• Title/Summary/Keyword: Anti- Design

Search Result 1,176, Processing Time 0.028 seconds

Quality Evaluation and Mix Proportion of Antiwashout Underwater Concrete with Mineral Admixture (광물질 혼화재료를 사용한 수중불분리성 콘크리트의 배합 및 품질평가 방안 검토)

  • Park, Yong Kyu;Kim, Hyun Woo;Yoon, Ki Woon
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.679-686
    • /
    • 2014
  • In this research, the mix proportion of the antiwashout underwater concrete with the mineral admixture was evaluated. It can reduce the amount used of the antiwashout admixture (hereinafter referred to as "AWA") and satisfy the properties of concrete. In addition, the review for the difference of the test and practical affairs were conducted. Optimized unit quantity of water of antiwashout underwater concrete and the amount used of AWA was revealed by $190kg/m^3$, 0.9%/W, respectively. In particularly, the mix design is reduced by 5% than the W/B of target strength even though the W and AWA reduced. Therefore, it will have the economical feasibility and qualities including the material separation, resistance characteristic and compressive strength, and etc. The stable value was shown in 1 point of minute passed in the measurement of the turbidity amounts using the turbidimeter after the checker insertion. However, it needs to be reviewed for the interrelationship between turbidity measuring machine and KCI-AD102 standard method. There were no significant differences of compressive strength of specimens in the water depending on the production methods.

An Experimental Study and Value Analysis for Performance Assessment of the Embo-thane Membrane Waterproofing Method (엘보탄도막방수공법의 성능평가를 위한실험적 연구 및 VE분석)

  • Yoon, Cha-Woong;Lee, Seung-Soo;Kim, Sang-Rok;Seo, Jong-Won
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.123-134
    • /
    • 2009
  • Since 1970s, urethane waterproofing method is broadly used in rooftops, underground spaces, and sports stadium for its outstanding ultraviolet blockage, watertightness, and elasticity. However, development of slippage-resistance and endurance, improvement of function considering convenience and visually pleasing of users, urethane waterproofing method is necessary, since rooftops and underground spaces have slippage and external force risks. Therefore, many improved waterproofing methods are being developed and, recently, embo-thane waterproofing method, which applies embo-spray coating system, has been developed. This paper explains exposure, nonexposure, and floor-material of embo-thane waterproofing method, and then perform experimental study for comparison with urethane waterproofing method about tensile strength, coefficient of expansion, performance of bond, anti-abrasion, and slippage-resistance. In addition, the performance index was presented for the superiority of embo-thane waterproofing method compared to urethane by setting up evaluation criteria considering not only physical performance but also design side of embo-thane waterproofing method, and Value Analysis applying AHP. Also for an assessment considering uncertain result, Monte Carlo Simulation Method was used to operate reliability analysis through statistic approach method.

A Study on Efficacy of Preemptive Analgesia - A Comparison on Efficacy of Preoperative and Postoperative Analgesic Administration - (선행적 진통 요법의 효과성에 대한 연구 -발치 전과 후 진통 요법의 효과 비교-)

  • Jung, Young-Soo;Kim, Moon-Key;Park, Hyung-Sik;Lee, Eui-Wung;Kang, Jeong-Wan
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.3 no.1 s.4
    • /
    • pp.10-18
    • /
    • 2003
  • Background: Studies on the pain have been dealing with many different ways for last several centuries. Especially, preemptive analgesia is being used as a method to control the postoperative pain. Many studies on its efficacy have been processed in different ways about various drugs, administration methods and times for various operations. And the value of preemptive analgesia are still controversial regarding the results of other clinical studies. The authors performed a clinical study on efficacy of preemptive analgesia using an non-steroidal anti-inflammatory drug (NSAID) for the surgical extraction of impacted third molar teeth and present the more effective pain treatment after oral surgery with literature review. Methods: Using a randomized double blind test design, this study compared the analgesic efficacies of an NSAID, Talniflumate 370 mg. This drug administrated first either 1 hour preoperatively (experimental group) or when the pain developed moderately to severely over 5 scale of verbal rating scales (0-10) to respective 30 patients undergoing the removal of impacted third molars. Pain intensity and the time from the end of surgery were assessed postoperatively whenever the patients demanded additional drug over 5 scale for forty eight hours using same verbal rating scales. Results: The sex distribution, the age of the patients. and the time required for surgery in two groups were similar. The average first time for demanding additional drug after surgery was 163.9 minutes in experimental group and 191.5 minutes in control group. At this time, the average pain intensity was 5.8 in experimental group and 6.1 in control group. And the average second time for demanding additional drug was 365.5 minutes in experimental group and 351.8 minutes in control group. At this time. the average pain intensities were 6.6 in experimental group and 6.2 in control group. No statistically significant difference was found between the average first times and second times, and the average pain intensities at first and second times in two groups. Conclusions: From these results the efficacy of preemptive analgesia used in this study was not appeared. This clinical study indicates that many NSAIDs administrated preoperatively in present practices have weak efficacy of preemptive analgesia for postoperative pain, thus the authors recommend that only postoperative analgesics are adequate without preoperative use of analgesics.

  • PDF

The Effects of Cranio-Sacral Therapy on Brain Function Quotient of Elderly with Long-term Care Insurance Service (두개천골요법이 장기요양시설노인의 뇌기능지수에 미치는 효과)

  • Lee, Jung-eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.474-484
    • /
    • 2016
  • This study was performed to identify the effects of the improvement of brain function by CST on the elderly with the 2nd or 3rd grade of long-term care insurance service. A quasi-experimental design using a nonequivalent control group, pre-post test was used. A total of 12 elders (6 in the experimental group and 6 in the control group) were recruited. Upledger CST(10-Step Protocol) was performed on each subject for 50 minutes per session, once a week, for a total of 8 treatments over an 8 week period from Jan to Feb 2015. The brain function quotient was measured before the 1st CST and after the last CST by portable EEG measurement device using a 2 Channel neuro-feedback system. The data was analyzed by SPSS (Ver. 18.0) program. After CST intervention, the attention quotient (AQ), level of tension, anti-stress quotient (ASQ), emotion quotient (EQ) and brain quotient (BQ) of the experimental group was significantly better than that of the control group. These results showed that the CST was effective in reducing the level of fatigue by the AQ, increasing the physical and psychological stress relief by the ASQ, emotional balance by the EQ, and improving the total brain function by the BQ. Therefore, CST can be used as an effective intervention for improving the health and brain function of the elderly in health facilities.

Acupuncture in Patients with a Vertebral Compression Fracture: A Protocol for a Randomized, Controlled, Pilot Clinical Trial

  • Lee, Hyun-Jong;Seo, Jung-Chul;Park, Sung-Hoon;Kwak, Min-Ah;Shin, Im Hee;Min, Bo-Mi;Cho, Min-Su;Roh, Woon-Seok;Jung, Jin-Yong
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.79-85
    • /
    • 2015
  • Objectives: A vertebral compression fracture (VCF) is characterized by back pain and fracture of a vertebral body on spinal radiography. VCFs of the thoraco lumbar spine are common in the elderly. In general, appropriate analgesics should be prescribed to reduce pain and, thus, promote early mobilization. The ideal treatment approach for VCFs has not been determined. In Korea, acupuncture and herbal medication have been used to treat VCFs for many years. There is empirical evidence that acupuncture might benefit patients with a VCF. However, no randomized, controlled, clinical trials evaluating the efficacy and the safety of acupuncture for treating a VCF have been published. Therefore, we designed a randomized, controlled, pilot, clinical trial to obtain information for the design of a further full scale trial. Methods: A five week protocol for a randomized, controlled, pilot, clinical trial is presented. Fourteen patients will be recruited and randomly allocated to two groups: a control group receiving interlaminar epidural steroid injections once a week for three weeks, and an experimental group receiving interlaminar epidural steroid injections plus acupuncture treatment (three acupuncture sessions per week for three weeks, nine sessions in total). The primary outcomes will be the pain intensity (visual analogue scale and PainVision$^{TM}$ system). The secondary outcome measurements will be the answers on the short form McGill pain questionnaire and the oswestry disability index. Assessments will be made at baseline and at one, three, and five weeks. The last assessment (week five) will take place two weeks after treatment cessation. This study will provide both an indication of feasibility and a clinical foundation for a future large scale trial. The outcomes will provide additional resources for incorporating acupuncture into existing treatments, such as nonsteroidal anti-inflammatory medications, narcotics and vertebral augmentation. This article describes the protocol.

A Study on the End-Uses Performance of Fabrics for Korean Folk Clothes (한복지의 소비성능에 관한 연구)

  • Sung Su-Kwang;Kwon Oh-Kyung;Hwang Ji-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.199-209
    • /
    • 1991
  • In this paper, the fabrics for Korean folk clothes(KFC) undergoes repeated laundering under given condition. After this cyclic laundering was applied, the mechanical properties of the specimen were measured using KES-F system in order to evaluated the end-use performance of fabrics for KFC. And also, the crease recovery of fabrics for KFC were measured by shirley crease recovery tester. 78 different kinds of commercial silk fabrics and polyester fabrics for KFC were used for this study. The experimental results were analysed statistically to relate the mechanical properties and the crease recovery of fabrics for KFC. Furthermore, these changes in dimensional stability, mechanical properties and handle of fabrics for KFC were discussed in comparison with those values for silk fabrics and polyester fabrics. The results obtained are as follows. 1. Regardless of materials, remarkable increase are observed in shrinkage of the fabrics for KFC about repeated laundering, but dull increase are observed in shrinkage after 10 cycles of the repeated laundering. On the other hand, slack extend are observed in dimensions after 20 cycles of the repeated laundering. The shrinkage of fabrics for KFC after 10 cycles of the lundering showed that the silk fabrics are $1.74{\pm}0.33\%$ (warp direction) and $1.35{\pm}0.23\%$ (weft direction) and the polyester fabrics are $1.45{\pm}0.22\%$ (warp direction) and $1.25{\pm}0.23\%$ (weft direction). 2. Except for tensile property, these changes in mechanical properties of fabrics for KFC by laundering have $\pm$ 16 range of bending, shearing, compression, surface, thickness & weight as compared with before laundering. Particularly, the LT and RT about $1\~3$ cycles of the repeated laundering showed remarkable decrease. And SMD, WC, T & W of fabrics for KFC by the laundering were more increased than one for original fabrics. But B, 2HB, G, 2HG, 2HGS were decreased more than one for original fabrics. 3. 'Stiffness', 'Anti-drape', 'Crispness' and 'Scroop' hand values decrease and'Fullness & softness', 'Flexibility & softness' hand values increase with repeated laundering. 4. Remarkable decrease are observed in crease recoveries about $1\~5$ cycles of the repeated lundering, but slack decrease are observed in crease recoveries after 5 cycles of repeated laundering. The crease recovery of fabrics for KFC have negative(-) correlation with LT, RT, G, RC and MMD, This fact implies that the smaller these values, the larger the crease recovery. The crease recovery of fabrics for KFC has a high degree of correlation with the mechanical properties such as shearing, compression, surface property. And also, the crease recovery are expected by measuring the mechanical properties such as G, 2HG, 2HGS, RC, WC, LC, MIU, MMD and SMD, according to the obtained regression equation.

  • PDF

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

Verification of Freezing Index and Frost Penetration Depth with Temperature Data of Korea LTPP (국내 LTPP 온도 자료를 이용한 동결지수와 동결깊이 검증 연구)

  • Kim, Boo-Il;Jeon, Sung-Il;Lee, Moon-Sup;Lim, Kwang-Su
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.143-152
    • /
    • 2009
  • The purpose of this study is to evaluate the freezing index and frost penetration depth. The freezing index and frost penetration depth were analyzed using air temperature and temperature profile of pavement system in Korea LTPP-SPS(Long Term Pavement Performance-Specific Pavement Study) site. The predicted frost penetration depth were then compared with the measured one from the LTPP sites. And the trend of annual freezing index was analyzed using the temperature data of meteorological stations located in the vicinity of Korea LTPP-SPS site. The result showed that the freezing index was rapidly decreased since 1987, and it was known that the use of freezing index determined from the past 30 years temperature data could cause the over estimates in the pavement thickness design. The temperature profile measured at 3 sections of LTPP-SPS sites showed that the temperature of subbase layer was above $0^{\circ}C$, even though anti-frost layers were found in these sections. Comparing the measured and calculated frost depth, the frost depth calculated from the subgrade frost penetration permissible method showed a similar trend with the measured frost depth.

  • PDF

Fabrication of Inductors, Capacitors and LC Hybrid Devices using Oxides Thin Films (산화물 박막을 이용한 인덕터, 캐패시터 및 LC 복합 소자 제조)

  • Kim, Min-Hong;Yeo, Hwan-Guk;Hwang, Gi-Hyeon;Lee, Dae-Hyeong;Kim, In-Tae;Yun, Ui-Jun;Kim, Hyeong-Jun;Park, Sun-Ja
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 1997
  • bliniaturization oi microwave circuit components is an important issue with the development in the mobile communication. Capacitors, inductors anti hybrid devices of these are building blocks of electric circuits, and the fabrication of these devices using thin film technology will influence on the miniaturization of electronic devices In this paper, we report the successful fabrication of the inductors, capacitors and LC hybrid devices using a ferroelectric and a ferromagnetic oxide thin iilm. Au, stable at high temperatures in oxidizing ambient, is patterned by lift-off process, and oxide thin films are deposited by ion beam sputtering and chemical vapor deposition. These devices are characterized by a network analyzer in 0.5-15GtIz range We got the inductance of 5nH, capacitance oi 10, 000 pF and resonant frequencies of $10^{6}-10^{9}Hz$.

  • PDF

Tension Test on the Bar-type Anti-buoyancy Anchors in the Weathered Rock (풍화암에 시공된 Bar Type 부력저항 앵커의 인장 시험)

  • Park, Chan-Duk;Lee, Kyu-Hwan;Ryu, Nam-Jae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.175-181
    • /
    • 2004
  • This study is about a section where underground water level occurs at the underground 5m depth by the excavation of the ground, as a stream is adjacent to a excavation section of High Speed Railway ${\bigcirc}{\bigcirc}$ Station construction sections and a reservoir being always full of water is located at the left side of the construction section. Therefore this test is executed for the design and construction of buoyance anchors able to permanently prevent buoyance by the underground water level at working and for the stable construction and permanent smooth maintenance of structures. In this test, bar type anchors are divided according to their length and standard to execute test-anchor test, and In spot test, 9 test-anchors test, proof test to construction process, suitability test and acceptance test are executed 4 times to 9 test-anchors by dividing anchors according to the length of permanent anchor, the outer diameter of bar and boring diameter. Standard motion characteristic centering on load transmission and break mechanism of bar-type anchors for the prevention of buoyance will be showed in the thesis.