• Title/Summary/Keyword: Characteristic design parameters

Search Result 608, Processing Time 0.029 seconds

Design of Robust Expected Loss Control Chart (로버스트 기대손실 관리도의 설계)

  • Lee, Hyeung-Jun;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.10-17
    • /
    • 2016
  • Control Chart is a graph which dots the characteristic values of a process. It is the tool of statistical technique to keep a process in controlled condition. It is also used for investigating the state of a process. Therefore many companies have used Control Chart as the tool of statistical process control (SPC). Products from a production process represent accidental dispersion values around a certain reference value. Fluctuations cause of quality dispersion is classified as a chance cause and a assignable cause. Chance cause refers unmanageable practical cause such as operator proficiency differences, differences in work environment, etc. Assignable cause refers manageable cause which is possible to take actions to remove such as operator inattention, error of production equipment, etc. Traditionally ${\bar{x}}-R$ control chart or ${\bar{x}}-s$ control chart is used to find and remove the error cause. Traditional control chart is to determine whether the measured data are in control or not, and lets us to take action. On the other hand, RNELCC (Reflected Normal Expected Loss Control Chart) is a control chart which, even in controlled state, indicates the information of economic loss if a product is in inconsistent state with process target value. However, contaminated process can cause control line sensitive and cause problems with the detection capabilities of chart. Many studies on robust estimation using trimmed parameters have been conducted. We suggest robust RNELCC which used the idea of trimmed parameters with RNEL control chart. And we demonstrate effectiveness of new control chart by comparing with ARL value among traditional control chart, RNELCC and robust RNELCC.

A Study on characteristic of a double resonant type high frequency inverter using Phase-Shift (Phase-Shift를 이용한 복공진형 고주파 인버터의 특성에 관한 연구)

  • 조규판;김종해;남승식;김동희;노채균;배영호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.109-117
    • /
    • 2000
  • A full bridge type double resonant high frequency resonant inverter to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one and this paper also realize the output control of independence irrespective of the switching frequency using Phase-shift. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters, such as switching frequency, the variation of phase angle ($\phi$) of Phase-shift.

  • PDF

Model Analysis of Plate using by Digital Test System (디지털 실험장치를 이용한 판의 모우드 해석)

  • Hong, Bong-Ki;Bae, Dong-Myung;Bae, Seong-Yoeng
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.1
    • /
    • pp.39-55
    • /
    • 1993
  • Modal Analysis is the process of characterizing the dynamic properties of an elastic structure by identifying its modes of vibration. A mode of vibration is a global property of an elastic structure. That is, a mode has a specific natural frequency and damping factor which can be identified from response data at practically any point on a structure, and it has a characteristic mode shape which identifies the mode spatially over the entire structure. Modal testing is able to be performed on structural and mechanical structure in an effort to learn more about their elastic behavior. Once the dynamic properties of a structure are known its behavior can be predicted and therefore controlled or corrected. Resonant frequencies, damping factors and mode shape data can be used directly by a mechanical designer to pin point weak spots in a structure design, or this data can also be used to confirm or synthesize equations of motion for the elastic structure. These differential equations can be used to simulate structural response to know input forces and to examine the effects of pertubations in the distributed mass, stiffness and damping properties of the structure in more detail. In this paper the measurement of transfer functions in digital form, and the application of digital parameter identification techniques to identify modal parameters from the measured transfer function data are discussed. It is first shown that the transfer matrix, which is a complete dynamic model of an elastic plate structure can be written in terms of the structural modes of vibration. This special mathematical form allows one to identify the complete dynamics of the structure from a much reduced set of test data, and is the essence of the modal approach to identifying the dynamics of a structure. Finally, the application of transfer function models and identification techniques for obtaining modal parameters from the transfer function data are discussed. Characteristics on vibration response of elastic plate structure obtained from the dynamic analysis by Finite Element Method are compared with results of modal analysis.

  • PDF

The Effect of Open Ratio of the Inlet Baffle on Hydraulic Behavior within a Rectangular Sedimentation Basin (장방형 침전지 유입 정류벽 유공비의 지내 수리거동에 미치는 영향 연구)

  • Park, No-Suk;Kim, Seong-Su;Lim, Sung-Eun;Lee, Doo-Jin;Seo, In-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.345-352
    • /
    • 2009
  • The purpose of inlet baffle is to distribute the flow uniformly over the entire cross-sectional area of the sedimentation basin. The goal when designing this baffle is to achieve some head loss while keeping the velocity gradients through the ports equal to the velocity gradient in the end of the flocculator, so as to not break up the flocs. Sedimentation tank performance is strongly influenced by hydrodynamic and physical effects such as inlet design. This study was conducted to evaluate the effect of open ratio of the inlet baffle on hydraulic behavior within a rectangular sedimentation basin using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 18 points in the full-scale sedimentation basin at Y water treatment plant. Good agreement was obtained between the CFD predictions and the experimentally measured data. From the simulation results of the existing basin with 7.4 % open ratio, it was investigated that extreme decrease in velocity occurred in the middle of basin. Since then, flow features was unstable. The region which the velocity decrease rapidly moved forward to the flow direction in proportion to the increase of inflow velocity. Also, it was investigated that the flow characteristic of 6.0 % open ratio was significantly different from 7.4 % open ratio at the same configuration condition. These results are a clear indication that inflow momentum and open ratio are the parameters affecting the characteristics of hydraulic patterns. The influence of these parameters on the sedimentation performance requires further study.

A Study on the High Frequency Resonant Inverter using ZVS suitable for IH-Jar (IH-Jar에 적합한 ZVS를 이용한 고주파 공진 인버터에 관한 연구)

  • Park, Dong-Han;Lee, Jong-Hyeon;Oh, Ji-Yong;Kim, Gu-Yong;Kim, Hae-Jun;Won, Jae-Sun;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.870-873
    • /
    • 2018
  • This paper presents the high frequency resonant inverter using ZVS(Zero Voltage Switching) known as the soft switching technology, which can reduce the turn-on and turn-off switching losses. Also, the analysis of the proposed resonant inverter is described by adopting normalized parameters, and its operating characteristics are evaluated according to the switching frequency and parameters. An example of 1.3[kW] IH-Jar design technique is presented based on the characteristic values obtained from the theoretical analysis. To prove the validity of the theoretical analysis, the experimental results using IGBT as the switching devices are additionally presented. In the future, it can be practically used in various power systems such as induction heating cooking, IH-Jar etc.

Characteristics of the In-cylinder Flow and Fuel Behavior with Respect to Engine Temperature Condition in the MPI Dual Injection Engine (MPI Dual Injection 엔진의 온도 조건 변화에 따른 엔진 내부 유동 및 연료 거동 특성에 관한 연구)

  • Lee, Seung Yeob;Chung, Jin Taek;Park, Young Joon;Yu, Chul Ho;Kim, Woo Tae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.210-219
    • /
    • 2014
  • The MPI dual injection engine can enhance the fuel efficiency and engine power. By using one injector per one intake port, MPI dual injection engine has an excellent fuel atomization and targeting injection. As the basic research for the MPI Dual injection engine design, this research was investigated in order to understand the characteristic of the in-cylinder flow and fuel behavior according to engine temperature condition and the fuel type in the MPI dual injection engines. The 3D unsteady CFD simulation for the MPI Dual injection engine was performed using STAR-CD. The engine operating condition was 2,000 rpm/WOT. The parameters for this study were fuel types, fuel temperatures and wall temperatures. As a result, the intake air amount, evaporated fuel in the cylinder and the fuel film on the wall were presented according to parameters that depend on the fuel properties and engine wall temperature. Also, the results were influenced by in-cylinder flow such as the intake flow, back flow and so on.

Resistance Performance of Korean Small Coastal Fishing Boat in Low-Speed Range (한국 저속 소형 연안어선의 저항성능)

  • Jee, Hyun-Woo;Lee, Young-Gill;Kang, Dae-Sun;Ha, Yoon-Jin;Choi, Young-Chan;Yu, Jin-Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.1
    • /
    • pp.10-23
    • /
    • 2009
  • Korean small coastal fishing boats have the different kind of fisheries and customs against Japanese fishing boats. Those bring some influences on the principal parameters of hull form. In same displacement, Korean small coastal fishing boat has generally shorter length, draft and wider breadth than Japanese fishing boat. Furthermore, even though the parameters of each hull form are similar, it is known that the resistance performance of Korean small coastal fishing boat is worse than that of Japanese fishing boat. In this study, the representative hull forms of Korean and Japanese small coastal fishing boats are selected and compared to evaluate the resistance performance of Korean fishing boat in low-speed range. The hull form of the Korean fishing boat is modified as comparison with that of the Japanese fishing boat to confirm the partial characteristic differences between the hull forms and the resistance performances. The representative partial characteristics of hull form are the gradient of chine line, keel shape and stern length. The resistance performances of the modified hull forms are evaluated by INHAWAVE which is one of CFD program and model tests in towing tank. The results of the present study will be used to improve the resistance performance and to develop the practical hull form of Korean small coastal fishing boats as principal data in the preliminary hull form design of fishing boats.

The solar cell modeling using Lambert W-function (Lambert W 함수를 이용한 태양전지 모델링)

  • Bae, Jong-Guk;Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.278-281
    • /
    • 2011
  • This system can predict the maximum output about all illumination levels so that the PV system designer can design the system having the best efficiency. For the output prediction exact about the solar cell, that is the device the basis most in the PV system, the basis has to be in order to try this way. The solution based on Lambert W-function are presented to express the transcendental current-voltage characteristic containing parasitic power consuming parameters like series and shunt resistances. A simple and efficient method for the extraction of a single current-voltage (I-V) curve under the constant illumination level is proposed. With the help of the Lambert W function, the explicit analytic expression for I is obtained. And the explicit analytic expression for V is obtained. This analytic expression is directly used to fit the experimental data and extract the device parameters. The I-V curve of the solar cell was expressed through the modeling using Lambert W-function and the numerical formula where there is the difficulty could be logarithmically expressed This method expresses with the I-V curve through the modeling using Lambert W-function which adds other loss ingredients to the equation2 as to the research afterward. And the solar cell goes as small and this I-V curve can predict the power penalty in the system unit.

  • PDF

A Study on the High Frequency Resonant Inverter of Class D SEPP type using LS-ZVS-LSTC (LS-ZVS-LSTC를 이용한 D급 SEPP형 고주파 공진 인버터에 관한 연구)

  • Park, Dong-Han;Choi, Byeong-Joo;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.260-268
    • /
    • 2020
  • This paper presents the high frequency resonant inverter of class D SEPP(Single-Ended Push Pull) type using LS-ZVS-LSTC, which can reduce the switching losses during the turn-on and turn-off switching time. The analysis of high frequency resonant inverter using LS-ZVS-LSTC(Low-loss Turn-off Snubber Capacitor) proposed in this paper is described in general by adopting the normalized parameters. The operating characteristics of the proposed high frequency resonant inverter were also evaluated by using the control parameters such as the normalized control frequency(μ), the normalized load time constant(τ), the coupling factor(κ) and so on. Based on the characteristic values through the characteristics of evaluation, an example of the design method of the 1.8[kW] class D SEPP type high frequency inverter is suggested, and the validity of the theoretical analysis is verified using the experimental data.

The Degradation Analysis of Characteristic Parameters by NBTI stress in p-MOS Transistor for High Speed (고속용 p-MOS 트랜지스터에서 NBTI 스트레스에 의한 특성 인자의 열화 분석)

  • Lee, Yong-Jae;Lee, Jong-Hyung;Han, Dae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1A
    • /
    • pp.80-86
    • /
    • 2010
  • This work has been measured and analyzed the device degradation of NBTI (Negative Bias Temperature Instability) stress induced the increase of gate-induced-drain-leakage(GIDL) current for p-MOS transistors of gate channel length 0.13 [${\mu}m$]. From the relation between the variation of threshold voltage and subthreshold slop by NBTI stress, it has been found that the dominant mechanism for device degradation is the interface state generation. From the GIDL measurement results, we confined that the EHP generation in interface state due to NBTI stress led to the increase of GIDL current. As a results, one should take care of the increased GIDL current after NBTI stress in the ultra-thin gate oxide device. Also, the simultaneous consideration of reliability characteristics and dc device performance is highly necessary in the stress parameters of nanoscale CMOS communication circuit design.