References
- Park HS, Jeong SH, Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006;130:18-25 https://doi.org/10.1016/j.ajodo.2004.11.032
- Cheng SJ, Tseng IY, Lee JJ, Kok SH. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 2004;19:100-6
- Wilmes B, Rademacher C, Olthoff G, Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 2006;67:162-74 https://doi.org/10.1007/s00056-006-0611-z
- Rubin CT, Lanyon LE. Regulation of bone mass by mechanical strain magnitude. Calcif Tissue Int 1985;37:411-7 https://doi.org/10.1007/BF02553711
- Frost HM. Wolff's law and bone structural's adaptation to mechanical usage: an overview for clinicians. Angle Orthod 1994;64:175-88
- Frost HM. Bone's mechanostat: a 2003 update. Anat Rec A Discov Mol Cell Evol Biol 2003;275:1081-101 https://doi.org/10.1002/ar.a.10119
- Sugiura T, Horiuchi K, Sugimura1 M, Tsutsumi S. Evaluation of threshold stress for bone resorption around screws based on in vivo strain measurement of miniplate. J Musculoskel Neuron Interact 2000;1:165-70
- Isidor F. Loss of osseointegration caused by occlusal load of oral implants. A Clinical and radiographic study in monkeys. Clin Oral Impl Res 1996;7:143-52 https://doi.org/10.1034/j.1600-0501.1996.070208.x
- Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Impl 2003;18:357-68
- Petrie CS, Williams JL. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. Clin Oral Impl Res 2005;16:486-94 https://doi.org/10.1111/j.1600-0501.2005.01132.x
- Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-11
- Kitagawa T, Tanimoto Y, Nemoto K, Aida M. Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater J 2005;24:219-24 https://doi.org/10.4012/dmj.24.219
- Cha JY, Yun TM, Hwang CJ. Insertion and removal torques according to orthodontic mini-screw design. Korean J Orthod 2008;38:5-12 https://doi.org/10.4041/kjod.2008.38.1.5
- Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 2006;17:109-14 https://doi.org/10.1111/j.1600-0501.2005.01211.x
- Nam OH, Yu WJ, Kyung HM. Cortical bone strain during the placement of orthodontic microimplant studied by 3D finite element analysis. Korean J Orthod 2008;38:228-39 https://doi.org/10.4041/kjod.2008.38.4.228
- Meyer U, Vollmer D, Runte C, Bourauel C, Joos U. Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. Clin Oral Impl Res 2001;12:648-57 https://doi.org/10.1034/j.1600-0501.2001.120614.x
- Meyer U, Joos U, Mythili J, Stamm, T, Hohoff A, Stratmann U, et al. Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants. Biometerials 2004;25:1959-67 https://doi.org/10.1016/j.biomaterials.2003.08.070
-
Heidemann W, Gerlach KL, Gr
$\ddot{o}$ bel KH, K$\ddot{o}$ llner HG. Drill Free Screws: a new formof osteosynthesis screw. J Craniomaxillofac Surg 1998;26:163-8 https://doi.org/10.1016/S1010-5182(98)80007-3 - Kim JW, Ahn SJ, Chang YI. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2005;128:190-4 https://doi.org/10.1016/j.ajodo.2004.01.030
- Chen Y, Shin HI, Kyung HM. Biomechanical and histological comparison of self-drillingand self-tapping orthodontic microimplants in dogs. Am J Orthod Dentofacial Orthop 2008;133:44-50 https://doi.org/10.1016/j.ajodo.2007.01.023
- Heidemann W, Gerlach KL. Clinical applications of drill free screws in maxillofacial surgery. J Craniomaxillofac Surg 1999;27:252-5 https://doi.org/10.1016/S1010-5182(99)80037-7
- Park HS. Orthodontic treatment using micro-implant: clinical applications of micro-implant anchorage. 2nd ed. Seoul, Korea: Daehan Nare Pub Co; 2006. p. 18-9
- Sowden D, Schmitz JP. AO self-drilling and self-tapping screws in rat calvarial bone: an ultrastructual study of the implant interface. J Oral Maxillofac Surg 2002;60:294-9 https://doi.org/10.1053/joms.2002.30585
- Maniatopoulos C, Pilliar RM, Smith D. Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model. J Biomed Mater Res 1986;20:1309-33 https://doi.org/10.1002/jbm.820200907
- Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of perimental literature. J Biomed Mater Res 1998;43:192-203 https://doi.org/10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K
- Pilliar RM, Lee GM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res 1986;208:108-13
Cited by
- 교정용 마이크로 임플란트의 나사산 디자인 최적화 vol.41, pp.1, 2009, https://doi.org/10.4041/kjod.2011.41.1.25
- 표면처리가 교정용 미니 임플랜트의 식립수직력과 토크에 미치는 영향 vol.41, pp.4, 2009, https://doi.org/10.4041/kjod.2011.41.4.268
- Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length vol.41, pp.6, 2011, https://doi.org/10.4041/kjod.2011.41.6.423