• 제목/요약/키워드: Amorphous ribbon

검색결과 110건 처리시간 0.027초

아몰퍼스 리본의 변위에 의한 자기임피던스 효과 (Magnetic Impeadance Effects by the Displacement of Amorphous Ribbon)

  • 신용진;소대화;김현욱;임재근;강재덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 1999
  • In this thesis, we fabricate a zero-magnetostrictive amorphous ribbon measure the impeadance effect, and then Investigate possibility as a sensor material. $Co_{72.5}$F $e_{0.5}$M $o_{2}$ $B_{15}$ S $i_{5}$ is used as composition of specimen alloy. We first melt the specimen in high frequency induction furnace and then rapidly quench it by using single roll technique. As the result, we obtain a ribbon where thickness is 12${\mu}{\textrm}{m}$, width is 1mm and length is 93mm. Consequently, it is proved through this study that zero-magnetostrictive amorphous ribbon can be used as an excellent magnetic sensor material.rial.l.

  • PDF

무전해 코발트계 석출막에 미치는 기판의 영향 (Effect of Substrate on Electroless Co-Base Deposited Films)

  • 한창석;천창환;한승오
    • 한국재료학회지
    • /
    • 제19권6호
    • /
    • pp.319-324
    • /
    • 2009
  • The deposition behavior and structural and magnetic properties of electroless Co-B and Co-Fe-B deposits, as well as the amorphous ribbon substrates, were investigated. These Co-based alloy deposits exhibited characteristic polycrystalline structures and surface morphology and magnetic properties that were dependent on the type of amorphous substrates. The catalytic activity sequence of the amorphous ribbon electrodes for anodic oxidation of DMAB was estimated from the current density-potential curve in the anodic partial electrolytic bath that did not contain the metal ions. Both the deposition rate and potential in the initial region were obtained in order of the catalytic activity, depending on the alloy compositions of the substrates. The deposition rate linearly varied against the deposition time. The initial deposition potential may have also determined the structural and magnetic properties of the deposit based on the thickness of ${\mu}m$ order. Furthermore, a basic study of the electroless deposition processes on an amorphous ribbon substrate has been carried out in connection with the structural and magnetic properties of the deposits.

Fe-B-Si 비정질 리본의 자기특성에 미치는 응력의 영향 (Stress Effects on Magnetic Properties of Amorphous Fe-B-Si Ribbon)

  • 송재성;김기욱;임호빈
    • 대한전기학회논문지
    • /
    • 제40권5호
    • /
    • pp.496-500
    • /
    • 1991
  • The effects of annealing with and without magnetic field on magnetic properties of amorphous Fe-B-Si cores have been investigated as a function of toroidal stress. By decreasing the toroidal stress, the magnetic properties of the amorphous ribbon have beenimproved. Near 180 domain walls exist in the thermally annealed toroidal cores, but the domain walls exist in the thermally annealed toroidal cores, but the domain walls are not parallel to the longitudinal direction of the ribbon. In the specimen annealed with a magnetic field strength of 10 Oe in the longitudinal ribbon length axis, the domains are nearly parallel to the longitudinal direction due to the field induced uniaxial anisotropy resulting in further increase in the remanent magnetization and decrease in the coercive force and loss.

  • PDF

CoFeSiB 아몰퍼스합금 자기리본 변위센서 개발에 관한 연구 (A Study on Development of the Displacement Sensor of CoFeSiB Amorphous Alloy Magnetic Ribbon)

  • 강재덕;신용진
    • 한국전기전자재료학회논문지
    • /
    • 제14권2호
    • /
    • pp.163-168
    • /
    • 2001
  • This dissertation describes the development of a sensor for measuring microscopic displacement where we use CoFeSiB amorphous alloy magnetic ribbon having near zero magnetostrictive properties. For the development of the sensor, we first fabricate amorphous alloy magnetic ribbon, and then investigate its physical and magnetic properties. Finally, its possibility of practical application as a displacement sensor is discussed. The experimental samples were made of near zero magnetostrictive (Co$\_$0.94/Fe$\_$0.06/)$\_$9/Si$_2$B$\_$19/ alloy which were fabricated by a rapid liquid quenching method. As a results, we got amorphous alloy magnetic ribbons of 12㎛ in thickness, 10 mm in length, and 2.5 m in width. It was found that the crystallization temperature and the Curie temperature are around 451$\^{C}$ and around 441$\^{C}$ respectively. We couldn't observe any noticeable change of the impedance frequency of 10MHz, but observed the impedance change of 3.76 %/Oe at 100 MHz. The inductance was nearly stable over the frequency range of 1∼10 MHz, In addition, it was observed that the variation of the inductance and the impedance were linear within the displacement ranges of 20∼60㎛. As the results of the experiments, it is suggested that the displacement sensor which is fabricated by using amorphous alloy magnetic ribbon of (Co$\_$0.04/Fe$\_$0.06/)$\_$79/Si$_2$B$\_$19/ compound, can be used as a sensor to detect microscopic displacement.

  • PDF

Prototype Milli Gauss Meter Using Giant Magnetoimpedance Effect in Self Biased Amorphous Ribbon

  • Kollu, Pratap;Yoon, Seok-Soo;Kim, Gun-Woo;Angani, C.S.;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.194-198
    • /
    • 2010
  • In our present work, we developed a GMI (giant magnetoimpedance) sensor system to detect magnetic fields in the milli gauss range based on the asymmetric magnetoimpedance (AGMI) effect in Co-based amorphous ribbon with self bias field produced by field-annealing in open air. The system comprises magnetoimpedance sensor probe, signal conditioning circuits, A/D converter, USB controller, notebook computer, and program for measurement and display. Sensor probe was constructed by wire-bonding the cobalt based amorphous ribbon with dimensions $10\;mm\;{\times}\;1\;mm\;{\times}\;20\;{\mu}m$ on a printed circuit board. Negative feedback was used to remove the hysteresis and temperature dependence and to increase the linearity of the system. Sensitivity of the milli gauss meter was 0.3 V/Oe and the magnetic field resolution and environmental noise level were less than 0.01 Oe and 2 mOe, respectively, in an unshielded room.

Spatial Distributions of Alloying Elements Obtained from Atom Probe Tomography of the Amorphous Ribbon Fe75C11Si2B8Cr4

  • Shin, Jinkyung;Yi, Seonghoon;Pradeep, Konda Gokuldoss;Choi, Pyuck-Pa;Raabe, Dierk
    • 한국재료학회지
    • /
    • 제23권3호
    • /
    • pp.190-193
    • /
    • 2013
  • Spatial distributions of alloying elements of an Fe-based amorphous ribbon with a nominal composition of $Fe_{75}C_{11}Si_2B_8Cr_4$ were analyzed through the atom probe tomography method. The amorphous ribbon was prepared through the melt spinning method. The macroscopic amorphous natures were confirmed using an X-ray diffractometer (XRD) and a differential scanning calorimeter (DSC). Atom Probe (Cameca LEAP 3000X HR) analyses were carried out in pulsed voltage mode at a specimen base temperature of about 60 K, a pulse to base voltage ratio of 15 %, and a pulse frequency of 200 kHz. The target detection rate was set to 5 ions per 1000 pulses. Based on a statistical analyses of the data obtained from the volume of $59{\times}59{\times}33nm^3$, homogeneous distributions of alloying elements in nano-scales were concluded. Even with high carbon and strong carbide forming element contents, nano-scale segregation zones of alloying elements were not detected within the Fe-based amorphous ribbon. However, the existence of small sub-nanometer scale clusters due to short range ordering cannot be completely excluded.

교류자기저항효과를 이용한 비정질 리본 전류센서 (Current sensor application of giant magnetoimpedance in amorphous materials)

  • 임영우;김철기;김종오;김기덕;박영태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 초전도 자성체
    • /
    • pp.11-13
    • /
    • 2002
  • The performance of DC current sensor based on giant magnetoimpedance (GMI) effect in amorphous ribbon has been tested. The ribbon after field annealing shows the maximum GMI ratio of 30 % at 100 kHz measuring frequency. In the sensor element of sample wound the circular form, GMI ratio and sensitivity are decreased due to internal stress. The sensor voltage output increases with applied DC current up to 1 A with a good linearity, of which direction can be known due to asymmetric characteristics.

  • PDF

CoFeSiB 아몰퍼스리본의 열처리에 의한 대바크하우젠 효과 (Large Barkhausen Effects by Annealing of CoFeSiB Amorphous Ribbon)

  • 임재근;강재덕;정병두;신용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.59-72
    • /
    • 1999
  • In this thesis, we measured the Barkhausen effect of CoFeSiB amorphous ribbon and then investigated its possibility to be used as a sensor material. We used a sample of composition $($Fe_{0.06}$$Co_{0.94}$)_${0.79}$$Si_{2.1}$$B_{18.9}$ with a thickness 12[pm1, width 2.5[rnml and length 5[cm], which was fabricated by a single roll method. In order to improve magnetic characteristics of the sample, we had carried on annealing in the magnetic field and in none magnetic field. And, experimented results to the magnetic characteristics show that the ribbon has large Barkhausen jump even in weak magnetic field below 0.5[0el. From the results, we confirmed that the sample can be used as an magnetic sensor material.

  • PDF

Pd 코팅된 Zr기 비정질 합금의 수소취성 및 표면특성 (Hydrogen Embrittlement and Surface Properties of Pd-coated Zr-based Amorphous Alloys)

  • 석송;이덕영;김기배
    • 한국수소및신에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.182-188
    • /
    • 2007
  • [ $Zr_{50}-Ni_{27}-Nb_{18}-Co_5$ ] amorphous alloys ribbon was prepared by a single-roller melt-spinning technique. In order to improve the hydrogen kinetics Pd-coating were carried out on each side of the amorphous ribbon. Pd prevents oxidation of Zr and catalyses the dissociation of molecular hydrogen to atomic hydrogen. In this work, the hydrogen embrittlement and surface properties on Zr-based amorphous alloys were investigated. The Zr-based amorphous alloys were characterized by X-ray diffractometry(XRD) and differential scanning calorimetry(DSC). The morphology of surface and roughness was observed by using scanning electron microscopy(SEM) and atomic force microscopy (AFM). A lattice parameter of both Pd and Zr-based amorphous alloy was increased after hydrogen permeation at 473 K. After hydrogen permeation at 473 K, some cracks were observed on the surface of Pd, which was the cause for the hydrogen embrittlement. The crystallization temperature of Zr-based amorphous alloy was decreased due to the permeated hydrogen.

졸-겔 법에 의해 절연코팅된 철계 비정질 리본의 자기특성 (Magnetic properties of Fe-based amorphous ribbon insulated by sol-gel process)

  • 송재성;김병걸;정순종;김현식ㅂ;황시돌
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권2호
    • /
    • pp.159-164
    • /
    • 1996
  • The development of an insulated coating which can be used for amorphous alloys is extremely important from the practical point of view. This importance may be enhanced by the influence of the coating on the magnetic properties. The purpose of this study is to show how new developed insulating coating materials and method influence the magnetic properties of amorphous Fe/sub 87/Zr/sub 7/B/sub 5/Ag/sub 1/(at%) ribbon.

  • PDF