• Title/Summary/Keyword: Decoupling design

Search Result 174, Processing Time 0.023 seconds

A Study on Optimal Design of Capacitance for Active Power Decoupling Circuits (능동 전력 디커플링 회로의 커패시턴스 최적 설계에 관한 연구)

  • Baek, Ki-Ho;Park, Sung-Min;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.181-190
    • /
    • 2019
  • Active power decoupling circuits have emerged to eliminate the inherent second-order ripple power in a single-phase power conversion system. This study proposes a design method to determine the optimal capacitance for active power decoupling circuits to achieve high power density. Minimum capacitance is derived by analyzing ripple power in a passive power decoupling circuit, a buck-type circuit, and a capacitor-split-type circuit. Double-frequency ripple power decoupling capabilities are also analyzed in three decoupling circuits under a 3.3 kW load condition for a battery charger application. To verify the proposed design method, the performance of the three decoupling circuits with the derived minimum capacitance is compared and analyzed through the results of MATLAB -Simulink and hardware-in-the-loop simulations.

Design of Three-port Flyback Inverter for Active Power Decoupling (능동 전력 디커플링을 위한 3권선 방식의 플라이백 인버터 설계)

  • Kim, Kyu-Dong;Kim, Jun-Gu;Lee, Tae-Won;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.486-487
    • /
    • 2012
  • In this paper, novel three-port active power decoupling (APD) method for applying 250[W] micro-inverter. This type using third port for active power decoupling stores the surplus energy and supplies sufficient energy to grid. Conventional decoupling circuit is applied in single phase grid connected micro-inverter especially single-stage configuration like flyback-type DC-AC inverter. In this passive power decoupling method, electrolytic capacitor with large capacitance is needed for decoupling from constant DC power and instantaneous AC power. However the decoupling capacitor is replaced with film capacitor by using APD, thus the overall system can achieve smaller size and long lifespan. Proposed three-port flyback inverter is verified by design and simulation.

  • PDF

Optimal Wiener-Hopf Decoupling Controller Formula for State-space Algorithms

  • Park, Ki-Heon;Kim, Jin-Geol
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.4
    • /
    • pp.471-478
    • /
    • 2007
  • In this paper, an optimal Wiener-Hopf decoupling controller formula is obtained which is expressed in terms of rational matrices, thereby readily allowing the use of state-space algorithms. To this end, the characterization formula for the class of all realizable decoupling controller is formulated in terms of rational functions. The class of all stabilizing and decoupling controllers is parametrized via the free diagonal matrices and the optimal decoupling controller is determined from these free matrices.

Decoupling Controller Design for H Performance Condition

  • Park, Tae-Dong;Choi, Goon-Ho;Cho, Yong-Seok;Park, Ki-Heon
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.874-882
    • /
    • 2011
  • The decoupling design for the one-degree-of-freedom controller system is treated within the $H_{\infty}$ framework. In the present study, we demonstrate that the $H_{\infty}$ performance problem in the decoupling design is reduced into interpolation problems on scalar functions. To guarantee the properness of decoupling controllers and the overall transfer matrix, the relative degree conditions on the interpolating scalar functions are derived. To find the interpolating functions with relative degree constraints, Nevanlinna-Pick algorithm with starting function constraint is utilized in the present study. An illustrative example is given to provide details regarding the solution.

On-chip Decoupling Capacitor for Power Integrity (전력 무결성을 위한 온 칩 디커플링 커패시터)

  • Cho, Seungbum;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.1-6
    • /
    • 2017
  • As the performance and density of IC devices increase, especially the clock frequency increases, power grid network integrity problems become more challenging. To resolve these power integrity problems, the use of passive devices such as resistor, inductor, and capacitor is very important. To manage the power integrity with little noise or ripple, decoupling capacitors are essential in electronic packaging. The decoupling capacitors are classified into voltage regulator capacitor, board capacitor, package capacitor, and on-chip capacitor. For next generation packaging technologies such as 3D packaging or wafer level packaging on-chip MIM decoupling capacitor is the key element for power distribution and delivery management. This paper reviews the use and necessity of on-chip decoupling capacitor.

A Study on a Sufficient Condition for Decoupling Control System Design (입력과 출력간의 비간섭 제어계 설계에 관한 연구)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.84-88
    • /
    • 1999
  • In this paper, systems described by state-space models are considered. For these systems, author studies the decoupling of linear systems and gives a sufficient condition for a system to be made feedback decouplable. Especially, the condition is given by LMI(Linear Matrix Inequality) form. Based on this condition, it is guaranteed that the system decoupling problem is achieved and the $H_{\infty}$ constraint is satisfied simultaneously. This result can be easily extended to the robust decoupling control system design problems.

  • PDF

Design and Analysis of an Improved Decoupling Feedforward Controller for Speed Control of SynRM (초고속 전동기 속도제어를 위한 개선된 비간섭 피드-포워드 제어기 설계 및 해석)

  • Oh, Sung-Up;Kim, In-Soo;Seong, Se-Jin;Choi, Jae-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.864-867
    • /
    • 2003
  • In this study, a controller which has a feedforward controller and two additional PI integrators was designed. But if a controller is used by only the integration of a feedforward controller and two additional PI integrators, the capability of a controller will decrease because the decoupling terms of current is feedback as the disturbance. Therefore the feedforward method with the decoupling compensation was proposed. The two additional PI integrators were replaced by two decoupling terms to simplify the calculation. The simulation and experimental using SynRM driving system were performed to verify the design of a improved decoupling feedforward controller.

  • PDF

Analysis and Design of a Three-port Flyback Inverter using an Active Power Decoupling Method to Minimize Input Capacitance

  • Kim, Jun-Gu;Kim, Kyu-Dong;Noh, Yong-Su;Jung, Yong-Chae;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.558-568
    • /
    • 2013
  • In this paper, a new decoupling technique for a flyback inverter using an active power decoupling circuit with auxiliary winding and a novel switching pattern is proposed. The conventional passive power decoupling method is applied to control Maximum Power Point Tracking (MPPT) efficiently by attenuating double frequency power pulsation on the photovoltaic (PV) side. In this case, decoupling capacitor for a flyback inverter is essentially required large electrolytic capacitor of milli-farads. However using the electrolytic capacitor have problems of bulky size and short life-span. Because this electrolytic capacitor is strongly concerned with the life-span of an AC module system, an active power decoupling circuit to minimize input capacitance is needed. In the proposed topology, auxiliary winding defined as a Ripple port will partially cover difference between a PV power and an AC Power. Since input capacitor and auxiliary capacitor is reduced by Ripple port, it can be replaced by a film capacitor. To perform the operation of charging/discharging decoupling capacitor $C_x$, a novel switching sequence is also proposed. The proposed topology is verified by design analysis, simulation and experimental results.

Conceptual Design of a Beam Splitter for the Laser Marker Using Axiomatic Design and Triz (TRIZ를 도입한 공리적 설계방법에 의한 레이저 마커의 빔 분해기 개념설계)

  • 신광섭;박경진
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.166-173
    • /
    • 2004
  • Axiomatic Design has been developed as a general design framework during past two decades and TRIZ has been developed for a design tool over 50 years. Axiomatic design is quite excellent in that the design should be decoupled. When a design matrix is established, the characteristics of the design are identified concerning the coupling properties. If the design is coupled, a decoupling process should be found. However, axiomatic design does not specifically indicate how to decouple. In this paper, a design method is developed to use TRIZ in the decoupling process. The decoupling ideas are extracted from the substance field analysis and various methods in TRIZ. The mettled is applied applied to the conceptual design of a beam splitter for the laser marker and the results are analyzed.

Decoupling Control Design for Variable Speed Refrigeration System of a Ship

  • Hua, Li;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.7
    • /
    • pp.808-815
    • /
    • 2006
  • In this paper, we suggest decoupling control method based on general PI control law to control variable speed refrigeration system of the ship effectively. In the variable speed refrigeration system, the capacity and the superheat are controlled by inverters and electronic expansion valves respectively for saving energy and improving cost performance. Thus, we propose decoupling model to eliminate the interfering loop between capacity and superheat at first. Next, we design PI controller to control capacity and superheat independently and simultaneously. Finally the control performance was investigated through some experiments. The experimental results show that the PI control design can obtain good control performance under the adjustable control reference and thermal load variation.