• Title/Summary/Keyword: Blue fluorescence

Search Result 181, Processing Time 0.022 seconds

Mixing Efficiency Evaluation in Y-channel Micromixer Using LIF Confocal Microscope (LIF 공초점 현미경을 이용한 Y-채널 마이크로믹서의 혼합 효율 평가)

  • Kim, Kyoung-Mok;Shin, Yong-Su;Ahn, Yoo-Min;Lee, Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.159-166
    • /
    • 2007
  • Mixing between two or more reagents is one of important processes in biochemical microfluidics. In efficient micromixer design, it is essential to analyze flow pattern and evaluate mixing efficiency with good precision. In this work, mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS) and those are bonded to glass plate through Plasma bonding. Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. For visualization of the flow pattern, dynamic image capturing is carried out using CAM scope. For the comparison with computer simulation, modified SIMPLE algorithm for incompressible flow equation is solved for the same geometry as in the experiment. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.

Photophysical Properties of 1,3-Dimethylnaphtho[1,2-e]uracil

  • Shim, Sang-Chul;Shin, Eun-Ju;Park, Seung-Ki;Kang, Ho-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.196-200
    • /
    • 1986
  • The solvent change and salt do not affect the fluorescence quantum yield of 1,3-dimethylnaphtho[1,2-e]uracil indicating the considerable energy gap between the lowest singlet $({\pi},\;{\pi}^{\ast})\;and\;(n,\;{\pi}^{\ast})$ states in the compound. The results are consistent with the strong quenching of fluorescence by ethyl iodide. Fluorescence quantum yield is nearly independent of temperature, probably due to the relatively inefficient internal conversion. Unusual spectral difference is observed in isopentane and ethanol at 77K. The temperature dependence of emission in isopentane and in ethanol suggests that the increase of charge transfer character by the conformational change in isopentane leads to the structureless and red-shifted fluorescence, while in ethanol the decrease of the charge transfer character by the hydrogen bonding interaction results in the structured and blue-shifted fluorescence along with phosphorescence at the low temperature. Temperature dependence of emission in poly(methylmethacrylate) matrix indicates that $T_1{\to}S_0$ radiationless decay is an important process responsible for the strong temperature dependence of phosphorescence.

Comparison of Clinical Characteristics of Fluorescence in Quantitative Light-Induced Fluorescence Images according to the Maturation Level of Dental Plaque

  • Jung, Eun-Ha;Oh, Hye-Young
    • Journal of dental hygiene science
    • /
    • v.21 no.4
    • /
    • pp.219-226
    • /
    • 2021
  • Background: Proper detection and management of dental plaque are essential for individual oral health. We aimed to evaluate the maturation level of dental plaque using a two-tone disclosing agent and to compare it with the fluorescence of dental plaque on the quantitative light-induced fluorescence (QLF) image to obtain primary data for the development of a new dental plaque scoring system. Methods: Twenty-eight subjects who consented to participate after understanding the purpose of the study were screened. The images of the anterior teeth were obtained using the QLF device. Subsequently, dental plaque was stained with a two-tone disclosing solution and a photograph was obtained with a digital single-lens reflex (DSLR) camera. The staining scores were assigned as follows: 0 for no staining, 1 for pink staining, and 2 for blue staining. The marked points on the DSLR images were selected for RGB color analysis. The relationship between dental plaque maturation and the red/green (R/G) ratio was evaluated using Spearman's rank correlation. Additionally, different red fluorescence values according to dental plaque accumulation were assessed using one-way analysis of variance followed by Scheffe's post-hoc test to identify statistically significant differences between the groups. Results: A comparison of the intensity of red fluorescence according to the maturation of the two-tone stained dental plaque confirmed that R/G ratio was higher in the QLF images with dental plaque maturation (p<0.001). Correlation analysis between the stained dental plaque and the red fluorescence intensity in the QLF image confirmed an excellent positive correlation (p<0.001). Conclusion: A new plaque scoring system can be developed based on the results of the present study. In addition, these study results may also help in dental plaque management in the clinical setting.

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.

Luminescence Properties of Anthracene Chromophores in Cyclosiloxane-Based Hybrid Polymer Films

  • Demirci, Ali;Yamamoto, Shunsuke;Matsui, Jun;Miyashita, Tokuji;Mitsuishi, Masaya
    • Rapid Communication in Photoscience
    • /
    • v.4 no.1
    • /
    • pp.16-18
    • /
    • 2015
  • Luminescence properties of anthracene chromophores were investigated. Anthracene chromophores were incorporated in cyclosiloxane-based hybrid polymers through one-pot hydrosilylation reaction. Using four-armed cyclosiloxanes, divinylterminated siloxane monomers, and 9-vinylanthracenes, anthracene-labeled hybrid polymers were prepared. Free-standing hybrid polymer films were prepared successfully by doctor-blade method and thermal treatment. The polymer films exhibit strong blue fluorescence from anthracene and its fluorescence lifetime was not influenced by the temperature, indicating that the movement of anthracene chromophores was restrained in cyclosiloxane-based hybrid polymer films.

Development of Microfluidic Polydiacetylene Sensor Chip for pH detection (pH 검출을 위한 미세유동 폴리디아세틸렌 센서칩 개발)

  • Hwang, Hyun-Jin;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2415-2418
    • /
    • 2008
  • Polydiacetylenes (PDAs) are very attractive chemical substances which have distinctive features of color change and fluorescence emission by thermal or chemical stress. Especially, when PDAs contact with solutions of a particular pH, such as a strong alkaline sodium hydroxide (NaOH) solution or a strong acidic hydrogen chloride (HCl) solution, PDAs change their color from non-fluorescent blue to fluorescent red. In this study, we propose a novel method to detect alkaline pH using PDAs and NaOH solutions by hydrodynamic focusing on a microfluidic chip. Preliminary results indicate that the fluorescent intensity of PDAs increases in respond to the NaOH solution concentrations. Also, the fluorescence is quenched back when the PDAs are in contact with a HCl solution. These results are useful in a microfluidic PDA sensor chip design for pH detection.

  • PDF

Picosecond Photoionization Processes of N,N,N',N'-Tetramethyl-p-phenylenediamine (TMPD) in Water

  • Lee, Min-Yung;Jang, Du-Jeon;Kim, Dong-Ho;Lee, Sun-Sook;Boo, Bong-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.1
    • /
    • pp.17-20
    • /
    • 1992
  • Photoionization processes of TMPD in $H_2O$ and $D_2O$ were studied, by measuring steady-state absorption, emission, fluorescence excitation spectra, and fluorescence lifetimes on picosecond time scale. The steady-state absorption spectra showed that there exists a cation-ion pair (Wurster's Blue) in $H_2O$ and in $D_2O$ in the electronic ground state. Temperature and excitation wavelength dependence were also studied and the results show that the photoionization reaction in water is an activated process and the fluorescence lifetime is independent of the vibrational excess energy in the uv excitation range of 283-310 nm.

Autofluorescence Loss in Photobleaching for Human Dentin ex vivo

  • Lee, Seunghwan Goldmund;Kim, Minwoo;Jeong, Sunghee;Hwang, Jaejoon;Kim, Jisu;Gourrier, Aurelien;Vial, Jean Claude;Kyhm, Kwangseuk
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.86-91
    • /
    • 2022
  • Two-photon fluorescence microscopy was performed on the enamel-dentin junction area of a human tooth using a femtosecond pulsed laser. We obtained a clear image contrast between the bright dentin and dark tubules with the autofluorescence generated from the endogenous fluorophores in dentin. The autofluorescence shows a broad spectrum due to complex cross links between dentinal collagens, which extend from blue to orange wavelengths (470-590 nm), but a gradual autofluorescence loss in photobleaching was observed for a long-term exposure under strong excitation. For increasing excitation power, we found that two-step decay becomes significant in the spectrally integrated autofluorescence.

Efficient Blue Light Emitting Diode by Using Anthracene Derivative with 3,5-Diphenylphenyl Wings at 9- and 10-Position

  • Kim, Yun-Hi;Lee, Sung-Joong;Jung, Sang-Yun;Byeon, Ki-Nam;Kim, Jeong-Sik;Shin, Sung-Chul;Kwon, Soon-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.443-446
    • /
    • 2007
  • The novel blue light emitting material, 9,10-bis(3',5'-diphenylphenyl)anthracene (BDA) was synthesized by Suzuki coupling reaction and characterized by the measurements of 1H NMR, 13C NMR and FT-IR. The new anthracene derivative, which contains anthracene as a main core unit and 3',5'-diphenylphenyl group derivative as wings, has high fluorescence yield, good thermal stability, and high glass transition temperature at 188 oC. With the newly non-doped blue emitting material in the multilayer device structure, it was possible to achieve the current efficiency of 3.0 cd/A. The EL spectrum of the ITO/CuPc/α-NPD/BDA/Alq3/LiF/Al device showed a maximum wavelength (λmax) at 440 nm. The emitting color of device showed the blue emission (x,y) = (0.18,0.19) at 10 mA/cm2 in CIE (Commission Internationale de l'Eclairage) chromaticity coordinates.

Synthesis of Anthracene Derivative Combined with Cabazole Containing Bulky Substituent (부피가 큰 치환체를 포함하는 카바졸과 결합한 안트라센 화합물의 합성)

  • Ahn, Sang-Won;Yoon, Koo-Young;Lee, Seung-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.160-165
    • /
    • 2013
  • In order to express the natural color in organic light emitting diode(OLED), red, green, and blue luminescent materials are needed. While lots of red and green emitters are searched actively, not many useful blue emitters are found yet. It is due to the high energy gap for the blue emission. This research is about a synthesis of the blue emitting compound with high emission efficiency and thermal stability, which starts with carbazole and anthracene. Carbazole with bulky substituent, tert-butyl group, is connected directly to electroluminescent and thermally stable anthracene. The distance between the hole transporting group and the electron transporting group are studied for the relevance to the luminescence.