• Title/Summary/Keyword: All-ceramic materials

Search Result 514, Processing Time 0.024 seconds

Comparison of marginal gap of monolithic CAD/CAM-generated crowns according to the ceramic materials for CEREC system (CEREC system에서 사용하는 세라믹 소재로 가공된 CAD/CAM 전부도재관의 변연간격 비교분석)

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.119-125
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the marginal gap of all-ceramic crowns fabricated by CEREC$^{(R)}$ in-office CAD/CAM system. Methods: The mandibular first molar was selected as the abutment for the experiments. Thirty working models were prepared. VITA Mark II(VM) and VITA Enamic(VE), LAVA Ultimate(LU) blocks were milled using CEREC MCXL with CEREC 3D system to construct 10 crowns for each groups. To measure marginal gap, milled restorations were examined under digital microscope with scale under 160x magnifications. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There was no significant difference in the marginal gap regarding to ceramic materials(p>0.05). Conclusion: Single crowns fabricated using CEREC in-office CAD/CAM system provided clinically acceptable marginal gap. This confirmed that the type of ceramic material used does not determine the precision of fit of a prosthesis.

Effects of Titania Whisker Precipitation on Wear Property of the Glass-Ceramic (타이타니아 단섬유상의 석출이 결정화유리의 마모특성에 미치는 영향)

  • 이경호
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.2
    • /
    • pp.192-202
    • /
    • 1996
  • In Li0.4Ca0.05AlP0.5Si0.75O4.5 composition glass, glass-ceramic having a near 100% crystallinity after nucleation heat treatment of 74$0^{\circ}C$/2 h and crystallization heat treatment of 90$0^{\circ}C$/2 h and in-situ TiO2 whisker reinforced glass-ceramic after heat treatment of 105$0^{\circ}C$ for 20 h were fabricated with the addition of 4% TiO2 as a nucleating agent. With these materials a ball-on-disc type wear test was conducted in order to examine the effect of TiO2 whisker prepcipitation on ambient and high temperature wear properties of the glass-ceramic. Wear test results indicated that all specimens exhibited micro-fracture wear mechanism in ambient temperature. As temperature increased the wear rates of the materials were increased. However the in-situ TiO2 whisker reinforced glass-ceramic exhibited the lowest wear rate over the test temperature range. This resulted from the improvement of harness and fracture toughness of the material as the glass converted into the glass-ceramic followed by precipitation of TiO2 whiskers throughout the glass-ceramic matrix.

  • PDF

Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

  • Suputtamongkol, Kallaya;Tulapornchai, Chantana;Mamani, Jatuphol;Kamchatphai, Wannaporn;Thongpun, Noparat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.319-325
    • /
    • 2013
  • PURPOSE. The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS. Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at ${\alpha}$=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS. $L^*$, $a^*$, and $b^*$ values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ${\Delta}E{^*}_{ab}$ values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION. No significant differences were observed between the $L^*$, $a^*$, and $b^*$ values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ${\Delta}E{^*}_{ab}$ values.

A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS (구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구)

  • Kang Han-Joong;Dong Jin-Keun;Oh Sang-Chun;Lee Hae-Hyoung;Song Ki-Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

Mo-Mn Metallizing on Sintered Alumina and It합s Bond Strength (소결 알루미나의 금속접합 및 접합강도에 관한 연구)

  • Lee, Joon;Kim, Young-Tai;Jang, Sung-Do;Son, Yong-Bae
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.6
    • /
    • pp.58-70
    • /
    • 1985
  • The bond strength of metal to ceramic sealing in Mo-Mn metallizing was investigated by examining the effects of flux composition in alumina ceramics particle size of molybdenum metal powder wet hydrogen atmosphere and temperature in metallizing. The maximum bond strength was obtained when the glass phase filled almost all the microstructural cavities around the interfacial area with few micropores. Such a favorable microstrcutre waas formed and maximum bond strength was observed between 130$0^{\circ}C$. Also the metal to ceramic bond strength was increased using finer molybdenum metal powder than coarse powder. When content of $SiO_2$ in the flux of alumina ceramics was constant metal to ceramic bond strength was improved with increasing the ratio of CaO to MgO in the flux.

  • PDF

Solid State Sintering of Calcium Phosphate Ceramic Composites and Their Cellular Response

  • Cho, Yeong-Cheol;Kong, Young-Min;Riu, Doh-Hyung
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.9
    • /
    • pp.691-695
    • /
    • 2012
  • Calcium phosphate ceramic composites, consisting of hydroxyapatite(HA) and tricalcium phosphate (TCP), were fabricated by solid state sintering in order to investigate the effect of their initial compositions on microstructural evolutions and biocompatibility. All the sintered calcium phosphate ceramics exhibited almost full densification, while the grain growth of the composites increased with an increasing TCP content in the green body. The TCP phase transformed into a Ca-deficient HA phase during sintering via the diffusion of calcium ions from the HA phase into the TCP phase. The phases formed in the composites significantly affected the biocompatibility of the composites. The HA-matrix ceramic composites with TCP had a better cellular response than the pure HA ceramics, presumably due to the newly formed Ca-deficient HA.

Preparation of p-type transparent conducting $CuGaO_2$ thin film by DC/RF sputtering (DC-RF 스퍼터링에 의한 p형 투명 전도성 $CuGaO_2$ 박막의 제조)

  • Park, Hyun-Jun;Kwak, Chang-Gon;Kim, Sei-Ki;Ji, Mi-Jung;Lee, Mi-Jae;Choi, Byung-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.48-48
    • /
    • 2007
  • P-type transparent conducting $CuGaO_2$ thin films have been prepared by DC/RF sputtering using Quartz(0001) and sapphire(0001) substrates. The target was fabricated by heating a stoichiometric mixture of CuO and $Ga_2O_3$ at 1373K for 12h under $N_2$ atmosphere. The film were deposited under mixture gas of Ar and $O_2(Ar:O_2=4:1)$ during 10~30min. and the as-deposited films were annealed at 1123K and $N_2$ atmosphere. Room temperature conductivity and the activation energy of the sintered body in the temperature range of 223K ~ 423K were 0 004S/cm, 1.9eV, respectively. XRD revealed that all of the as-deposited films were amorphous. Heating of the films deposited on Quartz substrates above 1123K resulted in crystallization with a second phase of $CuSiO_3$, which was assumed owing to reaction with Quartz substrate. The single phase of $CuGaO_2$ was obtained at the film deposited on the sapphire substrates. The transmittance after annealing of DC- and RF-sputtered films were 55~75% at 550nm. From the transmittance and reflectance measurement. the direct band gap of the DC/RF-sputtered films were 3.63eV and 3.57eV. and there was little difference between DC and RF sputtered films.

  • PDF

Growth of Gallium Oxide Thin Film on c-, a-, m-, r-Plane Sapphire Substrates Using Mist Chemical Vapor Deposition System (미스트 화학기상증착법을 이용한 c면, a면, m면, r면 사파이어 기판 위의 산화갈륨 박막 성장 연구 )

  • Gi-Ryeo Seong;Seong-Ho Cho;Kyoung-Ho Kim;Yun-Ji Shin;Seong-Min Jeong;Tae-Gyu Kim;Si-Young Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.74-80
    • /
    • 2023
  • Gallium oxide (Ga2O3) thin films were grown on c-, a-, m-, r-plane sapphire substrates using a mist chemical vapor deposition system. Various growth temperature range of 400~600℃ was applied for Ga2O3 thin film deposition. Then, several structural properties were characterized such as film thickness, crystal phase, lattice orientation, surface roughness, and optical bandgap. Under the certain growth temperature of 500℃, all grown Ga2O3 featured rhombohedral crystal structures and well-aligned preferred orientation to sapphire substrate. The films grown on c-and r-plane sapphire substrates, showed low surface roughness and large optical bandgap compared to those on a-and m-plane substrates. Therefore, various sapphire orientation can be potentially applicable for future Ga2O3-based electronics applications.

Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns

  • Choi, Jae-Won;Bae, Ik-Hyun;Noh, Tae-Hwan;Ju, Sung-Won;Lee, Tae-Kyoung;Ahn, Jin-Soo;Jeong, Tae-Sung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2016
  • PURPOSE. This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS. There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey's test (P<.05). RESULTS. The Leucite group ($2.670{\pm}1.471mm^3$) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium ($2.042{\pm}0.696mm^3$), Zirconia ($1.426{\pm}0.477mm^3$), and Steel groups ($0.397{\pm}0.192mm^3$). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05). CONCLUSION. Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia.

Optical Properties according to BaO Addition for BaO-GeO2-La2O3-ZnO System (BaO-GeO2-La2O3-ZnO 계에 있어서 BaO 첨가량 변화에 따른 광학 특성)

  • Cho, Jaeyoung;Kim, Jinho;Kim, Sae-Hoon;Lee, Mijai
    • Korean Journal of Materials Research
    • /
    • v.32 no.9
    • /
    • pp.379-383
    • /
    • 2022
  • In this study, Barium Germanium glasses were prepared with a composition of xBaO-(72-x)GeO2-8La2O3-20ZnO where x = 16.0, 18.0, 20.0, 22.0 and 24.0 mol% respectively. Their physical and optical properties, such as refractiveness index, glass transition temperature (Tg), softening temperature (Ts), transmittance and Knoop hardness were studied. The results showed that refractive index, Tg, Ts and coefficient of thermal expansion (CTE) increased with increasing BaO concentration. The refractive index of all the prepared samples was observed between 1.7811 to 1.7881. The Abbe number was calculated by formula using nd (589.3 nm), nf (656.3 nm) and nc (486.1 nm) and observed to be between 38 to 40. The Abbe number of the prepared sample was similar to that of BaO and GeO2. The transmittance of the prepared glasses was observed to be between 80 ~ 82 % throughout the range from 200 nm to 800 nm. Knoop hardness divided into seven steps were measured 5 class (≥ 450 ~ < 550) of all prepared samples.