Implementation of a Weather Hazard Warning System at a Catchment Scale (시스템 구성요소 통합 및 현업서비스 구축)

  • Shin, Yong Soon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2014.10a
    • /
    • pp.74-85
    • /
    • 2014
  • This study is a part of "Early Warning Service for Weather Risk Management in Climate-smart Agriculture", describes the delivery techniques from 840 catchment scale weather warning information using 150 counties unit special weather report(alarm, warning) released from KMA(Korea Meteorological Administration) and chronic weather warning information based on daily weather data from 76 synoptic stations. Catchment weather hazard warning service express a sequential risk index map generated by countries report occurs and report grade(alarm, warning) convert to catchment scale using zonal summarizing method. Additional services were chronic weather warning service at crop growth and accumulated more than 4 weeks, based on an unsuitable weather conditions, representing a relative risk compared to its catchment climatological normal conditions (normal distribution ) in addition to special weather report. Service provided by a real-time catchment scale map overlaid with VWORLD open platform operated by Ministry of Land, Infrastructure and Transport. Also provide a foundation for weather risk information to inform individual farmers to farm located within the catchment zone warning occur.

  • PDF

Reliability Improvement of the Electronic Security Fence Using Friction Electricity Sensor by Analyzing Frequency Characteristic of Environmental Noise Signal (환경잡음신호의 주파수특성 분석에 의한 전자보안펜스의 신뢰성 향상)

  • Yun, Seok Jin;Won, Seo Yeon;Kim, Hie Sik;Lee, Young Chul;Jang, Woo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.173-180
    • /
    • 2015
  • A passive type of fence security system was developed, which was based on electric charge detection technique. The implemented fence security system was installed at outskirts of greenhouse laboratory in the University of Seoul. The purpose of this research is to minimize false alarms by analyzing environmental noise. The existing system determines the intrusion alarm by analyzing the power of amplified signal, but the alarm was seriously affected by natural strong wind and heavy rainfall. The SAU(Signal Analysis Unit) sends input signals to remote server which displays intrusion alarm and stores all the information in database. The environmental noise such as temperature, humidity and wind speed was separately gathered to analyze a correlation with input signal. The input signal was analyzed for frequency characteristic using FFT(Fast Fourier Transform) and the algorithm that differentiate between intrusion alarm and environmental noise signal is improved. The proposed algorithm is applied for the site for one month as the same as the existing algorithm and the false alarm data was gathered and analyzed. The false alarm number was decreased by 98% after new algorithm was applied to the fence. The proposed algorithm improved the reliability at the field regarding environmental noise signal.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

A Combined Process Control Procedure by Monitoring and Repeated Adjustment

  • Park, Changsoon
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.3
    • /
    • pp.773-788
    • /
    • 2000
  • Statistical process control (SPC) and engineering process control (EPC) are based on different strategies for processes quality improvement. SPC reduces process variability by detecting and eliminating special causes of process variation. while EPC reduces process variability by adjusting compensatory variables to keep the quality variable close to target. Recently there has been needs for a process control proceduce which combines the tow strategies. This paper considers a combined scheme which simultaneously applies SPC and EPC techniques to reduce the variation of a process. The process model under consideration is an integrated moving average(IMA) process with a step shift. The EPC part of the scheme adjusts the process back to target at every fixed monitoring intervals, which is referred to a repeated adjustment scheme. The SPC part of the scheme uses an exponentially weighted moving average(EWMA) of observed deviation from target to detect special causes. A Markov chain model is developed to relate the scheme's expected cost per unit time to the design parameters of he combined control scheme. The expected cost per unit time is composed of off-target cost, adjustment cost, monitoring cost, and false alarm cost.

  • PDF

An Advanced User-friendly Wireless Smart System for Vehicle Safety Monitoring and Accident Prevention (차량 안전 모니터링 및 사고 예방을 위한 친사용자 환경의 첨단 무선 스마트 시스템)

  • Oh, Se-Bin;Chung, Yeon-Ho;Kim, Jong-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1898-1905
    • /
    • 2012
  • This paper presents an On-board Smart Device (OSD) for moving vehicle, based on a smooth integration of Android-based devices and a Micro-control Unit (MCU). The MCU is used for the acquisition and transmission of various vehicle-borne data. The OSD has threefold functions: Record, Report and Alarm. Based on these RRA functions, the OSD is basically a safety and convenience oriented smart device, where it facilitates alert services such as accident report and rescue as well as alarm for the status of vehicle. In addition, voice activated interface is developed for the convenience of users. Vehicle data can also be uploaded to a remote server for further access and data manipulation. Therefore, unlike conventional blackboxes, the developed OSD lends itself to a user-friendly smart device for vehicle safety: It basically stores monitoring images in driving plus vehicle data collection. Also, it reports on accident and enables subsequent rescue operation. The developed OSD can thus be considered an essential safety smart device equipped with comprehensive wireless data service, image transfer and voice activated interface.

Design on SDS2 On-line Poison Concentration Monitoring in CANDU

  • Kim, Seog-Nam;Jung, Ho-Chang;Kim, Sung;Kim, Ji-Hyeon;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.500-505
    • /
    • 1996
  • At the reference plant(Wolsong unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsong unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low.

  • PDF

Suggested Temperature Monitoring System for Distribution Transformers by Using Microcontroller Scheme

  • El-Gawad, Amal F. Abd
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2099-2104
    • /
    • 2015
  • The paper presents a monitoring system for the cooling of distribution transformers. The suggested system is controlled by a microcontroller scheme. The system is designed to control the oil temperature. It gives a solution to improve the cooling system by adding a number of fans especially for indoor transformers that are placed in badly-ventilated rooms. Also, the paper includes an alarm system with the possibility of tripping the transformer if it is necessary. The monitoring system consists of acquisition temperature sensor, and on-site unit. The hardware and software of the on-site unit are demonstrated with sufficient illustrations. Small prototype is constructed in the laboratory. Some laboratory experiments are carried out for examining the designed circuit by using Proteus Virtual System Modeling as well as for testing the prototype monitoring system. Concerning this research point, a study is carried out to evaluate the economic feasibility. The results are recorded and associated with many recommendations that may be valuable to electrical distribution (utility) companies.

A Study on Wearable Emergency Medical Alarm System (착용형 응급의료 경보시스템 구현에 관한 연구)

  • Kim, Dong-Wan;Beack, Seung-Hwa
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.55-61
    • /
    • 2006
  • In modern society, development of medical technology has extended the human life span. However, it has also caused some side-effects. Mostly old people who live alone are not available the medical service quickly when they are in emergency situations. Moreover heart related diseases as well are rapidly increasing with aging. This study proposes the emergency medical alarm system. This system measures the physiological signals such as ECG(electrocardiogram), temperature, and motion data, analyzes those data automatically, and sends the urgent message to the Emergency Medical Center and to their family. There are two main parts in the system. In the first part, physiological data acquisition part, the troublesome addition and deletion of body signals on existing proposed systems have been supplemented, which led to the modulized production by means of ECG sensor module, temperature sensor module, acceleration sensor module. The other part is mobile unit, which includes signal processing and transmission functions. And bluetooth allows two parts to communicate with each other. Data that are processed in the mobile unit are stored in the PC database through the WLAN using TCP/IP protocol.

  • PDF

A Study on the Design of Water Pollution Alarm System using Solar Cell (솔라셀을 적용한 수질오염 경보 시스템의 설계에 관한 연구)

  • Yoon, Seok-Am;Choi, Jang-Gyun;Yoon, Hyung-Sang;Kim, Min;Lee, Gi-Je;Cha, In-Su
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.569-572
    • /
    • 1999
  • As the industry has been growing rapidly, the problem of environmental pollution has been on the rise seriously. In this paper, we used solar cells at the power supply unit of the equipment, which has been sold at present, for measuring the quality of water in order to complement the problem. Also, to get rid of the inconvenience that the examiners must go to the job site, check and collect the polluted water we set the goal at designing the water pollution alarm system which measures the quality of water automatically using one-chip microprocessor and materializing the program.

  • PDF

A Study on Intrusion Alert Redustion Method for IDS Management (침입탐지 시스템 관리를 위한 침입경보 축약기법 적용에 관한 연구)

  • Kim, Seok-Hun;Jeong, Jin-Young;Song, Jung-Gil
    • Convergence Security Journal
    • /
    • v.5 no.4
    • /
    • pp.1-6
    • /
    • 2005
  • Today the malicious approach and information threat against a network system increase and, the demage about this spread to persnal user from company. The product which provides only unit security function like an infiltration detection system and an infiltration interception system reached the limits about the composition infiltration which is being turn out dispersion anger and intelligence anger Necessity of integrated security civil official is raising its head using various security product about infiltration detection, confrontation and reverse tracking of hacker. Because of the quantity to be many analysis of the event which is transmitted from the various security product and infiltration alarm, analysis is difficult. So server is becoming the charge of their side. Consequently the dissertation will research the method to axis infiltration alarm data to solve like this problem.

  • PDF