Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect

전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향

  • Shim, Jae-Chang (Department of Periodontology, College of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Kim, Young-Jun (Department of Periodontology, College of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Chung, Hyun-Ju (Department of Periodontology, College of Dentistry, Dental Science Research Institute, Chonnam National University) ;
  • Kim, Ok-Su (Department of Periodontology, College of Dentistry, Dental Science Research Institute, Chonnam National University)
  • 심재창 (전남대학교 치과대학 치주과학교실 및 치의학연구소) ;
  • 김영준 (전남대학교 치과대학 치주과학교실 및 치의학연구소) ;
  • 정현주 (전남대학교 치과대학 치주과학교실 및 치의학연구소) ;
  • 김옥수 (전남대학교 치과대학 치주과학교실 및 치의학연구소)
  • Published : 2004.03.30

Abstract

Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

Keywords

References

  1. Lewis S. Treatment planning: teeth versus implants. Int J Periodontics Restorative Dent 16:366-377, 1996
  2. Kinsel RP, Lamb RE, Ho D. The treatment dilemma of the furcated molar: root resection versus single-tooth implant restoration. A literature review. Int J Oral Maxillofacial Implants 13:322-332,1995
  3. Branemark P-I. Introduction to osseointegration. In Branemark P-I, Zarb GA, Albreksson T(eds): Tissue-integrated prostheses. Osseointegration in clinical dentistry. Chicago, Quint. Publishing Co., pp11-76, 1985
  4. Carlsson L, Rostlund T, Albrektsson B, Albrektsson T, Branemark PI. Osseointegration of titanium implants. Acta Orthop Scand 57:286-289, 1986
  5. Chang C-S, Matukas VJ, Lemons JE. Histologic study of hydroxyapatite as an implant material for mandibular augmentation. J Oral Maxillofac Surg 41:729-736, 1983
  6. Block MS, Kent JN. Long-term radiographic evaluation of hydroxyapatite-augmented mandibular alveolar ridges. J Oral Maxillofac Surg 42:793-805, 1984
  7. Javanovic SA, Spiekermann H, Richter EJ. Bone regeneration around titanium dental implants in dehisced defect sites: A clincal study. Int J Oral Maxillofac Implants 7:233-245, 1992
  8. Becker W, Schenk MD. Variations in bone regeneration adjacent to implants augmented with barrier membranes alone or with demineralized freeze-dried bone or autologous grafts: A study in dogs. Int J Oral Maxillofac Implants 10:143-154, 1995
  9. Carpio L, Loza J, Lynch S, Genco R. Guided bone regeneration around endosseous implants with anorganic bovine bone mineral. A randomized controlled trial comparing bioresorbalble versus non-resorbable barriers. J Periodontol 71:1743-1749, 2000
  10. White K, Rheude B, Kirkwood K, Dee K. Mineralization of Substrates Modified with BMP-7 Derived Peptides. American Society for Mechanical Engineers. 2001;Summer Bioengineering Conference #210
  11. Kirkwood K, Rheude B, Kim YJ, White K, Dee K. In vitro mineralization studies with substrate-immobilized bone morphogenic protein peptides. J Oral Implantol 29:57-65, 2003
  12. Stenport VF, Johansson CB, Sawase T, Yamasaki Y, Oida S. FGF-4 and titanium implants: a pilot study in rabbit bone. Clin Oral Impl Res 14:363-368, 2003
  13. Lazzara R. Immediate implant placement into extraction sites: surgical and restorative advantages. Int J Periodont Restorative Dent 9:333-344, 1989
  14. Calicchia F, Bravi F. Case reports offer a challange to treatment strategies for immediate implants. Int J Periodontics restorative Dent 11:67-81, 1991
  15. Gher ME, Quintero G, Assad D, Monaco E, Richardson AE. Bone grafting and guided bone regeneration for immediate implants in humans. J Periodontol 65:881-891, 1994
  16. Nemcovsky CE, Artzi Z. Comparative study of buccal dehiscence defects in immediate, delayed, and late maxillary implant placement with collagen membranes: clinical healing between placement and second-stage surgery. J Periodontol 73:754-761, 2002
  17. Yasuda I. Piezoelectricity of living bone. J Kyoto Med Soc 4:395-406, 1953
  18. Jahn TL. A possible mechanism for the effect of electrical potentials on apatite formation in bone. Clin Orthop 56:261-273, 1968
  19. Brighton CT, Adler S, Black J, Itada N, Friendenberg ZB. Cathodic oxygen consumption and electrically induced osteogenesis. Clin Orthop 107:277-289, 1975
  20. Bassett CAL, Mitchell SN, Gaston SR. Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields. J Bone Joint Surg 63-A:511-523, 1981
  21. Friendenberg ZB, Zemsky LM, Pollis RP, Brighton CT. The response of non-traumatized bone to direct current. J Bone Joint Surg 56:1023-1031, 1974
  22. Zengo AN, Basset CA, Pawluk RJ, Prountzos G. In vivo bioelectric potentials in the dentoalveolar complex. An J Orthod 66:130-141, 1974
  23. Chiarenza AR. The use of dental implants as cathodes for the DC stimulation of osteogenesis in alveolar bone. J Oral Implantol 5:466-488, 1975
  24. Park JB, Kenner KH. Effect of electrical stimulation on tensile strength of the porous implant and bone interface. Biomater Med Devices Artif Organs 3:233-243, 1975
  25. Moriya M, Tanaka H. Experimental study on the application of direct current to the intraosseous implant. J Jpn Prosthodont Soc 34:309-319, 1990
  26. 박상원, 양홍서. 미소전류자극이 TPS-IMZ 임플란트 주위의 골유착과 골형성에 미치는 영향. 대한치과보척학회지 34:722-745, 1996
  27. Roberts WE, Smith RK, Ziberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuous loading of rigid endoosseous implants. Am J Orthod 86:95-102, 1984
  28. Akimoto K, Becker W, Persson R, Baker DA, Rohrer MD, O'Neal RB. Evaluation of titanium implants placed into simulated extraction sockets: A study in dogs. Int J Oral Maxillofac Implants 14:351-360, 1999
  29. Carlsson L, Rostlund T, Albrektsson B, Albrektsson T. Implant fixation improved by close fit; Cylindrical implant-bone interface studied in rabbits. Acta Orthop Scand 59:272-275, 1988
  30. 井上 四郞. 骨 電氣刺軟療法, pp13-45, 1991, 建友館
  31. Kubota K. Effect of electrical currents on alveolar bony defects. Kyushu Dent J 36: 64-81, 1982
  32. Brighton CT, Pollack SR. Treatment of recalcitrant non-union with a capacitively coupled electrical field. J Bone Joint Surg 67-A: 577-585, 1985
  33. Lew D, Marino A. The effect of electrical stimulation on bone formation around hydroxyapatite implants placed on the rabbit mandible. J Oral Maxillofac Surg x49:735-739, 1991
  34. Marino AA. Direct current and bone growth, in Marino AA(ed): Mordern Bioelectricity. New York, NY, Marcel Dekker, 1988, pp657-709, 34
  35. Brighton CT. Treatment of nonunion of tibia with constant direct current. J Trauma 21:189-195, 1981
  36. Dymecki SM, Black J, Brighton CT. The cathodic potential dose-response relationship for medullary osteogenesis with stainless steel electrodes. BRAGS Abstract 4:29, 1984
  37. Karaki R. Experimental study of internal remodeling and callus formation in mandible by electrical stimulation. J Kyushu Dent Soc 32:590-608, 1979
  38. 김영준, 정현주. 3급 치근분지부 골결손에서 미세전류자극이 치주조직의 재생에 미치는 영향에 관한 실험적 연구. 대한치주과학회지 27:845-866, 1997
  39. Johansson C, Albrektsson T. Integration of scew implants in the rabbit: A 1-year follow up removal torque of titanium implants. Int J Oral Maxillifac Implants 2:69-75, 1987
  40. Vangness CT, Carter DR, Frankel VH. In vitro evaluation of loosening characteristics of selftapped and non-self-tapped cortical bone screw. Clin Orthp 157: 279-286, 1981
  41. Morberg P, Albrektsson T. Removal torque for bone-cement and titanium screws implanted in rabbits. Acta Ortho Scand 62:554-556, 1991 https://doi.org/10.3109/17453679108994495
  42. Botticelli D, Berglundh T, Buser D, Lindhe J. The jumping distance revisted Clin Oral Impl Res 14:35-42, 2003
  43. Buser D, Schenk RK, Strinemann S, Fiorelini JP, Fox CH, Stich H. Influenence of surface charactristics on bone integration titanium implants, A histomorphometric study in miniature pigs. J Biomed Mater Res 25:889-902, 1991
  44. Anusavice KJ, Dehoff PH, Fairhurst CW. Comparative evaluation of ceramic metal bond test using finite element stress analysis. J Dent Res 59:608-617, 1980
  45. Weinstein AM, Klavitter JJ, Cleveland TW, Asmos DC. Electrical stimulation of bone growth into porous $Al_{2}O_{3}$. J Biomed Mater Res 10:231-247, 1976