• Title/Summary/Keyword: Center Loss

Search Result 3,753, Processing Time 0.037 seconds

Status of 3 MW PM Synchronous Generator Development Project for Off-shore WECS (3MW 해상풍력용 영구자석 동기발전기 개발현황)

  • Kim, Dong-Eon;Han, Hong-Sik;Lee, Hong-Gi;Jung, Yung-Gyu;Suh, Hyung-Suck;Chung, Chin-Wha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.423-426
    • /
    • 2007
  • Pohang Wind Energy Research Center (PoWER-C) is developing a 3 MW Radial Flux Permanent Magnet (RFPM) Synchronous Generator for offshore Wind Energy Converter (WEC). The rotor rpm is 15.7 and the gear ratio is set to be 92.93. The nominal generator rpm at the rated load is about 1459. To reduce the switching loss in the power electronics, the maximum frequency is limited to 100 Hz. This requirement limits the number of pole to six or eight. Permanent magnet excitation is assumed for higher energy yield and higher efficiency. In this report, the requirements and the first efforts for the physics design are described.

  • PDF

Characteristics of Fluid Flow and Heat Transfer in a Fluidized Heat Exchanger with Circulating Solid Particles

  • Ahn, Soo-Whan;Lee, Byung-Chang;Kim, Won-Cheol;Bae, Myung-Whan;Lee, Yoon-Pyo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1175-1182
    • /
    • 2002
  • The commercial viability of heat exchanger is mainly dependent on its long-term fouling characteristic because the fouling increases the pressure loss and degrades the thermal performance of a heat exchanger. An experimental study was performed to investigate the characteristics of fluid flow and heat transfer in a fluidized bed heat exchanger with circulating various solid particles. The present work showed that the higher densities of particles had higher drag force coefficients, and the increases in heat transfer were in the order of sand, copper, steel, aluminum, and glass below Reynolds number of 5,000.

Telomere Erosion-Induced Mitotic Catastrophe in Chinese Hamster Don Cells

  • Sohn, Sea H.;Multani, Asha S.;Gugnani, Pankaj K.;Pathak, Sen
    • Proceedings of the KSAR Conference
    • /
    • 2002.06a
    • /
    • pp.15-15
    • /
    • 2002
  • Telomere erosion is the earliest chromatin modification in cells entering the apoptotic regime. The purpose of this investigation was to demonstrate that loss of telomeric DNA was involved in the induction of mitotic catastrophe and cell death of Chinese hamster Don cells that were grown continuously without subculturing for several days. Don, which is a diploid male Chinese hamster-derived cell line, was grown without sub-culturing for one to four days at 37℃ and then harvested for cytological preparations. (omitted)

  • PDF

Ground vibrations due to underground trains considering soil-tunnel interaction

  • Yang, Y.B.;Hung, H.H.;Hsu, L.C.
    • Interaction and multiscale mechanics
    • /
    • v.1 no.1
    • /
    • pp.157-175
    • /
    • 2008
  • A brief review of the research works on ground vibrations caused by trains moving in underground tunnels is first given. Then, the finite/infinite element approach for simulating the soil-tunnel interaction system with semi-infinite domain is summarized. The tunnel is assumed to be embedded in a homogeneous half-space or stratified soil medium. The train moving underground is modeled as an infinite harmonic line load. Factors considered in the parametric studies include the soil stratum depth, damping ratio and shear modulus of the soil with or without tunnel, and the thickness of the tunnel lining. As far as ground vibration is concerned, the existence of a concrete tunnel may somewhat compensate for the loss due to excavation of the tunnel. For a soil stratum resting on a bedrock, the resonance peak and frequency of the ground vibrations caused by the underground load can be rather accurately predicted by ignoring the existence of the tunnel. Other important findings drawn from the parametric studies are given in the conclusion.

Measurement of Temperature in Double-concentric Diffusion Flames by Rapid Insertion Technique (급속 삽입범에 의한 동축 이중 확산화염 내부 온도 분포의 측정)

  • Chung, J.R.;Nam, P.W.;Lee, G.W.;Jurng, J.S.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.231-240
    • /
    • 1999
  • The temperature distribution in double-concentric diffusion flames have been investigated experimentally by rapid insertion technique. Using a fine thermocouple and rapid insertion mechanism, the temperature has been measured before soot particles attach the thermocouple junction which can affect the temperature signal by changing the radiation heat loss. For double-concentric diffusion flames, the temperature at the axis is higher than that of normal coflow diffusion flames because of the inverse diffusion flame at the center of the flame. However, it is almost same at the periphery on which the inverse flame does not have an effect.

  • PDF

Experimental Study on Behavior near Extinction in Buoyancy-minimized Counterflow Diffusion Flame (부력 효과의 최소화를 통한 소화 근처 대향류 확산화염 거동에 관한 실험적 연구)

  • Chung, Yong Ho;Park, Jeong;Kwon, Oh Boong;Yun, Jin-Han;Keel, Sang-In;Kim, Tae Hyung;Kim, Young Ju
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.23-26
    • /
    • 2012
  • Experimental study was conducted to elucidate flame extinction phenomena in counterflow flame. Using a curtain helium flow significantly reduced buoyancy such that the flame can be positioned at the center between the upper and lower nozzles even at the velocity ratio of 1.0. The curves of critical diluent mole fraction versus global strain rate have C-shapes. The flame oscillation was observed prior to low strain rate flame extinction at both flame conditions with and without minimizing buoyancy force. The results show that, at low strain rate flame, the self-excitation frequency with the order of 1.0 Hz in the case of utilizing pure helium gradually decreases in increase of $N_2$ mole fraction in the curtain flow, meaning that buoyancy suppresses the self-excitation of the outer edge flame.

  • PDF

The Standard of test and evaluation for HTS cable system (고온 초전도 케이블 시스템 시험 및 평가 기준(안))

  • Choi, Hyung-Sik;Hwang, Si-Dole;Sohn, Song-Ho;Lim, Ji-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.490-491
    • /
    • 2006
  • Based on the real field test of 22.9kV HTS cable, which is installed in Gochang Power Testing Center located in Chonbuk Province, the standard for the performance test and the quality evaluation have been established. This work will be applied to the development of HTS cable and the purchase process as a practical material. In particular, new items for the cable evaluation such as the measurement of critical current and the heat loss, which was not dealt with in conventional cable, are specified in detail.

  • PDF

Statistical Analysis of Main Factors With Affecting the Physical Properties of Rubber Compounds (고무조성물의 물리적 성질에 영향을 미치는 주요인자에 대한 통계학적 해석)

  • Lee, Seag;Park, Nam-Cook
    • Elastomers and Composites
    • /
    • v.32 no.1
    • /
    • pp.20-28
    • /
    • 1997
  • This study have Investigated the effect of various factors related to the physical properties of vulcanizated rubber compounds. rubber type, carbon black type and carbon black loading were selected as main factors and evaluation were tested by tables of orthogonal arrays with 3 factors and 3 levels. rubber types have affected cure time, tensile strength, and $T_g$ as main factor and carbon black loading have affected viscosity, scorch time, maximum torque, hardness, 300% modulus, rebound, heat build-up, $0\;&\;60^{\circ}C$ tangent delta, PICO and CUT/CHIP loss as main factor but the effects of carbon black type have affected only bound rubber content.

  • PDF

Equine Polysaccharide Storage Myopathy in an American Paint Horse (American Paint Horse에서의 다당류저장성근질환)

  • Yong, Hwan-Yul;Kim, Dae-Young
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.469-471
    • /
    • 2006
  • A 4-year-old, American Paint horse gelding with recurrent episodes of exertional rhabdomyolysis was diagnosed with equine polysaccharide storage myopathy (EPSSM). The common clinical signs were muscle weakness, loss of muscle mass, exercise intolerance, difficulty holding up limbs for farrier, sensitivity of grooming, cramping with reluctance to move and the inability to rise. Through histological examination of skeletal muscle specimens, this case was confirmed of EPSSM.

Effects of Formaldehyde to Urea Mole Ratio on Thermomechanical Curing of Urea-Formaldehyde Resin Adhesives

  • Park, Byung-Dae;Kim, Jae-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.76-86
    • /
    • 2007
  • This study was conducted to investigate the effects of formaldehyde to urea (F/U) mole ratio on thermomechanical curing of UF resin adhesives with different F/U mole ratios. Thermomechanical curing of these UF resin adhesives was characterized using parameters of dynamic mechanical analysis (DMA) such as the gel temperature, maximum storage modulus, and peak temperatures of storage and loss modulus. As the F/U mole ratio decreased, the gel temperature of UF resin adhesives increased. The maximum storage modulus as an indicator of the rigidity of UF resin adhesives decreased with decreasing F/U mole ratio. The peak temperature of tan $\delta$ increased with decreasing F/U mole ratio, indicating that the vitrification occurred faster for high F/U mole ratio of UF resin adhesives than for the one of lower F/U mole ratio. These results partially explained the reason why UF resin adhesives with lower F/U mole ratio resulted in relatively poor adhesion performance when they were applied.