• Title/Summary/Keyword: CO Detection

Search Result 1,819, Processing Time 0.029 seconds

Improvement in Characteristics of Thin Film Transistors by High Pressure Steam Annealing

  • Nagasawa, Y.;Yamamoto, N.;Chishina, H.;Ogawa, H.;Kawasaki, Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.333-336
    • /
    • 2006
  • High Pressure Annealing System was developed to improve the characteristics of low-temperature poly-silicon thin film transistors.. (TFTs). The high-pressure steam annealing was applied to the poly-silicon film made by rapid thermal annealing method. The carrier lifetime was investigated by Microwave detection of the Photo-Conductive Decay and the increase of carrier lifetime which indicates the reduction of the defect was observed by high-pressure steam annealing of 1MPa 600C 1hour.

  • PDF

CO OBSERVATIONS OF A HIGH VELOCITY CLOUD

  • Kim, K.T.;Mihn, Y.C.;Hasegawa, T.I.
    • Journal of The Korean Astronomical Society
    • /
    • v.22 no.1
    • /
    • pp.25-30
    • /
    • 1989
  • We report a null detection of $^{12}CO$ emission from a sub-condensation in a High Velocity Cloud (HVC). As a consequence of this, an upper limit of $n(H_2)\frac{X(CO)}{DV/DR}{\leq}2{\times}10^{-5}$ was set. This implies that $^{12}CO$ abundance is deficient by at least a factor of 10 if the HVC is predominantly molecular, otherwise the CO abundance of the HVC might be normal.

  • PDF

Detection of Absolute Position of Robot Joint Using Incremental Encoders (증분형 엔코더를 이용한 로봇 관절의 절대위치 검출)

  • Lim, Jae Sik;Lee, Young Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.577-582
    • /
    • 2015
  • This paper proposes an efficient detection of absolute position of a robot joint using two incremental encoders. We considers a robot joint comprising a motor, a reducer, two encoders, and a motor drive. An incremental(first) encoder provides motor's rotor position or input position of reducer while another incremental(second) encoder does output position of the reducer. A table is made where the relationship between the first and the second encoder counts is recorded. The key point is placed where the table is constructed: when a pulse occurs in the second encoder, there exists a corresponding unique count value of the first encoder. The absolute position is detected using the table by searching the second encoder position corresponding to the first encoder count value when a pulse occurs in the second encoder. The proposed method needs a small rotation, as just one second encoder's pulse angle, for the initial absolute position detection.

A Study on the Substation for the Bad Measuring Devices Detection and Correction (변전소 측정기기의 검.교정 알고리즘에 관한 연구)

  • Lee, H.J.;Park, S.M.;Kim, Y.H.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.313-315
    • /
    • 2001
  • The power system automation, especially the substation automation is a major issue. so it has been widely studied each country in the world. Since the substation system includes lots of measuring devices. a lot of data and system information are transmitted to operators. The measured values usually have the error that results from the communication process, and it can degrade the reliability of estimated values. So. the detection and correction of measured values at a substation are important factors for substation automation. In this paper, we study the detection and col of measured values at the domestic 154kV/2 distribution substation of double bus structure study will be useful for expected economic dispatch measuring device's inspection and corr management by SCADA system operation, substation automation.

  • PDF

Detection of Individual Tree Stands by a Fusion of a Multispectral High-resolution Satellite Image and Laser Scanning Data

  • Teraoka, Masaki;Setojima, Masahiro;Imai, Yasuteru;Yasuoka, Yoshifumi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1042-1044
    • /
    • 2003
  • A methodology of the integrating the similar color circle search of the spectral data and segmentation of the height data is developed. The method is then applied to study areas, and the results by IKONOS, LIDAR and data fusion are verified with the ground truth, and examined in terms of the accuracy. Results show that with the data fusion the accuracy are improved by about 15% in most of the study areas. The methodology for the detection of individual tree stands by data fusion is explored, and the utility of combinatorial use of the spectral and the height information is demonstrated.

  • PDF

Target Geolocation Method Using Target Detection in Infrared Images (적외선 영상의 탐지 정보를 이용한 표적 geolocation 기법)

  • Kim, Jae-Hyup;Jeong, Jun-Ho;Seo, Jeong-Jae;Lee, Jong-Min;Moon, Young-Shik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.3
    • /
    • pp.57-67
    • /
    • 2015
  • In this paper, we proposed the geolocation method using target detection information in infrared images. Our method was applied to geolocation system of hostile targets in ground-to-ground field. The major distortion that has bad effect of geolocation was composed of optic, topography, GPS(Global Positioning System) and IMU(Inertial Measurement Unit) of reconnaissance unit. We proposed enhanced geolocation method to cope with optic and topography distortion using polynomial fitting and slant-range calculation model to overcome earth curvature problem, and the result showed that the performance of our method was good for system requirements.

Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load (중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법)

  • Oh, Hyeong-Min;Choi, Se-Wan;Kim, Tae-Hee;Lee, Gi-Pung;Lee, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

Detection and Location of Cable Fault Using Improved SSTDR (개선된 SSTDR을 이용한 케이블 고장 검출과 위치 계산)

  • Jeon, Jeong-Chay;Kim, Jae-Jin;Choi, Myeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1583-1589
    • /
    • 2016
  • This paper proposes an improved spread spectrum time domain reflectometry (ISSTDR) using time-frequency correlation and reference signal elimination method in order to have more accurate fault determination and location detection than conventional (SSTDR) despite increased signal attenuation due to the long distance to cable fault location. The proposed method has a two-step process: the first step is to detect a peak location of the reference signal using time-frequency correlation analysis, and the second step is to detect a peak location of the correlation coefficient of the reflected signal by removing the reference signal. The proposed method was validated through comparison with existing SSTDR methods in open-and short-circuit fault detection experiments of low voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

Development of Genus- and Species-Specific Probe Design System for Pathogen Detection Based on 23S rDNA

  • Park Jun-Hyung;Park Hee-Kyung;Kang Byeong-Chul;Song Eun-Sil;Jang Hyun-Jung;Kim Cheol-Min
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.5
    • /
    • pp.740-747
    • /
    • 2006
  • Amplification by universal consensus sequences in pathogenic bacterial DNA would allow rapid identification of pathogenic bacteria, and amplification of genus-specific and species-specific sequences of pathogenic bacterial DNA might be used for genotyping at the genus and species levels. For design of probes for molecular diagnostics, several tools are available as stand-alone programs or as Web application. However, since most programs can design only a few probe sets at one time, they are not suitable for large-scale and automatic probes design. Therefore, for high-throughput design of specific probes in diagnostic array development, an automated design tool is necessary. Thus, we developed a Web-based automatic system for design of genus-specific and species-specific probes for pathogen detection. The system is available at http://www.miprobe.com.

A Study on The Broken Rotor Bars in Induction Motor and The Controll Characteristics in Inverter (유도전동기 로터바의 손상과 인버터 제어특성에 관한 연구)

  • Kim K.W.;Kwon J.L.;Lee K.J.;Choi K.S.;Lee H.S.;Chang S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.464-466
    • /
    • 2001
  • The advantage of the squirrel cage induction motor is the brushless rotor. This advantage for operation and maintenance turns out to be a disadvantage for the detection of the cage rotor bar and endring defects, which means that the detection of cage faults is due to the measurement and analysis of only the stator input signals. The monitoring task in an inverter drive is complicated mainly because the voltage and current waveforms are nonsinusoidal and the high dv/dt values from fast switching inverterd distort the measurements. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA).

  • PDF