• Title/Summary/Keyword: Construction facility

Search Result 1,627, Processing Time 0.027 seconds

A Study on the Adhesion Performance of Solid Forming Angle at Fiber Panel in the Water Supply Facility (수처리 시설물에 적용되는 섬유패널 배면부의 입체 성형 각도에 따른 부착 성능 연구)

  • Youn, Joon-No;Park, Wan-Goo;Choi, Su-Young;Kim, Dong-Bum;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.171-172
    • /
    • 2018
  • The purpose of this study is to confirm the adhesion performance of the three - dimensional forming fiber panels by the dimensional forming angle. As a result of applying the three dimensional surface shape to the back side of the fiber panel and testing the adhesion strength by the three dimensional forming angle, it was confirmed that the bonding strength of the specimens to which the dimensional molding was applied was higher than that of the non dimensional molding. In addition, the highest adhesion strength was confirmed in a specimen having a three-dimensional forming angle of 70 °.

  • PDF

Safely Improvement Program for High-Rise Office Building Management (고층건물 관리자의 안전관리 개선방안)

  • Lee, Yong-Sam;Choi, Jong-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.87-96
    • /
    • 2005
  • In the construction industry, most safety related researches have been focused on the safety matters in construction job site while the safety issues regarding facility management have been received limited attention. Hence, this research aimed to uncover the problems of current safety management practices then suggest improvement plans. Through the questionnaire suey and analysis, following conclusions were drawn. Regarding the safety mindset, participation rate in safety prevention activities is average at most. Therefore, the extra attention and effort by property owners and managers are required. Examination of accidents indicated that 88% of them were stemmed from unsafe activities, 10% from unstable mentality and 2% from unavoidable natural disasters. Therefore, 90% of these accidents could be prevented by eliminating unsafe activities. In addition to the above findings, several other facts and suggestions are detailed.

An logical Investigation for utilization of BIM in Facility Management Phase (시설물 유지관리 단계에 BIM 활용을 위한 이론적 고찰)

  • Yang, Sung-Hoon;Choi, Won-Sik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1242-1244
    • /
    • 2012
  • 최근 건설 산업의 패러다임으로 부각중인 BIM 기술은 기획 설계 시공 단계를 거쳐 유지관리 단계에서의 활용성을 넓히고 있으며 시설안전공단에서는 총 5만 6,450개 이르는 국내 사회간접자본(SOC)인 시설물 유지관리에 BIM 기술을 도입하기위한 연구를 진행중에 있다. 현재 국내에서는 웹 기반 시설물관리 시스템(FMS : Facility Management System)을 통해 국내 시설물의 기본정보와 점검 및 관리 정보를 서비스 중에 있으나 대상 시설물의 설계도면 및 유지관리 도면, 안전점검 실사 보고서 등이 2D 기반으로 유통되고 있어 BIM 적용을 위한 많은 체계마련이 시급한 실정이다. 이에 본 논문에서는 2D 기반의 시설물 유지관리 체계에 BIM을 활용하기위한 방안을 제안하고자 하였다.

Heat transfer characteristics of redan structure in large-scale test facility STELLA-2

  • Yoon, Jung;Lee, Jewhan;Kim, Hyungmo;Lee, Yong-Bum;Eoh, Jaehyuk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1109-1118
    • /
    • 2021
  • The construction of STELLA-2 facility is on-going to demonstrate the safety system of PGSFR and to provide comprehensive understanding of transient behavior under DBEs. Considering that most events are single-phase natural circulation flow with slow transient, STELLA-2 was designed with reduced-height of 1/5 length scale. The ratio of volume to surface area in the vessel can relatively increase resulting in excessive heat transfer. Therefore, a steady-state thermal-hydraulic analysis was performed and the effect of design change to reduce the heat transfer through redan was investigated. The heat transfer through single wall redan in STELLA-2 was 3% of the core power, comparable to 1% of the core power in PGSFR. By applying the insulated redan, about 70% of decrease effect was observed. The effect on transient behavior was also evaluated. The conclusion of this study was directly applied to the STELLA-2 design and the modified version is under construction.

Critical Criteria Based on Facility Condition Index for Supporting Priority Decision-making in Educational Facilities

  • Shin, Seung Woo;Yi, June Seong
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.687-688
    • /
    • 2015
  • The objective of identifying the cause of inconsistency in determining priority of educational facility maintenance, any related factors were thoroughly identified and tested, to see if it has any effect on decision-making process in resource allocation for educational facilities. On the assumption that 'the more there are to be repaired/maintained and deferred, the higher the relevant cost will be, this will lead to a significant social loss. Accordingly, this study established a framework of determining resource allocation priority based on deferred maintenance and its related expenses. For doing so, it was required to determine relative ranking in terms of resource allocation within a pre-assigned school district, in consideration of the criticality of each deferred maintenance attribute/variable.

  • PDF

Maintenance Priority Determination Method considering the Shape and Property Information of Roads and Pipe Networks (도로, 관망의 형상 및 속성정보를 고려한 유지보수 우선순위 결정 방법)

  • Jang, Young-Hoon;Park, Wonyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.279-280
    • /
    • 2023
  • Due to the deterioration of infrastructure, the importance of maintenance is continuously increasing. Therefore, an integrated maintenance method for various facilities is required. In this study, a maintenance priority determination method for integrated maintenance of roads and pipe network facilities was developed. It is possible to analyze attribute information by using GIS data of roads and pipe networks, and shape information can be used. This information is derived as quantitative figures for determining maintenance priorities. In the future, it is expected that facility maintenance can be further advanced in connection with maintenance method and quantity information for each facility.

  • PDF

THE DEVELOPMENT OF BUILDING MAINTENANCE SYSTEM FOR DETERMINING PRIORITIES OF PUBLIC FACILITY REPAIRS & REPLACEMENT (I)

  • Chun-Kyong Lee;Tae-Gab Jung;Byong-Jin Yu;Tae-Keun Park
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.376-381
    • /
    • 2011
  • In Korea Water Resources Corporation (K-Water) has seen four problems rising in four aspects of property management of approximately 1,300 buildings scattered through put to country. To solve these, ground data for repair and replacement works to be conducted for prevention will be prepared and building maintenance system (hereinafter referred to as PBMS) intended to record related repair and replacement work histories and calculate LCC of the related these items will be developed. PBMS, a web-based system, will be developed for users' convenience and data monitoring in real time. To sum up, PBMS are expected to maximize efficiency in four aspects including the establishment of repair and replacement work plans for prevention, history management, DB for predicting future work to be occurred and enable the determination of priorities by being developing into facility condition assessment systems through the results of analysis of repair and replacement histories and LCC.

  • PDF

A Study on the Implementation of the Safety Management Plan in the Construction Technology Promotion Act (건설기술진흥법 안전관리계획서의 실행방안에 관한 연구)

  • Shin, Sung-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.104-105
    • /
    • 2018
  • The purpose of the safety management plan under the Construction Technology Promotion Act is to improve the quality and safety of construction engineers during construction work. To prevent a collapse accident of a facility after completion by preventing a collapse accident of gravel, an earthwork, a river structure or the like. In order to prevent collapses, the purpose of the project is to study measures to improve the ability of construction technology promotion law to ensure the quality of construction materials at the time of construction work.

  • PDF

THE MODULES ADVENCEMENT TO DEVELOP PMIS INTO FMS IN THE CASES OF MEDICAL FACILITIES

  • Jong-Soon Park;Byeong-Gi Yoo;Kyung-Mi Hyun
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1328-1333
    • /
    • 2009
  • On the construction area, Information Technology (IT) has been a considerably significant part over the all phases; plan, design, procurement, construction and post-construction. For example, CALS, CITIC, PMIS, FMS, BIM and etc, designed and applied for managing construction industry are already valuable to improve on the Construction Management (CM). To develop these management methods, lots of mixed-systems are studied and progressed so far. In this paper, more useful and efficient system modules are proposed through investigating PMIS cases implemented, especially medical projects, to improve into FMS on the post-construction. Because most PMIS on the construction phase is used not to continue as FMS, considerable cost and time is consumed to rebuild the system, even both systems have common modules. As these wastes are faced to design systems, the important modules on PMIS are derived and analyzed to apply to FMS to save time and cost on CM.

  • PDF

Proposal of Localization Policy Based on the Status of Chinese's Research Facilities and Equipment Construction in Korean Basic and Analytical Science Field (국내 기초·분석과학 분야 내 중국산 연구시설·장비 구축 현황에 따른 국산화 정책 제언)

  • Kim, Chang-Yong;Chung, Taewon;Kong, Jaehyun;Park, Chan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.460-471
    • /
    • 2019
  • The aim of this study was to examine the scale and market share of Chinese's research facility & equipment in the domestic research equipment market of basic and analytical science field for analyzing the difference of the number and amount of construction by year of acquisition, national research facility equipment standard classification code, and type of institution based on the information of the research equipment invested by the Korean government for the past 14 years. In addition, we analyzed the correlation among the year of acquisition, equipment standard classification code, and type of institution variables. As of January 1 2019, from 2005 to 2018, 50 Chinese's research facilities & equipments (main equipment with a construction cost of 30 million won or more) built in the basic and analytical science fields were selected for this study and their number of construction, amount of construction, year of acquisition, type of institution, and standard classification code were analyzed. Differences of the number and amount of construction with-in and by year of acquisition, standard classification code, and type of institution were tested using a single sample Chi-square test, Mann-Whitney U test, and Kruskal-wallis test. The correlation among the three variables was analyzed by using the Chi-square test of cross-tabulation analysis. And there was a statistically significant correlation among the year of acquisition, standard classification code, and type of institution (p<.05). Compared to the 2000s, in the 2010s, high-priced Optical Electronics/Video Equipment was installed at private universities, private enterprises, and government-affiliated research institute. Therefore, the domestic construction status of Chinese's research facility & equipment in the basic science and analytical science field is less than that of the domestic ones, but the number and the amount of construction are increasing statistically. So it is necessary for the government to be able to recognize the possibility that the Chinese's research facility and equipment can encroach on the domestic research industry market and to prepare related provision.