Acknowledgement
Supported by : 산업통상자원부
References
- Zinsli B, Sagesser T, Mericske E, Mericske-Stern R. Clinical evaluation of small-diameter ITI implants: a prospective study. Int J Oral Maxillofac Implants 2004;19(1):92-99.
- Ding X, Liao SH, Zhu XH, et al. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants. Clin Implant Dent Relat Res 2009;11(4):279-287. https://doi.org/10.1111/j.1708-8208.2008.00124.x
- Kobayashi E, Matsumoto S, Doi H, et al. Mechanical properties of the binary titaniumzirconium alloys and their potential for biomedical materials. J Biomed Mater Res 1995;29(8):943-950. https://doi.org/10.1002/jbm.820290805
- Thoma DS, Jones AA, Dard M, et al. Tissue integration of a new titanium-zirconium dental implant: a comparative histologic and radiographic study in the canine. J Periodontol 2011;82(10):1453-1461. https://doi.org/10.1902/jop.2010.100737
- Anchieta RB, Baldassarri M, Guastaldi F, et al. Mechanical property assessment of bone healing around a titanium-zirconium alloy dental implant. Clin Implant Dent Relat Res 2014;16(6):913-919. https://doi.org/10.1111/cid.12061
- Chang YY, Kim SH, Park KO, Yun JH. Evaluation of a reverse-tapered design on the osseointegration of narrow-diameter implants in beagle dogs: a pilot study. Int J Oral Maxillofac Implants 2016;31:611-620.
- Schropp L, Wenzel A, Kostopoulos L, Karring T. Bone healing and soft tissue contour changes following single-tooth extraction: a clinical and radiographic 12-month prospective study. Int J Periodontics Restorative Dent 2003;23(4):313-323.
- Abuhussein H, Pagni G, Rebaudi A, Wang HL. The effect of thread pattern upon implant osseointegration. Clin Oral Implants Res 2010;21(2):129-136. https://doi.org/10.1111/j.1600-0501.2009.01800.x
- Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1(1):11-25.
- Kong L, Hu K, Li D, et al. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2008;23(1):65-74.
- Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10(5):394-405. https://doi.org/10.1034/j.1600-0501.1999.100506.x
- Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs. Clin Implant Dent Relat Res 2006;8(3):107-113. https://doi.org/10.1111/j.1708-8208.2006.00016.x
- Hudieb MI, Wakabayashi N, Kasugai S. Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant. J Periodontol 2011;82(7):1061-1070. https://doi.org/10.1902/jop.2010.100237
- Shin YK, Han CH, Heo SJ, et al. Radiographic evaluation of marginal bone level around implants with different neck designs after 1 year. Int J Oral Maxillofac Implants 2006;21(5):789-794.
- Bratu EA, Tandlich M, Shapira L. A rough surface implant neck with microthreads reduces the amount of marginal bone loss: a prospective clinical study. Clin Oral Implants Res 2009;20(8):827-832. https://doi.org/10.1111/j.1600-0501.2009.01730.x
- Suh JY, Jeung OC, Choi BJ, Park JW. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae. Clin Oral Implants Res 2007;18(3):362-369. https://doi.org/10.1111/j.1600-0501.2006.01323.x
- Park JW, Park KB, Suh JY. Effects of calcium ion incorporation on bone healing of Ti6Al4V alloy implants in rabbit tibiae. Biomaterials 2007;28(22):3306-3313. https://doi.org/10.1016/j.biomaterials.2007.04.007
- Botticelli D, Berglundh T, Buser D, Lindhe J. The jumping distance revisited: An experimental study in the dog. Clin Oral Implants Res 2003;14(1):35-42. https://doi.org/10.1034/j.1600-0501.2003.140105.x
- Botticelli D, Berglundh T, Buser D, Lindhe J. Appositional bone formation in marginal defects at implants. Clin Oral Implants Res 2003;14(1):1-9. https://doi.org/10.1034/j.1600-0501.2003.140101.x
- Davies JE. Mechanisms of endosseous integration. Int J Prosthodont 1998;11(5):391-401.
- Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47:51-66. https://doi.org/10.1111/j.1600-0757.2008.00267.x
- Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res 2003;14(3):251-262. https://doi.org/10.1034/j.1600-0501.2003.00972.x
- Festing M, Overend P, Gaines D, R, et al. The design of animal experiments: reducing the use of animals in research through better experimental design. 1 ed. London: Royal Society of Medicine, 2002.