• Title/Summary/Keyword: Coupling Image

Search Result 85, Processing Time 0.023 seconds

Time-Multiplexed RF Transmission to Improve $B_1$ Homogeneity in High Field MRI

  • Han, Byung-Hee;Seo, Jeung-Hun;Heo, Hye-Young;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.99-106
    • /
    • 2008
  • To improve $B_1$ homogeneity in high field MRI, the RF power is applied to the transmit array coil elements sequentially in the time-multiplexed way. Since only a single coil element is activated in a time-multiplexing slot, the global standing wave formation in the human body is greatly suppressed. The time-multiplexing slot width is on the order of micro seconds, hence, high-order-harmonic slices can be placed far from the transmit coil and simultaneous multiple slice selection can be avoided. The $B_1$ homogeneities of a birdcage coil and an eight-channel transmit array coil have been compared through finite difference time domain simulations. The simulation results indicate that the proposed technique can reduce the peak-to-peak $B_1$ inhomogeneity down to one fourth of the transmission with a birdcage coil on the central plane of the human head model at 3 T. The mimicking experiments at 3 T, eight separate experiments with a single coil element activated and image reconstruction by combining the eight images, also show promising results. It is expected that the proposed technique has some advantages over other $B_1$ improving methods in real practice since simple RF switching circuitries are only necessary and electromagnetic coupling between the coil elements is out of concern in its realization.

Differential Capacitor-Coupled Successive Approximation ADC (차동 커패시터 커플링을 이용한 연속근사 ADC)

  • Yang, Soo-Yeol;Mo, Hyun-Sun;Kim, Dae-Jeong
    • Journal of IKEEE
    • /
    • v.14 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This paper presents a design of the successive approximation ADC(SA-ADC) applicable to a midium-low speed analog-front end(AFE) for the maximum 15MS/s CCD image processing. SA-ADC is effective in applications ranging widely between low and mid data rates due to the large power scaling effect on the operating frequency variations in some other way of pipelined ADCs. The proposed design exhibits some distinctive features. The "differential capacitor-coupling scheme" segregates the input sampling behavior from the sub-DAC incorporating the differential input and the sub-DAC output, which prominently reduces the loading throughout the signal path. Determining the MSB(sign bit) from the held input data in advance of the data conversion period, a kind of the signed successive approximation, leads to the reduction of the sub-DAC hardware overhead by 1 bit and the conversion period by 1 cycle. Characterizing the proposed design in a 3.3 V $0.35-{\mu}m$ CMOS process by Spectre simulations verified its validity of the application to CCD analog front-ends.

Imaging on a Vapor Deposited Film by Photopolymerization of a Rod-Like Molecule Consisting of Two Diacetylenic Groups

  • Chang, Ji-Young;Kyung Seo;Cho, Hyun-Ju;Lee, Cheol-Ju;Lee, Changjin;Yongku Kang;Kim, Jaehyung
    • Macromolecular Research
    • /
    • v.10 no.4
    • /
    • pp.204-208
    • /
    • 2002
  • A linear rod-like molecule, bis[4-(1,3-octadynyl)phenyl] terephthalate (2), consisting of two diacetylenic groups, was prepared. The unsymmetric diacetylene was prepared by the Cadiot-Chodkiewicz coupling reaction of 1-bromohexyne with 4-ethynylphenol and linked to a benzene core by an esterification reaction with terephthaloyl chloride in tetrahydrofuran. The thin film (200 nm thickness) of compound 2 was fabricated by the physical vapor deposition on a glass plate with a thermal evaporator. In the X-ray diffraction (XRD) study, the vapor deposited film on the glass plate showed peaks with d spacings of 19.4, 5.7, and 4.5 $\AA$. This XRD pattern was quite different from that observed for compound 2 isolated by recrystallization from methylene chloride/hexane. The vapor deposited film was polymerized by UV irradiation. Photopolymerization was carried out through a photomask, resulting in a patterned image, where the irradiated part became isotropic.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

Effects of KNbO3-Substitution on the Dielectric and Piezoelectric Properties of (Li,Na,K)(Nb,Sb,Ta)O3 System Ceramics (KNbO3 치환이 (Li,Na,K)(Nb,Sb,Ta)O3계 세라믹스의 유전 및 압전 특성에 미치는 영향)

  • Noh, Jungrae;Yoo, Ju-Hyun;Lee, Sang-Don
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.3
    • /
    • pp.204-208
    • /
    • 2013
  • In this study, $KNbO_3$-substituted (Li,Na,K)(Nb,Sb,Ta)$O_3$ ceramics were investigated to develop Pb-free composition ceramics for multilayer actuator and energy harvester applications. The X-ray diffraction analysis indicated that all samples were pure perovskite phase and no secondary phase was found. A tetragonality as a function of $KNbO_3$ substitution showed the maximum value at 1.5 mol% $KNbO_3$ and then decreased. The SEM image analysis showed the maximum grain size of $3.14{\mu}m$ at 1.5mol% $KNbO_3$. In the composition ceramics with 1.5 mol% $KNbO_3$ sintered at $1,100^{\circ}C$, excellent properties of density= 4.75 $g/cm^3$, electromechanical coupling factor ($k_p$)= 0.50 and piezoelectric constant($d_{33}$)= 290 pC/N were obtained, respectively, suitable for piezoelectric actuator and energy harvester applications.

Design and Development of a Single-photon Laser and Infrared Common Aperture Optical System

  • Wu, Hongbo;Zhang, Xin;Tan, Shuanglong;Liu, Mingxin;Wang, Lingjie;Yan, Lei;Liu, Yang;Shi, Guangwei
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • A single-photon laser and mid-wave infrared (MWIR) common aperture optical system was designed and developed to detect and range a long-distance civil aviation aircraft. The secondary mirror of the Ritchey-Chretien (R-C) optical system was chosen as a dichroic lens to realize the design of a common aperture system for the laser and MWIR. Point spread function (PSF) ellipticity was introduced to evaluate the coupling efficiency of the laser receiving system. A small aperture stop and narrow filter were set in the secondary image plane and an afocal light path of the laser system, respectively, and the stray light suppression ability of the small aperture stop was verified by modeling and simulation. With high-precision manufacturing technology by single point diamond turning (SPDT) and a high-efficiency dichroic coating, the laser/MWIR common aperture optical system with a 𝜑300 mm aluminum alloy mirror obtained images of buildings at a distance of 5 km with great quality. A civil aviation aircraft detection experiment was conducted. The results show that the common aperture system could detect and track long-distance civil aviation aircraft effectively, and the coverage was more than 450 km (signal-to-noise ratio = 6.3). It satisfied the application requirements for earlier warning and ranging of long-range targets in the area of aviation, aerospace and ground detection systems.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Changes of Facial Wrinkle after Topical Application of On Emulsion Containing Medimin A (Medimin A를 함유한 O/W 에멀전의 주름 개선 효과)

  • 박선규;장민열;김영득;정봉열;원영호;김진준;강세훈
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.1
    • /
    • pp.23-36
    • /
    • 1999
  • Medimin A is a derivative of vitamin A which has been developed by coupling retinoic acid with polyethylene glycol(PEG) to enhance skin permeability and stability. We carried out the collagen synthesis and clinical test to examine the reducing effect of wrinkles by Medimin A. In vitro collagen synthesis was evaluated by quantitative assay of ($^3$H)-proline incorporation into collagenase sensitive protein in fibroblast cultures. Clinical test was evaluated by image analysis of skin replica, visual observation and self-estimated response of volunteers for 10 weeks. Medimin A stimulated about 40% in collagen synthesis. The area of main deep wrinkle on the skin replica was reduced 38.4% with topical application of O/W emulsion containing 0.2% Medimin A. The wrinkles on the eye region was also reduced 25.4%-44.1% by the visual observation and 93% of all volunteers responded that topical application of the O/W emulsion was showed some reducing effect of wrinkles after 10 weeks. From these results, we suggest that Medimin A is a potent anti-wrinkle agent by objective evaluation methods(in vitro collagen synthesis and image analysis of skin replica) and subjective evaluation methods(visual observation and self-estimated response of volunteers).

  • PDF

Study on Improvement of Oil Spill Prediction Using Satellite Data and Oil-spill Model: Hebei Spirit Oil Spill (인공위성 원격탐사 데이터와 수치모델을 이용한 해상 유출유 예측 향상 연구: Hebei Spirit호 기름 유출 적용)

  • Yang, Chan-Su;Kim, Do-Youn;Oh, Jeong-Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.5
    • /
    • pp.435-444
    • /
    • 2009
  • In the case of oil spill accident at sea, information concerning the movement of spilled oil is important in making response strategies. Aircrafts and the satellites have been utilized for monitoring of spilled oil. In these days, numerical models are using to predict the movement of the spilled oil. In the future a coupling method of modeling and remote sensing data should be needed to predict more correctly the spilled oil. The purpose of this paper is to present an application of satellite image data to an oil spill prediction model as an initial condition. Environmental Fluid Dynamics Computer Code (EFDC) was used to predict the movement of the oil spilled from Hebei Spirit incident occurred in Taean coastal area on December 7,2007. In order to make the model initial condition and to compare the model results, two satellite images, KOMPSAT-2 MSC and ENVISAT ASAR obtained on December 8 and 11, were used during the period of the oil spill incident. The model results showed an improvement for the prediction of the spilled oil by using the initial condition deduced from satellite image data than the initial condition specified at the oil spill incident site in the respects of the distributed spilled area.

Delamination Evaluation of Thermal Barrier Coating on Turbine Blade owing to Isothermal Degradation Using Ultrasonic C-scan Image (초음파 C-scan을 이용한 터빈 블레이드 열차폐코팅의 등온열화에 의한 박리 평가 기법)

  • Lee, Ho-Girl;Kim, Hak-Joon;Song, Sung-Jin;Seok, Chang-Sung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.353-362
    • /
    • 2016
  • Thermal barrier coating (TBC) is an essential element consisting of a super-alloy base and ceramic coating designed to achieve long operational time under a high temperature and pressure environment. However, the top coat of TBC can be delaminated at certain temperatures with long operation time. As the delamination of TBC is directly related to the blade damage, the coupling status of the TBC should be assured for reliable operation. Conventional studies of nondestructive evaluation have been made for detecting generation of thermally grown oxide (TGO) or qualitatively evaluating delamination in TBC. In this study, the ultrasonic C-scan method was developed to obtain the damage map inside TBC by estimating the delamination in a quantitative way. All specimens were isothermally degraded at $1,100^{\circ}C$ with different time, having different partial delamination area. To detect partial delamination in TBC, the C-scan was performed by a single transducer using pulse-echo method with normal incidence. Partial delamination coefficients of 1 mm to 6 mm were derived by the proportion of the surface reflection signal and flaw signal which were theoretical signals using Rogers-Van Buren and Kim's equations. Using the partial delamination coefficients, the partial delamination maps were obtained. Regardless of the partial delamination coefficient, partial delamination area was increased when degradation time was increased in TBC. In addition, a decrease in partial delamination area in each TBC specimen was observed when the partial delamination coefficient was increased. From the portion of the partial delamination maps, the criterion for delamination was derived.