Evaluation of Adult Lung CT Image for Ultra-Low-Dose CT Using Deep Learning Based Reconstruction

  • JO, Jun-Ho;MIN, Hyo-June;JEON, Kwang-Ho;KIM, Yu-Jin;LEE, Sang-Hyeok;KIM, Mi-Sung;JEON, Pil-Hyun;KIM, Daehong;BAEK, Cheol-Ha;LEE, Hakjae
    • 한국인공지능학회지
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2021
  • Although CT has an advantage in describing the three-dimensional anatomical structure of the human body, it also has a disadvantage in that high doses are exposed to the patient. Recently, a deep learning-based image reconstruction method has been used to reduce patient dose. The purpose of this study is to analyze the dose reduction and image quality improvement of deep learning-based reconstruction (DLR) on the adult's chest CT examination. Adult lung phantom was used for image acquisition and analysis. Lung phantom was scanned at ultra-low-dose (ULD), low-dose (LD), and standard dose (SD) modes, and images were reconstructed using FBP (Filtered back projection), IR (Iterative reconstruction), DLR (Deep learning reconstruction) algorithms. Image quality variations with respect to varying imaging doses were evaluated using noise and SNR. At ULD mode, the noise of the DLR image was reduced by 62.42% compared to the FBP image, and at SD mode, the SNR of the DLR image was increased by 159.60% compared to the SNR of the FBP image. Based on this study, it is anticipated that the DLR will not only substantially reduce the chest CT dose but also drastic improvement of the image quality.

관자뼈 HRCT 스캔 시 선량감소 방법에 관한 연구 (A Study on the Dose Reduction Method for Temporal Bone HRCT Scan)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1041-1047
    • /
    • 2023
  • 고 해상력 CT에 해당하는 관자뼈 CT는 높은 관전압과 얇은 단면두께 등의 적용으로 스캔 선량이 인접 부위 검사보다 높다. 이에 검사조건 중 재구성 알고리즘을 변화 적용하여 검사 선량을 줄이면서 병변에 대한 민감도가 우수한 알고리즘을 찾아 유의성과 임상 기초자료 제공 가능성을 알아보았다. 그 결과 100 kVp로 관전압을 낮추어 적용 시 선량이 약 35.6% 감소하였고, 100 kVp로 획득한 Raw data에 Definition 알고리즘 적용 시 SNR, CNR이 우수하였으며 다른 알고리즘과 비교 시 통계적으로 유의한 차이를 보였다(p<0.05). 그리고 구조적 유사도를 비교한 결과 SSIM index가 ROI 별 0.776, 0.813, 0.741로 분석되었다. 따라서 관자뼈 CT 스캔에서 알고리즘 변경적용은 CT 검사로 발생하는 선량을 일부 감소시킬 수 있고 임상 기초자료 측면에서 매우 의미가 있다고 생각한다.

흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과 (Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning)

  • 이종석;권대철;유병규
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.225-231
    • /
    • 2009
  • CT검사에 따른 방사선 선량의 유해성에 대한 관심이 고조되고 있어, 고정관전류기법과 AEC(automatic exposure control)를 적용하여 선량의 감소 효과를 비교하였다. 64MDCT를 이용하여 인체조직등가물질 팬텀으로 흉부 및 복부 부위를 고정관전류기법과 AEC를 적용하여 CTDIvol과 DLP를 비교하였고, 영상의 평가는 관심영역으로 CT감약계수와 노이즈를 측정하여 비교하였다. 흉부에서 고정관전류기법과 AEC적용에 따른 선량감소 효과는 CTDIvol 35.2%, DLP 49.3%, 복부에서는 CTDIvol 5.9%, DLP 3.2% 감소 효과가 있었다. CT검사에서 자동노출장치인 AEC를 이용하여 선량의 감소효과가 있다. CT 검사에 따른 환자의 피폭선량을 줄이기 위해서는 AEC를 이용하여야 한다.

Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석 (Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method)

  • 강수홍;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

Low-dose CT Image Denoising Using Classification Densely Connected Residual Network

  • Ming, Jun;Yi, Benshun;Zhang, Yungang;Li, Huixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권6호
    • /
    • pp.2480-2496
    • /
    • 2020
  • Considering that high-dose X-ray radiation during CT scans may bring potential risks to patients, in the medical imaging industry there has been increasing emphasis on low-dose CT. Due to complex statistical characteristics of noise found in low-dose CT images, many traditional methods are difficult to preserve structural details effectively while suppressing noise and artifacts. Inspired by the deep learning techniques, we propose a densely connected residual network (DCRN) for low-dose CT image noise cancelation, which combines the ideas of dense connection with residual learning. On one hand, dense connection maximizes information flow between layers in the network, which is beneficial to maintain structural details when denoising images. On the other hand, residual learning paired with batch normalization would allow for decreased training speed and better noise reduction performance in images. The experiments are performed on the 100 CT images selected from a public medical dataset-TCIA(The Cancer Imaging Archive). Compared with the other three competitive denoising algorithms, both subjective visual effect and objective evaluation indexes which include PSNR, RMSE, MAE and SSIM show that the proposed network can improve LDCT images quality more effectively while maintaining a low computational cost. In the objective evaluation indexes, the highest PSNR 33.67, RMSE 5.659, MAE 1.965 and SSIM 0.9434 are achieved by the proposed method. Especially for RMSE, compare with the best performing algorithm in the comparison algorithms, the proposed network increases it by 7 percentage points.

CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과 (Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography)

  • 정미영;권대철;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.307-312
    • /
    • 2009
  • CT 검사에서 수정체 차폐용 비스무트(bismuth)를 사용하여 수정체 선량의 감소효과를 유리선량계로 측정하여 비스무트 차폐효과 및 영상을 평가하였다. 안구 및 두부 CT 검사에서 차폐용 비스무트를 사용하여 수정체 선량의 감소와 차폐 효과를 평가하기 위해 인체모형 팬텀으로 유리선량계를 이용하여 수정체 선량을 평가하였다. 유리선량계를 이용하여 비스무트를 사용하기 전의 평균 선량은 21.54 mGy이었고, 사용 후의 선량은 10.46 mGy로 51.3%의 선량 감소효과가 있다. 차폐용 비스무트를 사용한 안구 64 MDCT 촬영에서 선량감소 효과가 있어 수정체를 포함한 안구 CT 스캔에서는 비스무트를 사용하여 검사하도록 권고한다.

  • PDF

흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교 (Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol)

  • 이원정;안봉선;박영선
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2012
  • 임상에서 사용하고 있는 흉부 CT촬영의 저선량 프로토콜과 표준선량 프로토콜 간의 선량과 화질을 비교 분석하였다. 흉부 저선량 프로토콜(120 kVp, 30 mAs)과 표준선량 프로토콜(120 kVp, 180 mAs)로 촬영($Brilliance^{TM}$ CT 16slice, PHILIPS)한 61명의 조영제를 사용하지 않은 영상에서 기관 분기부 위치의 종격동 영상을 본 연구를 위해 사용하였다. 상행대동맥과 가시아래근에서 CT number와 잡음을 측정하였고, Back-ground 잡음을 측정하여 신호대잡음비(signal-to-noise ratio. SNR)와 대조도잡음비(contrast-to-noise ratio, CNR)를 구하였다. 두부 아크릴 팬텀을 이용하여 선량을 측정하였고, 워터 팬텀으로 얻은 영상에서 CT number와 잡음을 측정하였다. 모든 측정은 3회 실시하여 평균값을 SPSS 프로그램(version 14.0)으로 분석하였고, 그래프는 시그마 플롯 프로그램(version10.0)을 사용하였다. 결과: 상행대동맥과 가시아래근에서 저선량 프로토콜 영상이 표준선량 프로토콜 영상 보다 유의하게 높은 잡음을 보였고, SNR과 CNR은 유의하게 낮았다. 두 영상에서 비만지수에 대한 잡음은 양의 관련성을 보였지만, SNR과 CNR은 음의 관련성을 보였다. 팬텀 결과에서 저선량 프로토콜의 선량이 표준선량 프로토콜 보다 유의하게 낮았지만(0.35 mGy vs. 1.95 mGy, p=0.008), 잡음은 저선량 프로토콜에서 유의하게 높았다(p=0.029). 저선량 프로토콜이 표준선량 프로토콜 보다 유의하게 낮은 선량을 보였지만, 화질 평가도 유의하게 낮은 결과를 보임으로서 임상에서 사용하는 저선량 프로토콜의 노출 선량은 화질을 고려하여 상향 조정할 필요가 있다.

Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가 (Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact)

  • 이충환;윤인하;홍동기;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.85-95
    • /
    • 2010
  • 목 적: 두경부 환자의 CT simulation시 metal artifact가 발생하여 영상의 질 저하와 선량계산의 오차를 유발 할 수 있어 metal artifact를 줄이기 위한 gantry tilt scan의 유용성을 평가하고자 한다. 대상 및 방법: Metal artifact를 줄이기 위하여 $20^{\circ}$ gantry tilt scan하여 $0^{\circ}$로 재구성한 이미지를 획득하였다. AAPM CT performance Phantom을 이용하여 CT number를 비교 분석하고, 아크릴 팬텀을 이용하여 체적의 일치여부를 확인하였다. Metal artifact에 의한 영향을 평가하기 위해 Intensity volume Histogram (IVH)을 통한 CT number의 균질성 및 Dose Volume histogram (DVH)을 통한 선량평가를 시행하였다. 결 과: CT number와 체적의 비교에서는 차이가 0.5% 이하로 나타났다. IVH를 비교 분석결과 gantry tilt scan에서 artifact에 의한 영향이 감소되어 CT number의 균질도가 향상되고, DVH 비교결과는 양쪽 이하선의 0.2~6%의 평균선량 오차를 감소시켰다. 결 론: Head & Neck 방사선치료 시 metal artifact 때문에 체표윤곽의 구별이 어렵고 선량의 오차가 발생한다. Gantry tilt scan을 이용하면 정확한 조직의 묘사가 가능하고, CT number 균질도가 향상되어 선량의 오차를 줄일 수 있었다. Gantry tilt scan 은 Head & Neck 방사선치료 시 정확한 방사선치료에 매우 유용함을 확인하였다.

  • PDF

지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가 (Assessment of DRL for Computed Tomography in Local Hospital)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.619-625
    • /
    • 2022
  • 영상의학 분야에서 컴퓨터단층촬영(Computed Tomography, CT) 검사는 가장 보편화된 검사 방법 중의 하나이고 병원에서 이용 빈도가 매우 높은 검사 방법 중의 하나이다. 그러나 다른 검사 방법에 비해 매우 높은 방사선 피폭을 동반한다. 피폭 저감화를 위해서 CT 검사가 꼭 필요한 경우만 검사를 시행하는 방법과 꼭 필요해서 검사를 시행하는 경우에도 검사의 목적에 부합하고 적은 선량으로 검사를 시행할 수 있는 프로토콜을 사용해야 한다. 본 연구에서는 지역의 대표적 종합병원에서 사용하고 있는 가장 최신의 방사선량 사용정보를 알아보고 진단기준수준(Dignostic Reference Level, DRL)을 개발하고자 하였다. 실험결과 두부 CT, 복부 CT검사에서 DLP는 NRPB(U.K) 와 Korea DRL보다 높게 나타났다. 흉부 CT의 사용 DLP 값은 CT장치 3종 모두 낮게 나타났다. 해당 병원에서는 CT 검사 시 피폭 저감화를 위한 노력을 해야 하는 것을 알 수 있었고 특히 두부 CT, 복부 CT에서 피폭 저감의 노력이 필요하다고 판단한다.

PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과 (Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method)

  • 정승우;김홍균;권재범;박성욱;김명준;신영만;김영헌
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.127-133
    • /
    • 2014
  • PET/CT에서 환자피폭 문제로 인해 저 선량의 중요성이 강조되고 있다. 본 연구에서는 기존에 사용되던 CT 데이터를 이용한 감쇠보정법인 CTAC와 새롭게 적용된 Q.AC를 환자실험과 팬텀 실험을 통해 저 선량으로 촬영 시 PET 영상에 미치는 영향에 대해 알아보고자 한다. 실험장비는 GE사의 PET/CT Discovery 710 (GE Healthcare, USA)를 사용하였으며 팬텀실험으로 감쇠보정의 정량적 평가를 위한 NEMA IEC body phantom과 균일성 평가를 위한 Uniform NU2-94 phantom을 사용하였다. 각각의 팬텀 내부에 동위원소 18-F FDG를 70.78 MBq, 22.2 MBq 주입하고 CT조건은 저 선량조건으로 80 kVp, 10 mA로부터 일반선량 조건으로 140 kVp, 120 mA 조건까지 스캔 후 CTAC와 Q.AC 두 감쇠보정법을 적용하여 재구성하였다. PET 영상에서 일반선량 조건을 기준값으로 정하고 horizomtal profile과 vertical profile을 통해 정량평가를 시행하고 기준값과의 상대적 오차를 평가하였다. 또한 환자실험으로 정상체중 환자와 과체중 환자를 구분하여 저 선량과 일반선량으로 비교 촬영한 뒤 CTAC와 Q.AC로 재구성된 PET영상에서 주요장기별 SUV에 대한 상대적 오차와 신호 대 잡음비를 비교분석하였다. 팬텀실험 결과 저선량 조건에서 CTAC와 Q.AC로 각각 재구성한 PET 영상의 profile과 상대적 오차에서 CTAC보다 Q.AC가 기준값과의 오차가 적은 그래프를 얻었다. 환자실험의 경우 일반선량 조건에서는 정상체중 환자와 과체중 환자 모두 감쇠보정법에 따른 상대적 오차값의 변화가 적었으나 저 선량 조건에서는 정상체중 환자보다 과체중 환자에서 감쇠보정법의 변경에 의한 상대적 오차의 감소폭이 커짐으로 기준값과 차이가 감소하였다. 기존의 감쇠보정법인 CTAC는 80 kVp, 10 mA의 저선량 CT를 사용하는데 있어 PET 영상의 선속경화현상이 발생한다. 이로 인해 CTAC를 이용하여 재구성된 PET 데이터는 정량화하는데 문제가 될 수 있음을 확인했다. 반면에 새로운 알고리즘이 적용된 Q.AC는 과체중 환자의 경우 80 kVp, 10 mA 정도까지는 140 kVp, 120 mA 조건으로 촬영하여 재구성한 PET 데이터 결과와 차이가 적음을 확인할 수 있었다. Q.AC를 이용한 경우 기존보다 저 선량의 CT를 이용해 PET의 재구성에 이용할 수 있으므로 환자의 피폭을 줄이는 데 큰 역할을 할 것으로 기대한다.

  • PDF