• Title/Summary/Keyword: All-bond 2

Search Result 793, Processing Time 0.031 seconds

THE EFFECTS OF METAL SURFACE TREATMENTS ON THE BONE STRENGTH OF POLYMETHYL METHACRYLATE BONDED REMOVABLE PROSTHESE (가철성 보철물의 금속면 처리방법이 열중합 레진과 금속간의 결합강도에 미치는 영향)

  • Eom, Tae-Wan;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.336-354
    • /
    • 1998
  • Traditionally, many kinds of mechanical bonding techniques were used for bonding resins to the surface of the metal alloys. If there is a seperation between resin and metal junction by stress accumulation and temperature change of oral cavity, the cracks or crazing may occur, accompanied by failure of resin bonding to metal. This study was designed to compare the shear bond strength of the type IV gold alloy and Cr-Co alloy surfaces treated with various methods and thermocycling. Universal Instron (Model 1000) and scanning electron microscope (JEOL, Japan) was used to record the shear bond strength of 5 groups. Forty specimens were made for each group ; group 1 was treated with sandblasting only, group 2 was coated with V-primer after sandblasting, group 3 was coated with Metal primer, group 4 wase coated with MR Bond and group 5 was coated with silane. After treated with various methods, thermocycling was done for half of the each group. The surfaces of failed pattern were observed with SEM. The results were as follows : 1. Shear bond strength of the group 1 was lower than that of another groups in type IV gold alloys and bond strength of the group 1, 2 were lower than that of group 3, 4, 5 in Cr-Co alloys. 2. Shear bond strength of the gold alloy with resin was higher than that of Cr-Co alloy when specimens were coated with V-primer. 3. Shear bond strength of the Co-Cr alloys with resin was higher than that of gold alloys when specimens were coated with Metal primer. 4. The bond strength of all specimens did not decreased significantly after thermocycling. 5. Adhesive failures were found in group 1 and Cr-Co alloy in group 2, but adhesive and cohesive failures were found in another groups.

  • PDF

A STUDY ON THE REDUCTION OF GALVANIC CURRENT BETWEEN AMALGAM AND GOLD ALLOY WITH VARIOUS CHEMICAL AGENTS (수종 아말감과 금합금의 갈바닉 전류 측정에 관한 연구)

  • Kim, Seung-Soo;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.469-481
    • /
    • 1993
  • The purpose of this study was to achieve the reduction of the galvanic current between the dental amalgam alloy and gold alloy. In order to measure the galvanic current between these two metals a prep in the size of $4{\times}13mm$ which was filled with amalgam and another prep of $4{\times}2mm$ was filled with gold alloy was made in the acrylic resin. These two preps were then connected to a 2mm diameter copper wire. Using an ammeter to measure the galvanic current, six different kinds of amalgam and gold alloy were immersed in saline solution with approximately 10mm distance between the two alloys. Chemical agents that are thought to reduce the galvanic current such as hydrazine. silver nitrate, potassium chromate, and bonding agents such as Scotch bond 2(3M) and All bond 2(Bisco) were applied to the alloy surface. Cathodic inhibitor such as hydrazine was applied to gold alloy where as anodic inhibitor such as silver nitrate and potassium chromate were applied to amalgam. Both bonding agents, Scotch bond 2(3M) and All bond 2 (Bisco), were applied to amalgam. The following results were obtained when the currency on the coated alloy surface was compared to the uncoated surface. 1. The galvanic currency went down as the time elapsed and after 30 minutes no change was detected. 2. Initial currency was higher in low copper amalgam compared to high copper amalgam. Intitial currency was the highest in low copper lathe-cut amalgam. 3. Group of gold coated with hydrazine had the most reduction in galvanic currency. 4. Group of amalgam coated with silver nitrate or potassium chromate also showed significant reduction in galvanic currency. 5. The bonding agents also helped reduce galvanic currency. 6. Of all the agents used to reduce galvanic currency, silver nitrate showed the best result.

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN TO GLASS IONOMER CEMENT ACCORDING TO SURFACE TREATMENT METHODS OF GLASS IONOMER CEMENT (글라스 아이오노머 시멘트의 표면처리방법에 따른 복합레진과의 전단결합강도에 관한 연구)

  • No, Bong-Hwan;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.362-371
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength between composite resin and glass ionomer cement according to surface treatment methods of glass ionomer cement. Sixty round acrylic cylinders were fabricated. And then, a round undercut cavity(8 mm diameter, 2.5mm depth) was prepared in the center of the every acrylic cylinder. After all cavities were restored by using light-cured glass ionomer cement. A total of sixty acrylic cylinders restored with glass ionomer cement were divided into 4 groups according to surface treatment methods of glass ionomer cement. The surface treatment of each group were as follows : control group : no treatment Group 1 : acid etching Group 2 : sandblasting Group 3 : air-podwer abrasive polishing The composite resin was bonded to glass ionomer cement of each specimens. And the shear bond strength was tested with a universal testing machine at a cross-head speed of 1mm/min and 500kg in full scale. The results were as follows : 1. The sandblasting group(group 2) had the highest shear bond strength with $272.50{\pm}24.96\;kg/cm_2$ and the acid etching group(group 1) had the lowest shear bond strength with $192.89{\pm}29.32kg/cm_2$. 2. The no treated group(control group) had higher shear bond strength than acid etching group(group 1) (p<0.05). 3. The sandblasting group(group 2), air-powder abrasive polishing group(group 3) and no treated group(control group) had higher shear bond strength than the acid etching group(group 1) (p<0.05). 4. The sandblasting group(group 2) and air-powder abrasive polishing group(group 3) had higher shear bond strength than the no treatment group(control group), but there was not significant(p>0.05).

  • PDF

Bond strength of resin cement to $CO_2$ and Er:YAG laser-treated zirconia ceramic

  • Kasraei, Shahin;Rezaei-Soufi, Loghman;Heidari, Bijan;Vafaee, Fariborz
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.296-302
    • /
    • 2014
  • Objectives: It is difficult to achieve adhesion between resin cement and zirconia ceramics using routine surface preparation methods. The aim of this study was to evaluate the effects of $CO_2$ and Er:YAG laser treatment on the bond strength of resin cement to zirconia ceramics. Materials and Methods: In this in-vitro study 45 zirconia disks (6 mm in diameter and 2 mm in thickness) were assigned to 3 groups (n = 15). In control group (CNT) no laser treatment was used. In groups COL and EYL, $CO_2$ and Er:YAG lasers were used for pretreatment of zirconia surface, respectively. Composite resin disks were cemented on zirconia disk using dual-curing resin cement. Shear bond strength tests were performed at a crosshead speed of 0.5 mm/min after 24 hr distilled water storage. Data were analyzed by one-way ANOVA and post hoc Tukey's HSD tests. Results: The means and standard deviations of shear bond strength values in the EYL, COL and CNT groups were $8.65{\pm}1.75$, $12.12{\pm}3.02$, and $5.97{\pm}1.14MPa$, respectively. Data showed that application of $CO_2$ and Er:YAG lasers resulted in a significant higher shear bond strength of resin cement to zirconia ceramics (p < 0.0001). The highest bond strength was recorded in the COL group (p < 0.0001). In the CNT group all the failures were adhesive. However, in the laser groups, 80% of the failures were of the adhesive type. Conclusions: Pretreatment of zirconia ceramic via $CO_2$ and Er:YAG laser improves the bond strength of resin cement to zirconia ceramic, with higher bond strength values in the $CO_2$ laser treated samples.

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic

  • Tae-Yub Kwon;Seung-Hee Han;Du-Hyeong Lee;Jin-Woo Park;Young Kyung Kim
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia. MATERIALS AND METHODS. Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test. RESULTS. The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (P < .001), the PF/CON obtained a higher SBS value than the DL/CON (P < .001) and no decrease even after thermocycling (P = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (P < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (P = .002), showing no significant decrease after thermocycling (P > .05). The initial SBS of the PF/PBU was similar to the PF/CON (P = .999), but the value decreased after thermocycling (P < .001). CONCLUSION. The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.

Effect of various bleaching treatments on shear bond strength of different universal adhesives and application modes

  • Oz, Fatma Dilsad;Kutuk, Zeynep Bilge
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.20.1-20.9
    • /
    • 2018
  • Objectives: The aim of this in vitro study was to evaluate the bond strength of 2 universal adhesives used in different application modes to bleached enamel. Materials and Methods: Extracted 160 sound human incisors were used for the study. Teeth were divided into 4 treatment groups: No treatment, 35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide. After bleaching treatments, groups were divided into subgroups according to the adhesive systems used and application modes (n = 10): 1) Single Bond Universal, etch and rinse mode; 2) Single Bond Universal, self-etch mode; 3) Gluma Universal, etch and rinse mode; 4) Gluma Universal, self-etch mode. After adhesive procedures nanohybrid composite resin cylinders were bonded to the enamel surfaces. All specimens were subjected to shear bond strength (SBS) test after thermocycling. Data were analyzed using a 3-way analysis of variance (ANOVA) and Tukey post hoc test. Results: No significant difference were found among bleaching groups (35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide, and no treatment groups) in the mean SBS values. There was also no difference in SBS values between Single Bond Universal and Gluma Universal at same application modes, whereas self-etch mode showed significantly lower SBS values than etch and rinse mode (p < 0.05). Conclusions: The bonding performance of the universal adhesives was enhanced with the etch and rinse mode application to bleached enamel and non-bleached enamel.

SHEAR BOND STRENGTH OF COMPOSITE RESIN CORE USED IN COMBINATION WITH VARIOUS RESIN CEMENTS AND DENTIN BONDING AGENTS (레진 시멘트와 상아질접착제를 사용한 콤포지트 레진 코아의 전단결합강도에 관한 연구)

  • Kim Hyun-O;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.30-40
    • /
    • 2004
  • Purpose : The purpose of this study was aimed to compare the shear bond strength on dentin of three dentin bonding agents and two resin cements used in conjunction with self-cured composite resin core material. Material and method : Control group and six experimental groups were divided for this study. Control group was designated as specimens bonded with Tenure$ A&B^{(R)}$. Experimental groups were as follows : PB-BL group : specimens bonded with Prime&Bond $NT^{(R)}$, $BondLink^{(R)}$ SB-BL group : specimens bonded with $^{(R)}$, BondLink$SingleBond^{(R)}$ PB group : specimens bonded with Prime&Bond $NT^{(R)}$ SB group : specimens bonded with $SingleBond^{(R)}$ PF group : specimens bonded with $Panavia-F^{(R)}$ BI group specimens bonded with Bistite $II^{(R)}$ All specimens were stored in $37^{\circ}C$ distilled water for 24 hours, followed by the shear bond strength was tested by universal testing machine. The data was analysed statistically by Mann-Whitney test. Results : 1. For Prime&Bond $NT^{(R)}$ and $SingleBonde^{(R)}$, the shear bond strength was 0.24 MPa and 7.19 MPa each by each, while Tenure $A&B^{(R)}$ group control was measured at 13.93 MPa (p<0.05). Especially for Prime&Bond $NT^{(R)}$ it did not get conjunction with dentin. 2. For Prime&Bond $NT^{(R)}$ and $SingleBond^{(R)}$ using $BondLink^{(R)}$, there was no significant difference as a result of 11.73 MPa and 14.00 MPa each by each (p<0.05). 3. For $Panavia-F^{(R)}$ and Bistite $II^{(R)}$, they showed the highest shear bond strength as measured by 18.24 MPa and 16.09 MPa each (p<0.05).

A STUDY ON THE MARGINAL LEAKAGE OF ESTHETIC RESTORATIVE MATERIALS ON ROOT CARIES RESTORATION (치근 우식 수복에 사용되는 심미성 수복물의 변연누출에 관한 연구)

  • Han, Jin-Sun;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.205-213
    • /
    • 1993
  • The purpose of the study was to evaluate the degree of the marginal leakage of esthetic restorative materials on root caries restoration. 120 cavities were prepared to $90^{\circ}$ butt joint on all margins on the crown and root portion, and divided into 4 groups. The four groups of cavity were filled with Amalgam(Dongmuyung Dental Alloy Co., Ltd, KOREA), Silux$^{(R)}$(3M Co., USA)-Scotch Bond 2$^{(R)}$(3M Co., USA), Silux$^{(R)}$-All Bond$^{(R)}$(BISCO USA), and GC Fuji II$^{(R)}$(G-C Co., JAPAN) respectively. The apical margin of the preparation was finished to leave a flash of restorative material. The coronal margin of the preparation was finished not to leave a flash of restorative material. All specimens were sectioned longitudinally with Isomet Low speed saw(Buether Ltd, USA). The degree of dye penetration was evaluated as the parameter of marginal leakage under the stereoscope. The results were as follows. 1. At the enamel and dentin/cementum margins, the margin were finished to leave a flash of material showed less marginal leakage than that were finished not to leave a flash of material (P<0.001). 2. The enamel margins showed less marginal leakage than the dentin/cementum margins(P<0.001). 3. There was no significant difference in the degree of the marginal leakage between Silux$^{(R)}$-Scotch Bond 2$^{(R)}$ group and Silux$^{(R)}$-All Bond$^{(R)}$ group.

  • PDF

Microtensile bonding of dentin adhesives

  • Song, Yong-Beom;Lee, Se-Joon;Lee, Kwang-Won
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.585.2-585
    • /
    • 2001
  • The purpose of this study was to evaluate the microtensile bond strength of sixth-generation adhesives according to various dentin surface treatments and to observe the interface between resin(Z-100TM) and dentin by SEM. This study employed forty-five non-caries extracted human molars and three adhesive systems were used; All-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ).; group 1, 2, 3 were used AB and were respectively treated by smearing(S), ultrasonic cleansing(US), etching(E).(omitted)

  • PDF