• Title/Summary/Keyword: Construction facility

Search Result 1,626, Processing Time 0.031 seconds

The Application and Seismic Design Method of Electrical Facility Installed in the Building (건축물에 시설되는 수변전설비의 내진설계 검토사항 및 설계 방안에 대한 고찰)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong;Cho, Sung-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.74-79
    • /
    • 2009
  • In the case of that not considered seismic design at transformer vault which is equipped with many important electrical facilities, the facility is damaged, electrical fire breaks out and another damage may be caused due to earthquake. But seismic design has not yet applied to transformer vault in the country. Regard to seismic design method of electrical facility installed inside the building, the seismic design procedures for electrical facility is presented in this parer, which has been developed by referring "Building design standard" of domestic code and "Manual of seismic design and construction for building electrical facility" in japan. This paper may help engineers perform detail seismic design, construction and reliability inspection of electrical pipes and facilities.

Guidelines for the Establishment and Vitalization Scheme on Facility of Nature Environmental Conservation and its Utilization (자연환경보전·이용시설 가이드라인 및 활성화방안)

  • Choi, Jaeyong;Park, Sohyun;Lee, Dong Kun;Shin, Kyungjoon;Hong, Taesik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.4
    • /
    • pp.36-51
    • /
    • 2006
  • Although the demand and necessity for the facilities of nature environmental conservation and its utilization have been increased recently, the local governments has been experiencing difficulties to launch the facilities since there are no confirmed principles or guidelines for the direction of the facility and distinctions from the ordinary parks. In this regard, the aim of this paper is to provide the overall framework for establishing the facility by equipping checklists from planning to operational stage. The stages are disengaged into 5 steps of siting feasibility, planning, preliminary environmental assessment and environmental impact assessment, design, construction, and operation. This paper also include the recommendations to vitalize the existing facilities, of which expansion of educational program development; utilization of various manpower; provision of appropriate settings; strengthened monitoring; and increased public relations. Furthermore, it is suggested to consider the strengthened local characteristics, reviewing management plan at the stage of applying a new facility establishment to the concerned authority, fostering experts, and expansion of the facilities through restoration of environmentally damaged areas for a new facility.

Propose an Improvement of Checklist for Actual Condition Survey for Designation of Class-lll Facilitie (제3종시설물 지정을 위한 실태조사 체크리스트 개선방안)

  • Yoon, Ji-Ho;Jang, Myunghoun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.100-101
    • /
    • 2021
  • Facilities with high risk of a disaster or requiring continuous safety management are designated as class-III facility. In order to designate a class-III facility, it is evaluated based on the safety status of the facility, the risk to the building users, and the number of years elapsed of the facility, etc. and this shall be referred to the actual condition survey for the designation of a class-III facility. In the actual condition survey conducted to designate the safety status is calculated by the checklist based on the evaluation scores consisting of five stages each item, and is evaluated in three stages by 'good', 'careful observation', and 'designated review' through the average of the combined scores. Currently, the actual condition survey being conducted applies only structural stability, and the risk factors such as damage to the finish, the risk of cracking, and the type and weight of major structures are not included in the checklist for the actual condition survey, so even if experts think it is dangerous, scores cannot be reflected. Therefore, this study aims to analyze the problems of checklist of the actual condition survey for the designation of class-III facility and to propose an improvement plan for the checklist for the actual condition survey.

  • PDF

A study on the space composition and area planning of neonatal intensive care unit through the case of regional neonatal intensive care centers (신생아 집중치료 지역센터 사례를 통해 본 신생아 집중치료실(NICU) 공간 구성 및 면적 계획에 관한 연구)

  • Lee, Kee hwan;Park, Seo won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.1
    • /
    • pp.7-17
    • /
    • 2024
  • Purpose: This study is to present basic data and standards for calculating the space composition and area required when planning a neonatal intensive care unit. Methods: Review domestic and foreign facility standards and regulations related to the current neonatal intensive care unit, select a regional neonatal intensive care center designated by the Ministry of Health and Welfare as a case hospital, and organize a space program for the construction plan of the neonatal intensive care unit through analysis of characteristics such as facility size and function composition. Results and Implications: The size, facility area, and detailed room composition characteristics of the neonatal intensive care unit in Korea were confirmed, and essential rooms and appropriate areas were derived when planning the construction of the neonatal intensive care unit. Korea's legal facility standards related to neonatal intensive care units are lower than the actual hospital status and overseas standards, and the facility standards of the medical law need to be improved.

An Economy Analysis on the Underground Food Storage (농수축산물저장을 위한 지하암반냉동창고의 경제성분석)

  • 김준홍
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.19 no.38
    • /
    • pp.189-197
    • /
    • 1996
  • It is in general reported that construction cost in an underground storage facility is less than that of the same capacity and features in an aboveground facility. Since these costs have a derivative with respect to facility size and fridging unit, the cost of construction and fridging unit are sensitive to location of storage, items to store, and rock quality of storage site. In this paper, to analyse an economic investment point for the underground food storage relative to aboveground storage, we compared these two models which have equivalent annual cost with the total cost that consists of initial facility investment cost and annual operation cost. Based on comparison of the economic investment in the underground with aboveground storage. an economic initial investment cost has been suggested for storing the agricultural and fish products.

  • PDF

The Study on the Safety Adhesion Test of Wet Surface for Waterproofing and Anti Corrosion Materials of Water Supply Facility (수처리 시설물에 적용되는 방수·방식재의 습윤면 부착 안정 성능평가방법에 대한 연구)

  • Choi, Su-Young;Kim, Dong-Bum;Park, Jin-Sang;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.137-138
    • /
    • 2017
  • The Waterproofing and Anti corrosion materials applied to the water supply facility did not consider environment of water supply facility, thus defects occurred consistently on the site. In this study, it suggests safety adhesion test of wet surface and have a test for safety adhesion performance.

  • PDF

A Study on the Improvement of Evacuation Measures through the Analysis of Fire Incident in the Facility of People Vulnerable to Disaster (재난약자시설의 화재사례 분석을 통한 피난대책 개선에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.78-79
    • /
    • 2018
  • The facilities of domestic elderly people are getting higher in the facility due to the rapid increase of the elderly population. Elderly people ability to evacuate the facility such as cognition and walking ability is very low. Therefore, it is necessary to secure the safety of evacuation in case of fire, but the evacuation safety measures in case of domestic fire accidents are insufficient. This study is to identify the problems of the safety of evacuation through the fire case analysis and to propose the measures against it.

  • PDF

A Basic Study on School Facility Management for Violence Prevention Based on CPTED Method (CPTED이론을 적용한 학교시설물 유지관리 방안 기초연구)

  • Kim, Boo-Young;Son, Kiyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.112-113
    • /
    • 2013
  • For prevention of the school violence, many researchers have been conducted the studies based on crime prevention through environment design(CPTED) in the architecture planning phase. However, besides of architecture planning, the study considering the aspect of the facility management is needed during life cycle of educational facilities. In this study, the objective is to propose the effective school facility management for violence prevention based on CPTED method during life cycle of the facilities.

  • PDF

DESIGN AND CONSTRUCTION OF AN ADVANCED SPENT FUEL CONDITIONING PROCESS FACILITY (ACPF)

  • You, Gil-Sung;Choung, Won-Myung;Ku, Jeong-Hoe;Cho, Il-Je;Kook, Dong-Hak;Kwon, Kie-Chan;Lee, Eun-Pyo;Lee, Won-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.859-866
    • /
    • 2009
  • KAERI has worked on the development of an advanced spent fuel conditioning process (ACP) since 1997. A hot cell facility, termed the ACPF, has also been developed. The ACPF consists of two air-sealed hot cells. The results of a safety analysis as part of the license procurement process stipulated by the Korean Government showed that the facility was designed safely. After its construction, an integrated performance test was performed. The results of this test confirmed that the facility satisfies the design requirements.

SPACE STRUCTURE ANALYSIS OF COMPLEX CULTURE SHOPPING FACILITY.

  • Jae-Hong Hwang;Byung-ju Ank;Whoi-yul Kim;Jae-Joon Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1128-1133
    • /
    • 2009
  • Recently super complex culture shopping facility development seeks consumer' convenience present and are coming restaurant neighborhood, cinema, shopping, hotel etc, according to intensive plan. Such as complex culture shopping facility was developed to most subway station area center and have concept that is space for a main facilities or space for environment protection, citizens' a rest in city. Howeve,r space of recently domestic large size complex culture shopping facility that do not plan systematically was lacking and caused result that do not use efficiently space. Limited extent of research that define complex culture shopping equipment and analyze form of space and present space planning with analysis of research connected with complex usage development.

  • PDF