-making self-efficacy was decreased. So the study proved that when helping students facing difficulties due to the career decision-making self-efficacy, it is important to decreased their university environment and academic stress.

In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium

  • Suzuki, Ginga;Shimizu, Satoshi;Torii, Mana;Tokue, Ai;Ying, Guo;Yoshinari, Masao;Hoshi, Noriyuki;Kimoto, Katsuhiko;Miura, Hiromi;Hayakawa, Tohru;Ohkubo, Chikahiro
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.369-375
    • /
    • 2020
  • PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDF-Ti were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.

치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가 (Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece)

  • 한명철;김정관;최명욱
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

The effect of powder A2/powder A3 mixing ratio on color and translucency parameters of dental porcelain

  • Lee, Wan-Sun;Kim, So-Yeon;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.400-405
    • /
    • 2015
  • PURPOSE. The purpose of this study is to mix dental ceramic powder in varying ratios and evaluate the effect of the mixing ratio on color and translucency. MATERIALS AND METHODS. The ceramic powder of shade A3 of the same product was mixed with the shade A2 of three products: IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein), Vintage Halo (SHOFU Inc., Kyoto, Japan), and Ceramco 3 (Ceramco-Dentsply, Burlington, NJ, USA) in the following fixed ratios (0 wt%, 25 wt%, 50 wt%, 75 wt%, and 100 wt%) and then fired. A total of 150 specimen of ceramic fired were manufactured in a regular size (W: 8.5 mm, L: 10.5 mm, and H: 1.5 mm). For color and translucency, $L^*$, $a^*$, and $b^*$ were measured and Two-way analysis of variance (ANOVA) and One-way analysis of variance (ANOVA) were used for data analysis (${\alpha}$=0.05). RESULTS. The higher the mixing ratio was, $L^*$, $a^*$, and $b^*$ of IPS e.max Ceram were all increased, and $L^*$ of Vintage Halo was reduced and $a^*$ and $b^*$ were increased. $L^*$ and $a^*$ of Ceramco3 were reduced and $b^*$ of Ceramco3 was increased. Color difference (${\Delta}E^*ab$) was increased in all three products as the mixing ratio got higher. Increased mixing ratios resulted in decreased translucency parameter (TP) values for IPS e.max Ceram but increased TP values for Vintage Halo and Ceramco3. CONCLUSION. In this limited study, CIE $L^*$, $a^*$, and $b^*$ were influenced by the mixing ratio of the A3 powders and porcelain powder mixtures represented a various color and translucency.

쾌속 조형 기술을 이용하여 제작된 3본 고정성 보철물의 적합도 평가 (Marginal fit evaluation of 3 unit fixed dental prostheses fabricated by rapid prototyping method)

  • 김기백;김재홍;김웅철;김혜영;김지환
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.105-111
    • /
    • 2012
  • Purpose: The purpose this study was to evaluate the marginal fitness of metal copings fabricated using rapid prototyping method and to compare the fitness with copings by conventional method. Then clinical availability of fixed dental prostheses (FDPs) fabricated using rapid prototyping method shall be confirmed based on marginal fitness. Methods: Ten same cases of3 unit FDPs epoxy models (abutment teeth 14 and 16) were manufactured. Each of ten epoxy models were scanned by 3shape D-700 scanner to be designed by experienced technician, and photopolymer 3 unit FDPs were fabricated using rapid prototyping methodand fabricated using Lost wax technique (LW) with same models. Marginal fitness of 3 unit FDPs were measured by silicone replica technique. T-test of independent sample for statistical analysis was executed with SPSS 12.0K for Windows. (${\alpha}$=.05) Results: Significantly higher mean (SD) marginal fitness (P<.000) were observed in the RP group $(95.9(18.0){\mu}m$ compared to the conventionally LW group $(80.1(13.8){\mu}m$. Conclusion: Marginal fitness of LW group showed excellent rather than RP group. However marginal fitness of 3 unit FDPs fabricated by RP method did not get out of clinical allowance value range significantly to allow clinical application.

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.

Effects of the sintering conditions of dental zirconia ceramics on the grain size and translucency

  • Kim, Mi-Jin;Ahn, Jin-Soo;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.161-166
    • /
    • 2013
  • PURPOSE. This study aimed to identify the effects of the sintering conditions of dental zirconia on the grain size and translucency. MATERIALS AND METHODS. Ten specimens of each of two commercial brands of zirconia (Lava and KaVo) were made and sintered under five different conditions. Microwave sintering (MS) and conventional sintering (CS) methods were used to fabricate zirconia specimens. The dwelling time was 20 minutes for MS and 20 minutes, 2, 10, and 40 hours for CS. The density and the grain size of the sintered zirconia blocks were measured. Total transmission measurements were taken using a spectrophotometer. Two-way analysis of variance model was used for the analysis and performed at a type-one error rate of 0.05. RESULTS. There was no significant difference in density between brands and sintering conditions. The mean grain size increased according to sintering conditions as follows: MS-20 min, CS-20 min, CS-2 hr, CS-10 hr, and CS-40 hr for both brands. The mean grain size ranged from 347-1,512 nm for Lava and 373-1,481 nm for KaVo. The mean light transmittance values of Lava and KaVo were 28.39-34.48% and 28.09-30.50%, respectively. CONCLUSION. Different sintering conditions resulted in differences in grain size and light transmittance. To obtain more translucent dental zirconia restorations, shorter sintering times should be considered.

치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가 (Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models)

  • 이경탁;김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권3호
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.