• Title/Summary/Keyword: Bandwidth measurement

Search Result 576, Processing Time 0.027 seconds

A High-speed Atomic Force Microscope for Precision Measurement of Microstructured Surfaces

  • Cui, Yuguo;Arai, Yoshikazu;Asai, Takemi;Ju, BinFeng;Gao, Wei
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.27-32
    • /
    • 2008
  • This paper describes a contact atomic force microscope (AFM) that can be used for high-speed precision measurements of microstructured surfaces. The AFM is composed of an air-bearing X stage, an air-bearing spindle with the axis of rotation in the Z direction, and an AFM probe unit. The traversing distance and maximum speed of the X stage are 300 mm and 400 mm/s, respectively. The spindle has the ability to hold a sample in a vacuum chuck with a maximum diameter of 130 mm and has a maximum rotation speed of 300 rpm. The bandwidth of the AFM probe unit in an open loop control circuit is more than 40 kHz. To achieve precision measurements of microstructured surfaces with slopes, a scanning strategy combining constant height measurements with a slope compensation technique is proposed. In this scanning strategy, the Z direction PZT actuator of the AFM probe unit is employed to compensate for the slope of the sample surface while the microstructures are scanned by the AFM probe at a constant height. The precision of such a scanning strategy is demonstrated by obtaining profile measurements of a microstructure surface at a series of scanning speeds ranging from 0.1 to 20.0 mm/s.

On-chip Magnetic Sensor with Embedded High Inductance Coil for Bio-magnetic Signal Measurement (생체자기 신호측정을 위한 고인덕턴스 코일 내장형 온칩 자기센서)

  • Lyu, HyunJune;Choi, Jun Rim
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.91-98
    • /
    • 2013
  • Magnetic sensor chip for measuring bio-magnetism is implemented in $0.18{\mu}m$ CMOS technology. The magnetic sensor chip consists of a small-sized high inductance coil sensor and an instrumentation amplifier (IA). High inductance coil sensor with suitable sensitivity and bandwidth for measurement of bio-magnetic signal is designed using electromagnetic field simulation. Low gm operational transconductance amplifier (OTA) using transconductance reduction techniques is designed for on-chip solution. Output signal sensitivity of magnetic sensor chip is $3.25fT/{\mu}V$ and reference noise of 21.1fT/${\surd}$Hz. Proposed IA is designed along with band pass filters(BPF) to reduce magnetic signal noise by using current feedback techniques. Proposed IA achieves a common mode rejection ratio of 117.5dB while the input noise referred is kept below $0.87{\mu}V$.

Implementation of Verification and Evaluation Testbed of WiMax2 PKMv2 Encryption Layer (WiMax2 PKMv2 암호화 계층의 검증 및 성능 평가 테스트베드의 구축)

  • Kim, Jang-Hyun;Suh, Hyo-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.77-82
    • /
    • 2013
  • PKMv2 security protocol was adopted by the WiMax2 mobile internet communication standard. A base station and a mobile station protect communication data using key based encryption according to the PKMv2 protocol. Consequently, each development of a base station and/or mobile station includes implement of the PKMv2 protocol, and the station must qualifies various interoperable tests. Furthermore, communication bandwidth of the station can be limited by the encryption module when the station implemented based on a low-performance processor. Thus, a correspondence measurement of the encryption module must be carried on the target processor. In this paper, we implement a testbed which affords throughput measurement as well as the interoperable tests by PKMv2.

Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals (2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정)

  • 정종수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

Spatial Analysis of Cyberspace and Mapping Cyberspace (사이버스페이스의 공간적 분석과 지도화)

  • 이희연
    • Journal of the Korean Geographical Society
    • /
    • v.37 no.3
    • /
    • pp.203-221
    • /
    • 2002
  • This study attempts to analyze the spatial characteristics of cyberspace and to map spatial variations of cyberspace. In order to analyze the spatial distribution of cyberspace, three measurement indices are selected such as commercial domain number, Internet backbone network, and Internet users, which are highly correlated to each other. The three sets of measurement showed that cyberspace in Korea is spreading in a highly uneven fashion, strongly favoring a few cities and unfavoring economically distressed cities. Seoul acts on overwhelmingly dominant role in cyberspace, by being concentrated a number of domains and having high-capacity bandwidth on Internet backbone network. Internet is selectively connecting several cities into highly interactive networks, while at the same time largely bypassing other cities. The development of Internet network through infrastructure investments at selected cities has resulted in an uneven accessibility and digital divide among cities. The regional disparity would be further reinforced by ICT development as the primary vehicle for unequal accessibility. The result of this study revealed that geography continues to matter, despite the recent rhetoric claiming of 'the death of distance'or 'the end of geography'.

A time delay measurement of a chirped fiber grating by using bidirectional modulation of an optical intensity modulator (광변조기의 양방향 변조를 이용한 chirped fiber grating의 시간지연 측정법)

  • Jeon, Geum-Soo;Lee, Yong-Gu;Ban, Jae-Kyung;Heo, Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.510-514
    • /
    • 2002
  • A simple method for a time delay measurement of a chirped fiber grating by using bidirectional modulation of a Mach-Zehnder modulator has been proposed. The bidirectionally modulated light with time difference makes an interference fringe in the RF domain. The time delay of a chirped fiber grating can be obtained by measuring the period of the RF interference fringe for different wavelengths. We have measured the time delay of a chirped fiber grating with a chirped length of 5 cm and a bandwidth of 3.16 nm. The average slope of the time delay has been measured to be 183 ps/nm and its uncertainty has been less than $\pm$1.7%.

Development of a Microwave Radiometer for Remote Sensing of Water Surface Temperature (수면 온도 원격탐사용 마이크로파 라디오미터의 개발)

  • Son, Hong-Min;Youn, Jeong-Beam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1107-1115
    • /
    • 2012
  • This paper presents the development processes of a microwave radiometer for remote sensing of water surface temperature. Achieving the measurement accuracy within $2^{\circ}C$ for water surface temperature of $5{\sim}30^{\circ}C$, the requirements and specifications of the microwave radiometer and its receiver are drawn. The receiver with high gain, high sensitivity is designed and implemented. The receiver has the bandwidth of 50 MHz, the system gain of 45.2 dB and the sensitivity of 0.56K at 5.02 GHz. The effectiveness of the developed microwave radiometer in the measurement of water surface temperature is demonstrated experimentally. The results show the microwave radiometer can detect water surface temperature for $7.5{\sim}18^{\circ}C$ within the accuracy of $0.45^{\circ}C$.

Measurement and Analysis of Electric Filed Distributions under 154[kV] Overhead Tranamission Lines (154[KV] 가공송전선로 아래에서 전장분포의 측정과 분석)

  • 이복희;이정기;안창환;이경옥;박동화;곽희로;송진호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.92-98
    • /
    • 1997
  • In this paper, the results of the measurement and analysis of extremely low freqency(ELF) eletric field in the vicinity of 154[kV] overhad transmission lines have been described. The planar-type electric field sensor has been fabricated by three dimensional structure with special consideration of taking the power frequency and lower components. The calibration experiments have been carried out according to the procedures of IEEE recommendation. The electric field measuring system has the frequency bandwidth of 7[Hz] to 2.7[MHz] and the response sensitivity of 0.094[mV/V/m]. Also the practical measurements of electric field under an 154[kV] double corcuit overhead transmission lines have been made abd abalyzed. It was known that the lateral electric field profiles under an 154[kV] double circuit overhead transmission lines show the asymmetrical distributions owing to the environmental metal frame structures and their maximum electric field magnitude is less than 3[kV/m]. It can be concluded that the measured results of the electric fields satisfy with all limits or guide -lines of the various authorized international institutes' recommendations.

  • PDF

Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers (몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술)

  • Jung, Kwang-Seok;Park, Dae-Won;Cha, Hyeon-Kyu;Cha, Sang-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission (무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작)

  • Kim, Sung-Tae;Cha, Doo-Yeol;Kang, Min-Suck;Cho, Se-Jun;Jang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.