• Title/Summary/Keyword: COP1

Search Result 520, Processing Time 0.03 seconds

Themodynamic Characteristics of a Two-Stage Binary Absorption Cycle (2단(段) 2원(元) 흡수(吸收)사이클의 특성(特性)에 관(關)한 연구(硏究))

  • Lee, Y.H.;Rie, D.H.;Kashiwagi, T.;Seo, J.Y.
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.29-38
    • /
    • 1995
  • This paper concerns the study of a two-stage binary absorption cycle employing the refrigerant/absorbent combinations of $LiBr/H_2O$ and $NH_3/H_2O$. This cycle consists of coupling two single-effect absorption cycles so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effect of operating variables such as evaporator temperature, condenser and absorber temperature, and generator temperature on the coefficient of performance and temperature lift have been studied for two-stage binary absorption heat pump systems. It is found that this cycle has a large temperature lift at $105^{\circ}C$ of optimum generator temperature to obtain $50^{\circ}C$ of condenser temperature.

  • PDF

A Study of Performance Characteristics on Hybrid Heat Pump System with Solar Energy as Heat Source (태양열이용 하이브리드 열펌프시스템의 성능특성에 관한 연구)

  • Park, Youn-Cheol;Kim, Ji-Young;Ko, Gwan-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2007
  • Interests on renewable energy are increased due to oil price and environmental problems aroused from the fossil energy usage. In this study, performances of a solar assisted hybrid heat pump system are analyzed by experimental method. The developed system could runs at two types of operating mode. When the storage temperature is higher than the set temperature, the stored hot water in storage tank is supplied to the load directly. On the other hand, when the storage temperature lower than the set temperature, the water inside of the storage tank is used as heat source of the heat pump. In this study, the system control temperature for the alternation of the operating mode is set to $40^{\circ}C$ of the storage tank outlet. As results, it is founded that the COP of the developed heat pump system shows between 3.0 and 3.5. It is resonable performance for the heating system with a renewable energy as secondary heat source. The solar collect used in this study could supplies heat to the storage tank at over 400 W/m2 solar intensity. If the irradiation is lower than the 400 W/m2, the circulation pump stored and it could not supply heat to the storage tank. It is found that the difference temperature between the outlet of the storage tank and collector is $3^{\circ}C$. Even though, the extended study should be conducted to get a optimum performance of the developed system with various operating condition and control strategies.

A Study on Finding Ways to Reduce the Emission of Target Greenhouse Gases for Various Scenarios Utilizing the Building Energy Efficiency Rating (건물에너지 효율등급 제도를 이용한 시나리오별 목표 온실가스 저감방안에 관한 연구)

  • Bang, Young-Hyun;Kang, A-Ram;Park, Hyo-Soon;Suh, Seung-Jik
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.89-94
    • /
    • 2012
  • The international community is paying close attention to the climatic changes caused by the meteorological anomalies. In response to such phenomena, after the adoption of the United Nations Framework Convention on Climate Change in 1992, efforts to actively respond to the meteorological changes are proliferating all over the world; even in the Republic of Korea, the issue to tackle the meteorological changes has emerged as a top-priority national agenda. In the year of 2008, after the declaration of the low-carbon, green-growth paradigm by the government, the UNFCCC COP15 has announced a 30% reduction target of the emission of the greenhouse gases by 2020 as compared to the "Business As Usual, BAU" and has also confirmed, as a commitment plan to achieve reduction in the emission of greenhouse gases, the reduction target of greenhouse gases for all sectors, industries and years. (26.9% for buildings) Since the construction of the new apartment houses in the year of 2001, the "Building Energy Efficiency Rating", has been applied to newly constructed building complexes, built in 2010; the accumulated emission reduction has been evaluated at around 450,000toe and the accumulated carbon dioxide emission reduction is at $826,000tCO_2$ And through the prediction of these values under various scenarios (New construction, new construction / expansion of existing uses, when transferred to 1stgrade), the effects on the degree of reduction of greenhouse gases by the increased certification of the Building Energy Efficiency Rating are an alyzed and it is our aim to express the importance of the certification system capable of carrying out a quantitative evaluation of the building energy in order to establish the strategy to reduce the emission of carbon dioxide.

World Wide Views on Climate and Energy 2015 in Korea as a Global Deliberative Governance ('지구적 숙의 거버넌스'로서 유엔기후변화협상에 관한 세계시민회의)

  • Lee, Young Hee;Jeong, In Kyung
    • Journal of Science and Technology Studies
    • /
    • v.15 no.2
    • /
    • pp.1-31
    • /
    • 2015
  • World Wide Views on Climate and Energy held on 6 June 2015 was a structured citizens' deliberative consultation forum involving 10,000 citizens in 77 countries, and South Korea was one of the participating countries. Citizen participants, selected to reflect the demographic diversity in their countries or regions, were given information beforehand and deliberated for a full day with other citizens and voted on an identical set of questions, designed to reflect policy controversies at the UN COP negotiations to be held in Paris on December 2015. This study, firstly, analyzes the backgrounds and purposes of World Wide Views on Climate and Energy and reports the WWViews event held in Seoul, Korea before examining the theoretical implication of it. And then, this study discusses about the features and opportunities of World Wide Views on Climate and Energy as a way of forming a global deliberative governance by focusing on deliberative democracy, citizen participatory governance, and global citizenship.

Difference of Ground Reaction Force and Center of Pressure Parameters according to Levels of Education during Chest Compression Resuscitation (가슴압박소생술 시 교육수준에 따른 지면반력 및 압력중심의 차이)

  • Han, KiHoon;Gil, Ho-Jong;Lee, Mi-Kyoung;Park, Joonsung;Kim, Jongbin
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.220-225
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the effect of levels of education on ground reaction force and center of pressure parameters during chest compression resuscitation. Method: Twenty male university students were divided into two groups; certified group (CG, n=10) and non-certified group (NCG, n=10). Two force plates were used to measure ground reaction force and center of pressure parameters during 30 times (three trials) chest compression resuscitation. Independent t-tests were used to compare ground reaction force and center of pressure parameters between two groups. An alpha level of 0.05 was used in all tests. Results: All chest-compression time parameters (total time, 1 systolic time, and diastolic time) in CG were significantly shorter than those in NCG (p<.05). Fy of the diastolic and Fz of the systolic in CG revealed significantly the larger GRF values and Fy of the systolic in CG showed significantly the smaller GRF value (p<.05). The standard deviation of Fz of the systolic and diastolic within the subject during 30 times chest-compression resuscitation revealed significantly the smaller values in CG (p<.05). Conclusion: First, CG performed chest compressions efficiently at an appropriate rate compared to NCG. Second, CG showed lower Fx and Fy values in both the mediolateral and anteroposterior axes compared to NCG, which reduced unnecessary chest-compression force consumption and minimized the movement in patients with cardiac arrest. Third, CG showed high Fz value of the systolic and low Fz value of the diastolic. Based on this, chest compression resuscitation was performed to increase the survival rate of cardiac arrest patients.

Hydrological impact assessment of anthropogenic climate change: Pakistan flood in 2022 (인간 활동에 의한 기후변화의 수문학적 영향 평가: 2022년 파키스탄 홍수)

  • Jin Pak;Suyeon Moon;Yusuke Satoh;Hyungjun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.327-327
    • /
    • 2023
  • 인간 활동의 영향으로 인한 기후변화는 지구의 물 순환을 변화시키며 결과적으로 수문학적 재해의 발생빈도와 강도를 변화시킬 것으로 전망한다. 파키스탄은 기후변화에 대한 기여도가 적음에도 불구하고 기후변화로 인한 피해가 큰 나라 중 하나이다. 파키스탄은 2022년 여름 국가의 30% 이상의 지역이 침수되며 3300만명이 피해를 받은 기록적인 홍수를 겪은 바 있다. 본 연구에서는 하천 물리 모델인 Catchment based Macro-scale Floodplain (CaMa-Flood)를 사용하여 2022년 파키스탄에서 발생한 홍수에 대하여 인간 활동에 의한 기후변화 영향을 평가했다. 결합모델간 상호비교 프로젝트 (Coupled Model Intercomparision Project Phase 6, CMIP6)에 참여한 모형들 중, 일 유출량을 제공하는 4개의 전구기후모델 (CanESM5, CNRM-CM6-1, HadGEM3-GC31-LL, IPSL-CM6A-LR)을 선정하였다. 본 연구는 선정된 모델을 기반으로 지난 1950-2014년의 총 65년간, 인간의 영향을 제외한 hist-nat과 인간의 영향이 포함된 historical 시뮬레이션 결과를 비교하여 홍수에 대한 인간 활동의 기여도를 평가하였다. 각 hist-nat과 historical 시뮬레이션에서 산출된 일 유출량을 CaMa-Flood의 입력 자료로 사용하여, 파키스탄 지역의 자연 변동성 및 인위적 강제력이 영향을 미치는 하천 유량, 저수량, 범람 면적 및 수위 등을 계산하였다. 연구 결과, 인간 활동이 2022년 파키스탄 홍수의 하천 범람 면적 및 총 하천 유량 증가에 영향을 미쳤으며, 이는 자연 변동성만을 고려한 hist-nat 시뮬레이션과의 비교를 통해 차이를 확인하였다. 이는 향후 파키스탄 지역에서 발생하는 홍수 사례 전망 및 유엔 기후변화협약당사국총회(COP27)에서 의제로 채택된 기후변화로 인한 손실과 피해의 보상에 대한 구체적인 근거에 도움이 될 것으로 보인다.

  • PDF

Risk Assessment of Smoke Generated During Combustion for Some Wood (일부 목재의 연소 시 발생되는 연기의 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.373-380
    • /
    • 2022
  • In this study, Chung's equations 1, 2, and 3 were extended to standardize smoke safety rating evaluation in case of fire, and Chung's equations-V, smoke performance index-V, and smoke growth index-V were calculated. Five types of wood were selected and their smoke indices were measured using the cone calorimeter method according to ISO 5660-1. The smoke risk was graded by the smoke risk index-VI according to Chung's equation-VI. Smoke risk index-VI increased in the order of PMMA (1) ≈ maple (1.01) < ash (1.57) < needle fir (4.98) < paulownia (46.15) < western red cedar (106.26). It was predicted that maple and ash had the lowest smoke risk, and paulownia and western red cedar had the highest. The five samples' CO mean production rate (COPmean) was 0.0009~0.0024 g/s, indicating that these woods were incompletely burned than the polymethyl methacrylate (PMMA) reference material. Regarding the smoke properties of the chosen woods, the smoke performance index-V (SPI-V) increased as the bulk density increased, and the smoke risk index-VI (SRI-VI) decreased.

A Review on the International Trends for Establishing Post-2020 National Targets Relevant to Protected Areas - Focused on the CBD Decisions and Aichi target-11 Achievement Status - (Post-2020 국가 보호지역 목표 설정을 위한 국제동향 고찰 - 생물다양성협약 결정문 및 글로벌 목표 성취현황 분석을 중심으로 -)

  • Heo, Hag Young
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.6
    • /
    • pp.601-609
    • /
    • 2020
  • This study aims to draw suggestions for establishing the Post-2020 national policy direction and goals related to protected areas in Korea by analyzing the trends of major discussion issues on protected areas in the Convention on Biological Diversity (CBD) and reviewing the achievement progress of the Aichi target-11. Regarding the CBD decisions on protected areas, two decisions (Decisions II/7 and II/8) were adopted in 1995, and then the Program of Work on Protected Areas (PoWPA), which presented an ideal blueprint for protected areas, was adopted at the 7th Conference of the Parties (COP) in 2004. At the 10th COP in 2010, the "Strategic Plan for Biodiversity 2011-2020 and the Aichi Biodiversity Target" (Decision X/2) was adopted along with the Decision X/31, which presented ten key issues related to protected areas. The global outcomes of the Aichi Target-11 include 15% of the earth's land area and 7.4% of the ocean being designated as protected areas. In Korea, 16.63% of the land and 2.12% of the ocean have been designated as protected areas. However, the outcomes of the effective and equitable management, protection of areas important to biodiversity and ecosystem services, and identifying "Other effective area-based conservation measures" (OECMs) and linking them with protected areas have been found to be significantly short of global goals. The first draft of the Post-2020 Global Biodiversity Framework (Post-2020 GBF) prepared in January 2020 presented multi-step objectives. They included protecting at least 60% of particularly important sites for biodiversity through protected areas and other effective area-based conservation measures, at least 30% of the entire land and sea areas, and at least 10% of them under strict protection by 2030. The Updated Zero drafted in August 2020 concisely set out one quantitative goal of at least 30% of the globe by 2030, adding qualitative goals that these areas should be protected and conserved through "well connected and effective system of protected areas and OECMs at least 30 % of the planet with the focus on areas particularly important for biodiversity." Based on the draft Post-2020 GBF's targets related to protected areas and Korea's national targets reflecting the current state of Korea and established national plans, we suggest the national targets "to protect and conserve at least 30% of the land area and 10% of the marine area and to strengthen the means of qualitative achievement by establishing sub-targets through an effective system of protected areas and OECMs by 2030.".

Considerations of Countermeasure Tasks in the Fields of Forest and Forestry in Korea through Case Study on "The Nagoya Protocol (Access to Genetic Resources and Benefit Sharing)" ("유전자원의 접근과 이익공유(ABS)" 사례연구를 통한 국내 산림·임업분야 대응과제 고찰)

  • Lee, Gwan Gyu;Kim, Jun Soon;Jung, Haw young
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.3
    • /
    • pp.522-534
    • /
    • 2011
  • The aim of this study is to draw forth the tasks for establishing the right of native biology in Korea through the case study on 'Access on genetic resources and Benefit Sharing'. For this purpose, this study decided on its research subject by selecting Hoodia, on which ABS treaty was made the most recently, through the examination of the representative ABS precedents on plant species. This study analyzed the process background of ABS on Hoodia, and compared & analyzed the ABS procedures of 'Bonn Guidelines' adopted by the 6th Conference of the Parties of the Convention on Biological Diversity in 2002 and Hoodia case. Together with the ABS major issues in common drawn as a result of this analysis, and "Nagoya Protocol" adopted by the 10th Conference of the Parties of the Convention on Biological Diversity, this study intended to shed a light on the impending tasks which Korea faces at present and its role relationship. The research results are as follows: 1. It is required that species habitats should be divided based on biological classification and its subsequent community should be established with the development of infrastructure such as a community's independent production, management and monitoring of bio-species. 2. There needs to be a designation of ABS National Focal Point for sharing of ABS-related general information, boosting of implementation of the relevant convention. 3. There needs to be the establishment of ABS convention system consequent on legislative, administrative, political procedures, and designation of the Competent National Authorities for the provision of the format of Prior Informed Consent (PIC) and Mutually Agreed Terms (MAT) and their contents assessment and confirmation. 4. There should be the establishment of integrated management system of ABS-related research and development of forest biological resources and its relevant research projects. 5. There should be information development through the distribution of responsibility and role between the ministries and offices concerned according to bio-resources, and there needs to be efforts in aiming for opening a working group of academic-industrial institutions for developing a mutually interchangeable system. 6. It's required that the efficient access between industrial circles and the people should be promoted by setting up ABS support center of biological resources in ministry and office's charge. 7. There should be a selection of a national supervisory organization for securement of the right of a local community and monitoring of ABS convention implementation, and a countermeasure system for preventing outflow of forest bioresources. Conclusively, it's judged that it will be possible to inquire into the countermeasures for the establishment of the native forest biology dominion through such research results.

Simulation Study on the Cooling Performance of the Two-Stage Compression CO2 Cycle with the a Flash Intercooler and Flash Gas Bypass (플래쉬 중각냉각기와 플래쉬 가스 바이패스를 이용한 이단압축 이산화탄소 사이클의 냉방성능에 관한 해석적 연구)

  • Kwak, Myoung-Seok;Cho, Hong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.17-24
    • /
    • 2012
  • There has been little study on the performance characteristics of the effective heat pump systems in the cooling mode using the two-stage compression cycles have hardly performed. In this study, the performance of the two-stage compression $CO_2$ cycle with an FI (flash intercooler) and the FGB (flash gas bypass) was investigated by using a theoretical method. The performance analysis was carried out with aby varyingiation (the indoor temperature, outdoor temperature, and 1st- and 2nd-stage EEV openings. As of a result, the coefficients of performance (COPs) of the Bbasic, FI, and FGB cycles were decreased by 28.5%, 22.1%, and 24.5%, respectively, for various outdoor temperature conditions. In addition to, the performance variation of the two-stage compression cycle was smaller than that of the single-stage compression cycle. The performance of the FI and FGB cycles was improved by 13.5%, and 6.9%, respectively, when the 1st-stage EEV opening was increased from 32% to 48%, and by 0.9%, and 2.6%, respectively, when the 1st- andthe 2nd-stage EEV opening was increased from 32% to 48%, andwas increased from 42% to 58%, respectively. The FI cycle showed anthe most improved performance for any given operating conditions.