• 제목/요약/키워드: Contact diameter

검색결과 491건 처리시간 0.026초

플립칩용 웨이퍼레벨 Fine Pitch 솔더범프 형성 (Fabrication of Wafer Level Fine Pitch Solder Bump for Flip Chip Application)

  • 주철원;김성진;백규하;이희태;한병성;박성수;강영일
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.874-878
    • /
    • 2001
  • Solder bump was electroplated on wafer for flip chip application. The process is as follows. Ti/Cu were sputtered and thick PR was formed by several coating PR layer. Fine pitch vias were opened using via mask and then Cu stud and solder bump were electroplated. Finally solder bump was formed by reflow process. In this paper, we opened 40㎛ vias on 57㎛ thick PR layer and electroplated solder bump with 70㎛ height and 40㎛ diameter. After reflow process, we could form solder bump with 53㎛ height and 43㎛ diameter. In plating process, we improved the plating uniformity within 3% by using ring contact instead of conventional multi-point contact.

  • PDF

마이크로 기둥 구조의 크기가 소유성 특성 발현에 미치는 영향 (The Effect of Dimensions of Micro-post on Oleophobic Property)

  • 김남경;김해지
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.91-96
    • /
    • 2018
  • The oleophobic property of surfaces modified with micro-post structures are investigated for a range of micro-post diameter ($11-23{\mu}m$) and pitch ($20-40{\mu}m$). The contact angle of an oil droplet on surfaces with various micro-post dimensions was calculated using the Cassie-Baxter model and did not show a good agreement with the measured contact angle. From measurement, the micro-post with diameter of $23{\mu}m$ and pitch of $32{\mu}m$ was found to have the highest contact angle ($134.3^{\circ}$).

나노기공 표면에서의 세포 행동양식에 관한 연구 (Investigation of Cell Behavior on Nanoporous Surface)

  • 정성희;윤원중;민준홍
    • KSBB Journal
    • /
    • 제27권1호
    • /
    • pp.45-50
    • /
    • 2012
  • In this paper, we investigated the effect of nanostructure on the cell behaviors such as adhesion and growth rate. Nanoporous structures with various diameters (30, 40, 45, 50, 60 nm) and 500 nm of the depth were fabricated using the anodizing method. The water contact angle of the surface consisting of nanopores with 30 nm diameter was 40 degree and those were 60~70 degree in cases of nanopores with over 40 nm diameter. Hela cells were cultivated on various nanoporous structure surface to investigate the cell behavior on nanostructure. As a result, Hela cells preferred 30 nm diameter nanoporous surface that has lower water contact angle. This result was confirmed by protein adsorption experiment and scanning electron microscope investigation.

골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE)

  • 장경수;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF

Calculating the Contact Stress Resulting from Lateral Movement of the Wheel on Rail by Applying Hertz Theory

  • Ashofteh, Roya Sadat
    • International Journal of Railway
    • /
    • 제6권4호
    • /
    • pp.148-154
    • /
    • 2013
  • This article has tried to review the maximum contact stresses in the contact area of the wheel and rail as a result of lateral movement of the wheel on rail by taking advantage from Hertz theory. Since wheel movement on rail is accompanied by lateral movement due to wheel profile conisity, so the contact point of wheel and rail is not constant and the contact stresses are therefore changeable in every single moment. Since the shape of rail profile and rail inclination, wheel diameter and the mechanical properties of the wheel and rail are effective on the stresses of contact area, these parameters have been studied by applying Hertz theory. This article aims to calculate the contact stresses in different parts on the wheel surface by using Hertz theory.

성견에서 사다리꼴형 디자인과 미세나사선을 가진 단폭경임플란트의 골유착 평가: 예비연구 (Evaluation of narrow-diameter implant with trapezoid-shape design and microthreads in beagle dogs: A pilot study)

  • 장윤영;윤정호
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.529-540
    • /
    • 2016
  • Objective: The objective of this study was to evaluate the osseointegration of narrow-diameter implant with trapezoid-shape and to evaluate the effect of coronal microthreads on trapezoid-shape narrow-diameter implant. Materials and Methods: The experimental narrow-diameter implants were classified into two groups according to absence or presence of coronal microthreads: trapezoid-shape narrow diameter implant (TN group) and trapezoid-shape narrow-diameter implant with microthreads (TNM group). They were installed alternately in bilateral mandible in three dogs. After 8 weeks, the animals were sacrificed. Resonance frequency analysis, removal torque test, and histometric analysis were performed. Results: Statistically higher implant stability quotient (ISQ) values were observed in TNM group than in TN group at the time of implant installation. However, significant ISQ values difference was not observed between groups at 8 weeks. Both groups showed significantly increased ISQ values at 8 weeks, compared to the time of implant installation. There was no significant difference between groups in removal torque test. Bone-implant contact ratio also showed no significant difference between groups in total and coronal part. Conclusion: Within the limitation of this study, it could be concluded that the trapezoid-shape design on narrow-diameter implant showed successful ossointegration, and the microthreads on coronal part did not result in significant bone-implant contact and biomechanical stability at 8 weeks.

  • PDF

단 측벽 구속하에서 압축 및 내압을 받는 고무 오링의 설계 민감도 연구 (A Study on Design Sensitivity of Elastomeric O-ring Squeezed and Highly Pressurized Under Laterally One-sided Constrained Condition)

  • 박성한;김재훈;김원훈
    • 한국안전학회지
    • /
    • 제22권6호
    • /
    • pp.27-34
    • /
    • 2007
  • Static or dynamic elastomeric O-ring seals are installed between joining parts, and play key roles of high pressure-tightening. Sealing performance and structural safety of the O-ring are dependent on groove design, plain diameter, squeeze and applications such as pressure and temperature. In this study, to solve O-ring problem squeezed and highly pressurized under laterally one-sided constrained condition, hyperelastic FE analyses are performed, and FE results are compared with measured ones by computer-aided tomography, deformed shape and extrusion depth of the O-ring. Through the comparisons, FE analysis technique was verified. In order to evaluate design sensitivity, Taguchi method was used to select FE analysis cases. Adjustment parameters are clearance gap, groove comer radius, plain diameter and squeeze. By means of verified FE analysis technique, it has been analysed how the parameters have effects on contact stress fields, internal stress fields, and extrusion depths. Sealing performance has been evaluated based on contact stress fields and contact widths, and structural safety on internal stress and strain, extrusion lengths.

이중 O링의 접촉거동 해석에 관한 수치적 연구 (A Numerical Study on the Contact Behavior Analysis of Double Layer O-rings)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • 제19권1호
    • /
    • pp.9-14
    • /
    • 2003
  • The sealing performance of an elastomeric O-ring using the double layered material has been analyzed fer the contact stress behaviors that develop between the O-ring seal and the surfaces with which it comes into contact. The leakage of an O-ring will occur when the pressure differential across the seal Just exceeds the initial (or static) peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of dovetail grooved geometry, are investigated using the finite element method. The FE analysis includes material hyperelasticity and axisymmetry. The computed FEM results show that the contact stress behaviors are related to the ratio of diameter between the inner ring and the outer ring, and the temperature of vacuum chamber.

기하학적 원리에 의거한 접촉각의 측정 (Development of a Contact Angle Measurement Method Based Upon Geometry)

  • 김동수;표나영;서승희;최우진;권영식
    • 자원리싸이클링
    • /
    • 제7권5호
    • /
    • pp.41-45
    • /
    • 1998
  • 간단한 기하학적 원리에 의해 접촉각을 계산할 수 있는 방안을 모색하였다. 접촉각 측정에 일반적으로 이용되는 기기를 사용하지 않고, 단지 고체 표면의 용액 렌즈가 형성하는 접촉원의 지름과 렌즈의 높이를 측정함으로써 상당한 신뢰성을 가진 접촉각의 크기를 계산할 수 있었다. 이 방법의 신뢰성을 확인하기 위하여 동일한 용액 렌즈에 대해 일반적인 접촉각 측정 장치로 접촉각을 측정하여 그 값들을 상호 비교한 결과 오차 한계의 범위내에서 거의 일치함을 확인하였다.

  • PDF