The Journal of the Korean bone and joint tumor society
/
v.15
no.1
/
pp.1-6
/
2009
The usefulness and accuracy of computer-assisted surgery have been evaluated clinically in many orthopedic fields, such as, joint replacement arthroplasty, cruciate ligament reconstruction, and pedicle screw placemen. Recently several preliminary reports have been issued on the application of navigation to bone tumor surgery. The main advantage of navigation-assisted bone tumor surgery is that it provides highly accurate three-dimensional radiological information for intraoperative guidance. In particular, distances from tumors to resection margins can be precisely determined using intraoperative three-dimensional images. Accordingly, the technique allows preservation of function to be maximized by minimizing unnecessary resection. However, surgeons should recognize that the accuracies of navigation systems in bone tumor surgery have some hidden pitfalls. Here, based on our clinical results, we describe the surgical techniques used and include some cautionary notes.
Screw-shaped implants of commercially pure (c.p.) titanium, c.p. niobium, c.p. zirconium, and stainless steel(Sus 304) were inserted in the rabbit tibial bone over 12 weeks of follow-up. New developed torque gauge instrument was used to evaluate the implant holding power and a image analysis program coupled to a microscope was used for histomorphometry. The three best consecutive threads of each implant were measured. Quantitative analyses at 12 weeks revealed a partial bone contact to the four kinds investigated metals. There were no obvious adverse tissue reactions to any of the biomaterials. At 12 weeks the average removal torques for titanium, niobium and zirconium were better than that needed for Sus 304 screws, on the other hand high score of bony contact ratio of titanium and niobium were showed in comparison to those of zirconium and Sus 304. There was no significant differences in the amount of interfacial bone of zirconium and Sus 304 whereas there was significant difference in the torque forces of niobium and Sus 304. Three months after implant insertion, the average removal torque was 6.64 Ncm for the titanium, 6.57 Ncm for the niobium, 6.38 Ncm for the zirconium, and 4.25 Ncm for the Sus 304. On average bone contacts there were 51.24% in the titanium, 48.19% in the niobium, 31.79% in the zirconium, 23.54% in the Sus 304. Biocompatibility of the titanium, niobium and zirconium was acceptable level in comparison to the Sus 304.
Purpose: This pilot study was conducted to develop a novel test setup for the in vitro assessment of the primary stability of dental implants. This was achieved by characterising their long-term behaviour based on the continuous recording of micromotions resulting from dynamic and cyclic loading. Methods: Twenty screw implants, each 11 mm in length and either 3.8 mm (for premolars) or 4.3 mm (for molars) in diameter, were inserted into the posterior region of 5 synthetic mandibular models. Physiological masticatory loads were simulated by superimposing cyclic buccal-lingual movement of the mandible with a vertically applied masticatory force. Using an optical 3-dimensional (3D) measuring system, the micromotions of the dental crowns relative to the alveolar bone resulting from alternating off-centre loads were concurrently determined over 10,000 test cycles. Results: The buccal-lingual deflections of the dental crowns significantly increased from cycle 10 to cycle 10,000 (P<0.05). The deflections increased sharply during the first 500 cycles before approaching a plateau. Premolars exhibited greater maximum deflections than molars. The bone regions located mesially and distally adjacent to the loaded implants demonstrated deflections that occurred synchronously and in the same direction as the applied loads. The overall spatial movement of the implants over time followed an hourglass-shaped loosening pattern with a characteristic pivot point 5.5±1.1 mm from the apical end. Conclusions: In synthetic mandibular models, the cyclic reciprocal loading of dental implants with an average masticatory force produces significant loosening. The evasive movements observed in the alveolar bone suggest that its anatomy and yielding could significantly influence the force distribution and, consequently, the mechanical behaviour of dental implants. The 3D visualisation of the overall implant movement under functional cyclic loading complements known methods and can contribute to the development of implant designs and surgical techniques by providing a more profound understanding of dynamic bone-implant interactions.
Park, Jin-Seo;Yu, Won-Jae;Kyung, Hee-Moon;Kwon, Oh-Won
The korean journal of orthodontics
/
v.39
no.4
/
pp.203-212
/
2009
Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion in a self-drilling manner. Methods: A 3D finite element method was used to simulate the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) into 1 mm thick cortical bone. The shape and dimension of thread groove in the center of the cortical bone produced by the cutting flute at the apical of the microimplant was obtained from animal test using rabbit tibias. A total of 3,600 analysis steps was used to calculate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, were observed in the peri-implant bone along the whole length of the microimplant. Level of strains in the vicinity of either the screw tip or the valley part were similar. Conclusions: Bone strains from a microimplant insertion in a self-drilling manner might have a negative impact on the physiological remodeling of cortical bone.
This is a report of 4 cases of the surgical correction of mandibular prognathism with chief complaint of mastication difficulty, facial asymmetry and protrusive chin. We performed sagittal spit ramus osteotomy for the prognathism, we used the repositioning plate for conserving the condylar segment into its original position and fixed the osteotomized bone segments rigidly with adjustable monocortical plate. Intermaxillary fixation was performed during 2 weeks. As a results, we found the following advantage. 1. Rigid fixation effect like the fixation by the tandem screw. 2. Decreased postoprative swelling. 3. It is needless to do the stab incision for the transbuccal set instrument. 4. It is more convenient to perform the rigid fixation in the monocortical plate method than screw technique.
Purpose: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. Materials and Methods: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. Results: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. Conclusion: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures.
The Journal of the Korean bone and joint tumor society
/
v.17
no.2
/
pp.73-78
/
2011
Purpose: This study was aimed to evaluate the result of inlay cortical strut bone grafts for large cysts or cavitary bone lesions in long bones. Materials and Methods: Seven patients with large cyst or cavitary bony lesions were managed with curettage, allogeneic inlay cortical strut and cancellous bone grafts. Additional plate and screw fixations were performed in 6 patients. There were three SBCs, two FDs with secondary ABC changes, one FD and one post-cement spacer removal state. Three of them had pathologic fractures. Progression of bone healing and mechanical support and functional result were evaluated. The mean follow-up period was 25.4 months. Results: Incorporations into host bones were progressed in all, average 4.2 months in six metaphyseal regions and 5.8 months in five diaphyseal regions respectively. Full structural supports were achieved in all except one patient without any additional procedures. No allograft-related complication was developed. Mean functional score according to the MSTS criteria was 29.6 at last follow up. Conclusion: Inlay cortical strut graft provided additional mechanical stability and bone stock for screw purchase in large cyst or cavitary defects of long bones, which allow early mobilization and excellent functional outcome.
Yi Yang-Jin;Yang Jae-Ho;Lee Sun-Hyung;Kim Yung-Soo;Kwon Sang-Ho
The Journal of Korean Academy of Prosthodontics
/
v.39
no.6
/
pp.659-681
/
2001
Platelet-rich plasma(PRP) has been known to increase the rate and degree of bone formation by virtue of growth factors in concentrated platelets. Although its great healing effect on bone defect or pre-implantation site preparation in conjunction with bone substitute has been reported, the effect associated with implant is unknown. The purpose of this study was to investigate the effect of PRP on rapid osseointegration of endosseous dental implants in the rabbit tibiae. Twenty two adult female New Zealand white rabbits, weighing approximately 2.7-3.3kg, were used for this study. Twelve of the 22 animals were used for histomorphometric analysis and ten of the 22 were for removal torque test. Each animal received two implants in each tibia (two treated with PRP and two as control) and was given fluorochrome intramuscularly. For histomorphometric analysis, rabbits were divided into four groups according to the healing period. At 1 week, 2 weeks, 4 weeks and 8 weeks postoperatively, each three animals were sacrificed serially and the amount and rate of bone formation around dental implant were examined on the undecalcified sections under fluorescent microscope, polarized microscope and light microscope connected to a personal computer equipped with image analysis system. For removal torque test, rabbits were divided into two groups and removal torque tests were performed at 4 weeks, 10 weeks after implant placement. In total, 88 screw shaped, commercially pure titanium implants (Neoplant, Neobiotech, Seoul, Korea) were used in this study. Labeling pattern reflected differences of two groups in bone formation rate at each period. Histomorphometrically, PRP group showed significantly higher bone volume within threads compared to control group at 2 weeks ($70.30{\pm}4.96%$ vs. $50.68{\pm}6.33%$; P < .01) and 4 weeks ($82.59{\pm}5.94%$ vs. $72.94{\pm}4.57%$; P < .05 ). PRP group at 1, 2 and 4 weeks revealed similar degree of bone volume formation comparable to control group at 2, 4 and 8 weeks, respectively. On the other hand, while PRP group showed higher bone-implant contact ($47.37{\pm}8.09%$) than control group ($33.16{\pm}13.47%$) at 2 weeks, there were no significant differences between PRP group and control group for any experimental period. Removal torque values also showed no significant differences between PRP group and control group at any experimental period (P > .05). These findings imply that PRP could induce rapid, more bone formation around implant during early healing period and get faster secondary stability for reducing healing period, though it has not induced bone maturation enough to resist functional loading.
Background: Crestal bone loss known as saucerization is a frequently observed phenomenon. Recent studies have shown that implants with micothreaded crest module reduced the force concentration in the crestal region thus resulting in no or reduced crestal bone loss. This study presents a clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface. Methods: The implants were placed in the mandible of 5 beagle dogs weighing 10-15kg. Four premolars were bilaterally extracted 8 weeks prior to implant placement. Mucoperiosteal flap was elevated and drilling with increasing diameter was performed under saline irrigation. After countersinking 2 implants were placed in each side resulting in 4 implants per dog. Healing period of 8 weeks was allowed before sacrificing the animals. Histologic preparation was performed for histologic and histometric analysis. Bone to implant contact as well as percentage of bone area inside threads were measured. T-test was used for statistical analysis with pvalue p<0.05. Results: 1. Healing was uneventful without any cover screw exposure. New bone formation around the implants was observed without any inflammatory infiltration. 2. Bone to implant contact in the microthread and thread were 43.90 ${\pm}$ 20.30 %, and 53.19 ${\pm}$ 20.97 % respectively. The overall bone to implant contact was 48.54 ${\pm}$ 20.95 %. 3. Percentage of bone area inside threads were 54.43 ${\pm}$ 10.39 %, and 38.44 ${\pm}$ 16.44 % for the microthread and thread respectively. There was statistically significant difference(p<0.05). The overall percentage of bone area inside threads was 46.67 ${\pm}$ 15.68 %.
Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.