• Title/Summary/Keyword: Coincidence Frequency

Search Result 55, Processing Time 0.021 seconds

Characteristics of Coupled Acoustic Wave Propagation in Metal Pipe (금속 배관의 연성된 음향 전파 특성)

  • Kim, Ho-Wuk;Kim, Min-Soo;Lee, Sang-Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.3
    • /
    • pp.267-273
    • /
    • 2008
  • The circular cylinder pipes are used in the many industrial areas. In this paper, the acoustic wave propagation in the pipe containing a gas is researched. First of all, the theory for the coupled acoustic wave propagation in a pipe is investigated. Acoustic wave propagation in pipe can not be occurred independently between the wave of the fluid and the shell. It requires complicated analysis. However, as a special case, the coupled wave in a high density pipe containing a light density medium is corresponded closely to the uncoupled in-vacuo shell waves and to the rigid-walled duct fluid waves. The coincidence frequencies of acoustic and shell modes contribute to the predominant energy transmission. The coincidence frequency means the frequency corresponding to the coincidence of the wavenumber in both acoustic and shell. In this paper, it is assumed that the internal medium is much lighter than the pipe shell. After the uncoupled acoustic wave in the internal medium and uncoupled shell wave are considered, the coincidence frequencies are found. The analysis is successfully confirmed by the verification of the experiment using the real long steel pipe. This work verifies that the coupled wave characteristic of the shell and the fluid is occurred as predominant energy transmission at the coincidence frequencies.

Low-noise fast-response readout circuit to improve coincidence time resolution

  • Jiwoong Jung;Yong Choi;Seunghun Back;Jin Ho Jung;Sangwon Lee;Yeonkyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1532-1537
    • /
    • 2024
  • Time-of-flight (TOF) PET detectors with fast-rise-time scintillators and fast-single photon time resolution silicon photomultiplier (SiPM) have been developed to improve the coincidence timing resolution (CTR) to sub-100 ps. The CTR can be further improved with an optimal bandwidth and minimized electronic noise in the readout circuit and this helps reduce the distortion of the fast signals generated from the TOF-PET detector. The purpose of this study was to develop an ultra-high frequency and fully-differential (UF-FD) readout circuit that minimizes distortion in the fast signals produced using TOF-PET detectors, and suppresses the impact of the electronic noise generated from the detector and front-end readout circuits. The proposed UF-FD readout circuit is composed of two differential amplifiers (time) and a current feedback operational amplifier (energy). The ultra-high frequency differential (7 GHz) amplifiers can reduce the common ground noise in the fully-differential mode and minimize the distortion in the fast signal. The CTR and energy resolution were measured to evaluate the performance of the UF-FD readout circuit. These results were compared with those obtained from a high-frequency and single ended readout circuit. The experiment results indicated that the UF-FD readout circuit proposed in this study could substantially improve the best achievable CTR of TOF-PET detectors.

The reconstruction of Structure Velocity Field Using Nearfield Acoustic Holography (근접음장 음향 홀로그래피를 이용한 평판내의 속도분포 예측)

  • 권오훈;이효근;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.251-259
    • /
    • 1994
  • Nearfield acoustic holography is known as a powerful tool to study sound radiation from a structure. In this work, the so called backward propagation of sound pressure field is studied to obtain the structure velocity distribution. The results, which were obtained using FFT algorithms, are presented for a finite plate excited at the frequencies above and below coincidence. These results illustrate the effect of stand-off distance and noise. An optimum cutoff frequency in wavenumber domain was suggested to reduce the effects of evanescent wave in the backward propagation. The experimental results were also included for a plate to demonstrate the effectiveness of the suggested cutoff frequency. The optimum cutoff frequency to exclude the unwanted noise in the process of reconstruction of the velocity field gives the good results in both simulations and experiments.

Short and Efficient Frequency Hopping Codes (짧고 효과적인 주파수 도약 수열 생성)

  • Kim Young-Joon;Kim Dae-Son;Song Hong-Yeop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.4C
    • /
    • pp.318-323
    • /
    • 2006
  • In this paper we propose three methods to generate short hopping sequences for the frequency hopping system. First, we explain the one coincidence set of sequences and the polyphase power residue seqences which have been known previously, and we suggest a method by modifying the one coincidence sequence and two methods by using the power residue sequences. We verify that the optimal position deleted-power residue sequences have the best Hamming autocorrelation property and the first position deleted-power residue sequences and the modified one coincidence sequences follows with respect to Hamming autocorrelation. We also explain that these sequences have the good balance property and can be implemented with low complexity.

Sound Insulation Performance of the Panel Structures in High Speed Train: Transmission Loss of the Corrugated and Extruded Panels (고속철도 차음구조의 차음성능: 주름 및 압출재의 투과손실)

  • Kim, Seock-Hyun;Paek, In-Su;Kim, Jeong-Tae
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.82-89
    • /
    • 2007
  • Sound transmission characteristics are investigated on the corrugated steel and aluminium extruded panels used for railway vehicles. Sewell-Sharp-Cremer(SSC) model, equivalent orthotropic plate model and equivalent mass law are applied to predict the sound transmission loss. The predicted values of the sound transmission loss are compared with the measured values. The reliability and the limitation of the prediction models are investigated. For the corrugated panels and honeycomb panels, the coincidence and local resonance severely deteriorate the sound insulation performance around the corresponding frequency bands. The result of the study shows that the equivalent orthotropic plate model and the SSC model can be used as good prediction models, if the coincidence frequency or local resonance frequency is correctly applied.

  • PDF

Coincidence Analysis of Keywords of the Journal of Korean Academy of Nursing with MeSH (대한간호학회지 게재 논문 주요어 분석(2003-2005년))

  • Jeong Geum-Hee;Ahn Young-Mee;Cho Dong-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.7
    • /
    • pp.1420-1425
    • /
    • 2005
  • Purpose: We try to disclose how much the keywords of the papers from the Journal of the Korean Academy of Nursing coincide with MeSH terminologies and to understand the major subjects of the recent nursing research in Korea from keywords. Methods: Keywords of journals were extracted and compared with MeSH terms. The frequency of the appearance of each keyword was sorted by a descending order. Results: Coincidence rate of 1,235 keywords with MeSH terms was $51.6\%$. Out of them, depression, elderly, stress, self efficacy, quality of life, exercise, middle-aged women, and women appeared most frequently in descending order. Conclusion: Coincidence rate of the keywords with MeSH terms was at an acceptable level, however to improve it, the education of submitters and editorial board members are required, as well as the copy editor, to take a role in checking keywords. To infer the subjects of the research from keywords might well represent the recent topics of research work.

The fourth-order interference between entangled state photon pairs with different frequencies (진동수가 서로 다른 얽힘상태 광자쌍의 4차 간섭)

  • Kim, Heon-Oh;Ko, Jeong-Hoon;Kim, Tae-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.308-313
    • /
    • 2002
  • One of the nonclassical effects in two-photon interference experiments, spatial quantum beating, is observed in fourth-order interference with pairs of photons produced by a spontaneous parametric down-conversion process. When photon pairs in different frequencies $\omega1$ and $\omega2$ are mixed together, and directed to two detectors, the coincidence counts exhibit a cosine modulation with difference frequency | $\omega1$- $\omega2$|. The measured coincidence counts turned out to have an interference pattern with periodicity of 10.45 ㎛ in position or 34.82fs in time delay, which corresponds to the period 2$\pi$/| $\omega1$- $\omega2$| for the beat frequency of 0.29${\times}10^{14}$Hz.

Interference experiment using entangled photons with wavelengths of 640 nm and 660 nm (파장 640 nm와 660 nm 광자쌍의 간섭)

  • Kim Heonoh;Shin Harim;Kim Wonsik;Kwon Osung;Kim Taesoo
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.399-404
    • /
    • 2004
  • We present a quantum interference experiment with frequency-entangled pairs of photons with wavelength of 640 nm and 660 nm produced in the process of parametric down-conversion. When photon pairs in different angular frequencies $\omega$$_1$and $\omega$$_2$are registered by two detectors the coincidence counts exhibits a two-photon fringe as a function of relative time delay $\delta$$\tau$ of two photons within the coherence time depending on the arrangement of the detector pairs.

The accuracy of the frequency dependent type apex locator (주파수의존형 전자근관장측정기의 정확도에 관한 연구)

  • Park, Ju-Huun;Roh, Byoung-Duck;Lee, Seoung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.150-160
    • /
    • 1996
  • The present study was to evaluate the accuracy of the frequency dependent type apex locator, Root-ZX. The subjects included 505 root canals of 238 teeth treated by the Department of Conservative Dentistry, and 22 human premolars which were schduled to be extracted for the orthodontic reasons. The results were as follows ; 1. The working lengths determined by Root-ZX were compared with radiographic readings. Of the total 505 root canals, 66 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.13mm{\pm}1.05$ longer than those of radiographic readings. 2. The length difference between the file tip determined by Root-ZX and the apical constriction in extracted teeth were measured. Of the total 24 root canals, 70.8 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.12mm{\pm}0.50$beyond the apical constriction. 3. The vitality of the teeth did not show any statistical difference(p>0.05) in the accuracy of the Root-ZX readings. The presence of the periapical lesions, however, significantly lowered the percentage of ${\pm}0.5mm$ accuracy in Root-ZX measurements.(p<0.05). In the presence of periapical lesions, the percentage within ${\pm}0.5mm$ was significantly lower.

  • PDF

Quantum Interference Experiments with Frequency Entangled Photon Pairs at 1.5 ㎛ Telecommunication Band (1.5 ㎛ 통신파장대역 진동수 얽힘 광자쌍의 양자간섭)

  • Kim, Heon-Oh;Kim, Yong-Soo;Youn, Chun-Ju;Cho, Seok-Beom
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.6
    • /
    • pp.276-282
    • /
    • 2011
  • We performed experiments on Hong-Ou-Mandel type two-photon interference with frequency entangled photon pairs at 1.5 ${\mu}m$ telecommunication band generated through femtosecond pulsed spontaneous parametric down-conversion. Two different angular frequencies ${\omega}_1$ and ${\omega}_2$ were selected using CWDM(coarse wavelength division multiplexing) filters at the output ports of the interferometer. The coincidence counting rates were measured with varying path-length difference between the two interferometer arms to observe the two-photon interference patterns of spatial beating. The obtained visibilities in the net coincidence were close to the theoretical limit of 100%.