• Title/Summary/Keyword: Bi-2223 HTS tape

Search Result 85, Processing Time 0.026 seconds

AC loss Characteristics under Critical Current Degradation of HTS Tapes (고온 초전도 tape의 임계전류 저하에 따른 교류손실 특성)

  • Kim H. J.;Cho J. W.;Kim J. H.;Sim K. D.;Kwag D. S.;Bae J. H.;Kim H. J.;Seong K. S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.29-33
    • /
    • 2005
  • Critical current$(I_c)$ degradation of High $T_c$ Superconducting(HTS) tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the $I_c$ degradation affects the AC loss of the wire. We measured the $I_c$ degradation and AC loss under tension and bending of Bi-2223 tapes made by 'Powder-in-Tube' technique at 77K with self-field. Also, we have studied the frequency characteristics on self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between $I_c$ degradation and AC loss are presented.

Fabrication of 250 m class Bi-2223/Ag HTS Tapes (250 m 급 Bi-2223/Ag 고온 초전도선재 제조)

  • Ha, H.S.;Oh, S.S.;Ha, D.W.;Jang, H.M.;Kim, S.C.;Song, K.J.;Park, C.;Kwon, Y.K.;Ryu, K.S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

Electromagnetic properties of HTS coated conductors fabricated by PLD and MOD (PLD 및 MOD법으로 제조된 2세대 HTS 선재의 전자기 특성)

  • Oh, Sang-Soo;Hwang, Sun-Yuk;Song, Kyu-Jeong;Kang, Suk-Il;Ha, Dong-Woo;Ko, Rock-Kil;Park, Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.65-68
    • /
    • 2004
  • A lot of R&D efforts are being concentrated on the development of high performance HTS coated conductors(CC). Unlike the HTS Bi-2223 tape, a variety of processes have been tried to fabricate CC tapes. PLD and MOD are believed to be very effective methods, and high critical currents of long length CC tape have been reported. In this study, we prepared two kinds of YBCO CCs to evaluate electromagnetic property. One is YBCO tape deposited on IBAD template by PLD and the other is AMSC's MOD CC tape Critical current (Ic) in magnetic fields, its angular dependency, and n-value were measured and analyzed. Magnetic field property of Ic was appeared to be different due the fabrication process. MOD tape showed higher in-field property, n-value of both PLD and MOD tapes exponentially decreased with magnetic field. MOD tape showed higher n-value in whole magnetic fields.

  • PDF

Degradation Behavior of Critical Current in Bi-2223 Superconducting Tape in Bending-Tension Mixed Mode (인장-굽힘모드에서 Bi-2223 초전도 테이프의 임계전류 열화거동)

  • Shin, Hyung-Seop;Kim, Byung-Soo;Choi, Ho-Yeon;Oh, Sang-Soo;Ha, Dong-Woo;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.573-576
    • /
    • 2003
  • HTS superconducting tapes are now commercially available for practical applications such as magnets and cables. Since superconductors in such applications are subjected to high mechanical loads that can significantly degrade the superconducting properties, mechanical properties and the strain tolerance known as the strain effect on superconducting properties are needed to be estimated for developing superconducting devices. Influences of loading mode on the Ic degradation and the interaction on strain effect were discussed in this study.

  • PDF

The effect of cryogenic rolling on critical current density of Bi-2223/Ag HTS tapes (Bi-2223/Ag 고온초전도선재의 Jc와 미세조직에 미는 저온압연의 영향)

  • 최정규;황선역;하동우;오상수;권영길;이세종
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.142-145
    • /
    • 2003
  • In order to investigate the effect of cryogenic rolling on the critical current density (Jc), 54 and 55-multi-filament Bi-2223/hg tapes have been fabricated using a PIT process including two different types of cooling methods. The densification of oxide filament was found to occur due to the cryogenic rolling, and this enhanced the critical current density. However, when the wire was fully immersed in liquid nitrogen used as the coolant in cryogenic rolling, Jc degradation appeared caused by the nitrogen penetration into the filament. The cryogenically rolled tape with an improved type of cooling showed approximately 10% Jc's increase.

  • PDF

Characteristics of Breakdown Current of HTS Tape (고온초전도선의 단선전류 특성분석)

  • Kim, Jae-H.;Sim, K.D.;Cho, J.W.;Kim, H.J.;Seong, K.C.;Kim, H.J.;Gwak, D.S.;Bae, J.H.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.200-202
    • /
    • 2004
  • Characteristics of the break down current of HTS tape with different insulator are described. The various insulators are utilized for enduring the high voltage in superconducting power devices. The break down current of HTS tape largely depends on insulators wound round HTS tape. In this research, The break down currents of Bi-2223 tape, which is widely used for superconducting power devices are tested and discussed. It is expected that results from this study can be utilized as basic data in designing superconducting power devices.

  • PDF

Fabrication and Characteristics of HTS Field Winding of a 100 hp Synchronous Motor (100마력 동기전동기용 고온초전도 계자권선 제작과 특성)

  • Sohn Myung-Hwan;Baik Seung-Kyu;Lee Eon-Young;Kwon Young-Kil;Jo Young-Sik;Moon Tae-Sun;Kim Yeong-Chun;Kwon Woon-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.88-93
    • /
    • 2005
  • To develop a 100 hp high temperature superconducting(HTS) motor with high efficiency first in Korea, we fabricated a HTS field winding and test. HTS field winding is composed of sixteen HTS race track shaped coils wound with stainless steel-reinforced Bi-2223 tape conductor by react and wind fabrication method. Nomex paper was used for electrical insulation. Each of four magnet pole assemblies was constructed with four double pancake sub-coils, mechanically stacked and electrically in series. Four magnet assemblies were fixed on an aluminum support structure to make effective heat transfer. The Critical current (Ic) was 41.5A at 77K and self field. However the lowest Ic value of sub-coils was 35A. Joule heat generated by each joints between sub-coils was lower than 1mW at 77K and 34A. And Joule heat generated by the joints between field coils was lower than 10mW at 77K and 34A. Joule heat of the whole field winding was 1W at 77K and 32A. And so, the lowest Ic value of sub-coils was more important than Joule heats generated by all joints. The operating current must be lower than the lowest Ic of all the sub-coils. In this paper, design, construction and testing of HTS field winding, Joule heat generated by the joints, and operating current were discussed.

Ac Loss Characteristics under Critical Current Degradation of HTS Tapes (고온 초전도체의 임계전류 저하에 따른 교류 손실 특성)

  • Kim, Hae-Joon;Kim, Jae-Ho;Sim, Ki-Deok;Cho, Jeon-Wook;Kwag, Dong-Soon;Kim, Hae-Jong;Seong, Ki-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.286-287
    • /
    • 2005
  • Critical current(Ic) degradation of HTS tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the Ie degradation affects the AC loss of the wire. We measured the Ie degradation and AC loss under tension and bending of Bi-2223 tapes processed by "Powder-in-Tube" technique at 17K with self-field. And we have studied the frequency dependence of self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between Ic degradation and AC loss are presented.

  • PDF

Optimum Design of Multi-Stacking Current Lead Using HTS Tapes (고온초전도 테이프를 이용한 적층형 전류 도입선의 최적설계)

  • 설승윤;김민수;나필선
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The optimum cross-sectional area profile of gas-cooled high-temperature superconductor(HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant satiety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-stacking HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-stacking current leads are discussed.

  • PDF

Optimal Design of Multi-Step Current Leads Using HTS Tapes (고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계)

  • 김민수;나필선;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF