한국연소학회:학술대회논문집
- 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
- /
- Pages.231-240
- /
- 1999
급속 삽입범에 의한 동축 이중 확산화염 내부 온도 분포의 측정
Measurement of Temperature in Double-concentric Diffusion Flames by Rapid Insertion Technique
- 발행 : 1999.10.22
초록
The temperature distribution in double-concentric diffusion flames have been investigated experimentally by rapid insertion technique. Using a fine thermocouple and rapid insertion mechanism, the temperature has been measured before soot particles attach the thermocouple junction which can affect the temperature signal by changing the radiation heat loss. For double-concentric diffusion flames, the temperature at the axis is higher than that of normal coflow diffusion flames because of the inverse diffusion flame at the center of the flame. However, it is almost same at the periphery on which the inverse flame does not have an effect.
키워드