Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece

치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가

  • 한명철 (부산대학교 기계공학부) ;
  • 김정관 (부산대학교 기계공학부) ;
  • 최명욱 (부산대학교 대학원 기계공학부)
  • Received : 2008.10.09
  • Accepted : 2010.10.20
  • Published : 2011.01.01

Abstract

The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

Keywords

References

  1. Dyson, J. E. and Darvell, B. W., "The development of the dental high speed air turbine handpiece-part 1," Australian Dental Journal, Vol. 38, No. 1, pp. 49-58, 1993. https://doi.org/10.1111/j.1834-7819.1993.tb05451.x
  2. Dyson, J. E. and Darvell, B. W., "The development of the dental high-speed air turbine handpiece-part 2," Australian Dental Journal, Vol. 38, No. 2, pp. 131-143, 1993. https://doi.org/10.1111/j.1834-7819.1993.tb05475.x
  3. Dyson, J. E. and Darvell, B. W., "Aspect of the design of morden dental air turbine handpieces," Australian Dental Journal, Vol. 38, No. 6, pp. 456-470, 1993. https://doi.org/10.1111/j.1834-7819.1993.tb04761.x
  4. Dyson, J. E. and Darvell, B. W., "Flow and free running speed characterization of dental air turbine handpieces," Journal of Dentistry, Vol. 27, No. 7, pp. 456-477, 1999.
  5. Dyson, J. E. and Darvell, B. W., "Torque, power and efficiency characterization of dental air turbine handpieces," Journal of Dentistry, Vol. 27, No. 8, pp. 573-586, 1999. https://doi.org/10.1016/S0300-5712(99)00038-X
  6. Yoon, G.-S., Lee, Y.-H., Heo, Y.-M., Seo, T.-I. and Choi, G.-U., "Development of Air-powered Handpiece for Surgical Operation," Journal of the Korean Society for Precision Engineering, Vol. 21, No. 3, pp. 188-193, 2004.
  7. Noh, J.-G., Jeong, E.-H., Lee, E.-S. and Kim, J. "Numerical Flow Analysis of Partial Admission Turbine Using a Frozen Rotor Method," Journal of Korean Flow Machinery, Vol. 7, No. 6, pp. 15-20, 2004. https://doi.org/10.5293/KFMA.2004.7.6.015
  8. International Standard 7785-1, "Dental handpiece part 1: high-speed air-turbine handpiece," International Standard Organization, 1992.
  9. Leonard, D. L. and Charlton, D. G., "Performance of High-speed Dental Handpiece Subjected to Simulated Clinical Use and Sterilization," J. Am. Dent. Assoc., Vol. 130, No. 9, pp. 1301-1311, 1999. https://doi.org/10.14219/jada.archive.1999.0400