Performance Test of a Small Simulated High-Altitude Test Facility for a Gas-turbine Combustor (가스터빈 저온/저압 점화장치 구성 및 운영조건 확인 시험)

  • Kim, Tae-Woan;Lee, Yang-Suk;Ko, Young-Sung;Lim, Byeung-Jun;Kim, Hyeong-Mo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.153-156
    • /
    • 2008
  • Ignition and combustion performance of a gas-turbine engine were changed by various high-altitude condition. A goal of this study is to make the small test facility to simulate high-altitude condition. To perform the low pressure condition, a diffuser was used in various diffuser front of primary nozzle pressure. To perform the low temperature, heat exchanger was used in various mixture ratio of cryogenic air and ambient temperature air. The experimental result shows that high-altitude conditions can be controled by diffuser front of primary nozzle pressure and mixture ratio of cryogenic air and ambient temperature air.

  • PDF

Greenhouse Gas (CH4, CO2, N2O) Emissions from Estuarine Tidal and Wetland and Their Characteristics (온실기체 (CH4, CO2, N2O)의 하구언갯벌 배출량과 배출특성연구)

  • Kim, Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.225-241
    • /
    • 2007
  • A closed flux chamber system was used for measuring major greenhouse gas (GHG) emission from tideland and/or wetland soils in estuarine area at Saemankum, Kunsan in southwestern Korea during from months of February to June 2006. Hourly averaged GHG soil emissions were measured two to three times a day during the ebb tide hours only. Site soils were analyzed for soil parameters (temperature, pH, total organic contents, N and C contents in soil) in the laboratory. Soil GHG fluxes were calculated based on the GHG concentration rate of change measured inside a closed chamber The analysis of GHG was conducted by using a Gas Chromatography (equipped with ECD/FID) at laboratory. Changes of daily, monthly GHGs' fluxes were examined. The relationships between the GHG emissions and soil chemical contents were also scrutinized with respect to gas production and consumption mechanism in the soil. Soil pH was pH $7.47{\pm}0.49$ in average over the experimental period. Organic matter contents in sample soil was $6.64{\pm}4.98\;g/kg$, and it shows relatively lower contents than those in agricultural soils in Kunsan area. Resulting from the soil chemistry data, soil nitrogen contents seem to affect GHG emission from the tidal land surface. The tidal soil was found to be either source or sink for the major GHG during the experimental periods. The annual average of $CH_{4}\;and\;CO_{2}$ fluxes were $0.13{\pm}0.86\;mg\;m^{-2}h^{-1}\;and\;5.83{\pm}138.73\;mg\;m^{-2}h^{-1}$, respectively, which will be as a source of these gases. However, $N_{2}O$ emission showed in negative flux, and the value was $-0.02{\pm}0.66\;mg\;m^{-2}h^{-1}$, and it implies tidal land surface act as a sink of $N_{2}O$. Over the experimental period, the absolute values of gas fluxes increased with soil temperature in general. Averages of the ambient gas concentration were $86.8{\pm}6.\;ppm$ in $CO_{2},\;1.63{\pm}0.34\;ppm\;in\;CH_{4},\;and\;0.59{\pm}0.15\;ppm\;in\;N_{2}O$, respectively. Generally, under the presence of gas emission from agricultural soils, decrease of gas emission will be observed as increase in ambient gas concentration. We, however, could not found significant correlation between the ambient concentrations and their emissions over the experimental period. There was no GHG compensation points existed in tide flat soil.

Hydrogen Sensing of Graphene-based Chemoresistive Gas Sensor Enabled by Surface Decoration

  • Eom, Tae Hoon;Kim, Taehoon;Jang, Ho Won
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.382-387
    • /
    • 2020
  • Hydrogen (H2) is considered as a new clean energy resource for replacing petroleum because it produces only H2O after the combustion process. However, owing to its explosive nature, it is extremely important to detect H2 gas in the ambient atmosphere. This has triggered the development of H2 gas sensors. 2-dimensional (2D) graphene has emerged as one of the most promising candidates for chemical sensors in various industries. In particular, graphene exhibits outstanding potential in chemoresistive gas sensors for the detection of diverse harmful gases and the control of indoor air quality. Graphene-based chemoresistive gas sensors have attracted tremendous attention owing to their promising properties such as room temperature operation, effective gas adsorption, and high flexibility and transparency. Pristine graphene exhibits good sensitivity to NO2 gas at room temperature and relatively low sensitivity to H2 gas. Thus, research to control the selectivity of graphene gas sensors and improve the sensitivity to H2 gas has been performed. Noble metal decoration and metal oxide decoration on the surface of graphene are the most favored approaches for effectively controlling the selectivity of graphene gas sensors. Herein, we introduce several strategies that enhance the sensitivity of graphene gas sensors to H2 gas.

H$_2$ Gas Sensing Properties of Pt/MoO$_3$ Gas Sensor (Pt/MoO$_3$가스센서의 수소 감지 특성)

  • 최용일;김창교;김진걸;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.118-122
    • /
    • 1996
  • 1wt% Pt/MoO$_3$ gas sensors for detecting H$_2$ gas were fabricated by the pressed pellet method and surface structures of Pt/MoO$_2$ were investigated by TEM and XRD. It was observed that as the calcination temperature is increased, the overlayers of MoO$_3$ on Pt are produced, but the Cl content in PtCl$\_$x/ are decreased. H$_2$ gas sensing properties in N$_2$ ambient and in air ambient were investigated, respectively, and Pt/MoO$_3$ had high sensitivity at low working temp ; 7.8% at 50$^{\circ}C$, 97.7% at 100$^{\circ}C$, 97.1% at 150$^{\circ}C$ when the specimens are treated at 400$^{\circ}C$, and 99.6% at 150$^{\circ}C$ when they are treated at 200$^{\circ}C$. It shows the development of a low-power type sensor is possible by using Pt/MoO$_3$.

  • PDF

Heterogeneous Ignition of $H_2/O_2/CO_2$ Mixture Over Platinum Catalyst (수소/산소/이산화탄소 혼합기의 백금촉매반응특성 : 비균일 반응의 점화 온도)

  • Nam, Chang-Ho;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.90-96
    • /
    • 2001
  • Catalytic ignition of $H_2/O_2/CO_2$ mixtures over platinum catalyst is experimentally investigated by using microcalorimetry. For comparison, $N_2$ and Ar is also used as diluent gas. The gas mixture flows toward platinum foil heated by electric current at atmosphere pressure and ambient temperature. The ignition temperature range 350-445K according to the fuel ratio, dilution ratio and diluent gas. It increases as the fuel ratio and dilution ratio increase. $H_2/O_2$ mixture with $CO_2$ ignites at higher temperature than with other diluents by 30-50K. Several experimental evidences show the inhibition effects of $CO_2$ in $H_2-O_2$ heterogeneous reaction is considerable

  • PDF

Operating Characteristics Study of a Small Gas/Steam Turbine Combined System Using Biogas (바이오가스 연료를 사용하는 소형 가스/증기터빈 복합 발전 시스템의 성능특성 해석)

  • Kang, Do-Won;Shin, Hyun-Dong;Kim, Tong-Seop;Hur, Kwang-Beom;Park, Jung-Keuk
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2012
  • This study analyzed the influence of firing biogas on the performance and operation of a gas/steam turbine combined system. A reference gas/steam turbine combined system, designed with biogas fuel(57% volumetric methane) was set up and off-design simulation was made to investigate operating characteristics when a couple of operating schemes to mitigate turbine blade overheating were applied. Performance at base-load operation using each scheme was compared and part load operation using the variable inlet guide vane was analysed. Also, differences in operating characteristics and performance caused by changes in the methane content of biogas and ambient temperature were examined.

EFFECT OF DI-TERTIARY-BUTYL PEROXIDE ON IGNITION PERFORMANCE IN A COMPRESSION IGNITION NATURAL GAS ENGINE

  • Li, F.C.;Zheng, Q.P.;Zhang, H.M.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.413-419
    • /
    • 2007
  • Experimental study of additives on the ignition performance of a compression ignition natural gas engine is introduced, followed by results of a simulation of its working mechanism. From the experimental results, it is understood that engine ignition performance can be improved when a certain amount of Di-tertiary-butyl peroxide additive is added. If the mass fraction of Di-tertiary-butyl peroxide additive reaches as high as 14.2%, engine ignition can be realized at ambient temperatures with a glow plug temperature of about $750^{\circ}C$. From the simulation results, we verify that the Di-tertiary-butyl peroxide additive, by cracking its radicals at lower temperature, can accelerate reaction rate. Therefore, the additive is able to improve the ignition performance of natural gas significantly.

A Study of the Behavior of Liquid Phase Spray Considering Critical Condition of the Fuel (연료의 임계조건을 고려한 디젤 액상분무거동에 관한 연구)

  • Park, Jong-Sang;Kim, Si-Pom;Chung, Sung-Sik;Ha, Jong-Yul;Yeom, Jeong-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.467-472
    • /
    • 2007
  • In this study the penetration distance of liquid phase fuel(i.e. liquid phsae length) was investigated in evaporative field. An exciplex fluorescence method was applied to the evaporative fuel spray to measure and investigate both the liquid and the vapor phase of the injected spray. For accurate investigation, images of the liquid and vapor phase regions were recorded using a 35mm still camera and CCD camera, respectively. Liquid fuel was injected from a single-hole nozzle (l/d=1.0mm/0.2mm) into a constant-volume chamber under high pressure and temperature in order to visualize the spray phenomena. Experimental results indicate that the liquid phase length decreased down to a certain constant value in accordance with increase in the ambient gas density and temperature. The constant value, about 40mm in this study the, is reached when the ambient density and temperature of the used fuel exceed critical condition.

Improvement of Gas Turbine Performance Using LNG Cold Energy (액화천연가스의 냉열을 이용한 가스터빈의 성능향상)

  • Kim, Tong Seop;Ro, Sung Tack;Lee, Woo Il;Choi, Mansoo;Kauh, Sang Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

Prediction of Maximum Liquid-phase Penetration in Diesel Spray: A review

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.117-125
    • /
    • 2008
  • The correlations for the prediction of maximum liquid-phase penetration in diesel spray are reviewed in this study. The existing models developed for the prediction of maximum liquid-phase penetration can be categorized as the zero-dimensional (empirical) model, the multi-dimensional model and the other model. The existing zero-dimensional model can be classified into four groups and the existing multidimensional models can be classified into three groups. The other model includes holistic hydraulic and spray model. The maximum liquid-phase penetration is mainly affected by nozzle diameter, fuel volatility, injection pressure, ambient gas pressure, ambient gas density and fuel temperature. In the case of empirical correlations incorporated with spray angle, the predicted results will be different according to the selection of correlation for spray angle. The research for the effect of boiling point temperatures on maximum liquid-phase penetration is required. In the case of multidimensional model, there exist problems of the grid and spray sub-models dependency effects.

  • PDF