• Title/Summary/Keyword: Air distribution .rate

Search Result 541, Processing Time 0.03 seconds

Accumulation Property in Human Body of Benzene Derived from Groundwater According to Exposure Pathway (지하수에서 유래한 벤젠의 노출경로별 인체축적특성)

  • 김상준;이현호;박지연;이유진;유동한;양지원
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.12-27
    • /
    • 2004
  • The contamination pattern of indoor air was simulated when groundwater dissolving benzene was used for household activities. Indoor exposure scenario consisted of inhalation, ingestion, and dermal absorption. Physiologically based pharmacokinetic (PBPK) model was used to analyze how benzene exposed to human body was distributed in internal organs. Main exposure pathways contributing total internal dose were inhalation and ingestion while the contribution of dermal absorption was very small. Man showed higher exposure rate than woman due to his higher breath rate. For a short-term exposure, benzene concentration in venous blood of SPT, RPT and liver changed rapidly while slowly did in venous blood of adipose tissue at a low concentration. For a long-term exposure, woman accumulated about 2.1 times higher than man. Most of benzene exposed to human body was removed by exhalation and metabolism at lung and liver, respectively. For inhalation and ingestion, the benzene removals by exhalation were 69.8 and 48.4%, respectively. Relative importance of removal mechanism was different according to the inflow displacement of benzene. The results obtained from this study would help understand exposure, distribution, and removal phenomena and make plans for the reduction of the health risk associated with the contaminated groundwater by various organic compounds.

Physiological and Ecological Characteristics of Lipid-Producing Botryococcus Isolated from the Korean Freshwaters (한국산 고지질 미세조류 Botryococcus의 분포 및 생장 특성)

  • Shin, Sang-Yoon;Jo, Beom-Ho;Lee, Hyung-Gwan;Oh, Hee-Mock
    • Korean Journal of Environmental Biology
    • /
    • v.31 no.4
    • /
    • pp.288-294
    • /
    • 2013
  • Recently, sustainable production of biofuel using algal biomass is being pursued because of its enormous potential. First and foremost, securing superior strains to develop an efficient production system for algal biodiesel through screening or genetic improvement of microalgae is necessary. The genus of Botryococcus is regarded as one of the superior microalgae for biodiesel production due to its ability to accumulate high amounts of lipids and hydrocarbons. However, its low growth rate is a bottleneck for large-scale production and commercialization. The purpose of this study is to obtain indigenous Botryococcus strains which possess high lipid content and biomass productivity. The Botryococcus sp. was isolated from the Seobu Reservoir in Jeju Island and identified as Botryococcus sudeticus J2 by comparative analysis of 18s rRNA gene and ITS regions. The biomass productivity and lipid content of B. sudeticus J2 were 0.116 g $L^{-1}day^{-1}$ and 40.1% of dry wt., respectively. This was higher than the value of B. braunii UTEX 572, which is widely regarded as a superior strain among Botryococcus species. The relatively high growth rate of B. sudeticus J2 was achieved under a light intensity of 240 ${\mu}mol$ photons $m^{-2}s^{-1}$ with ambient air spargingwhen compared to 120 ${\mu}mol$ photons $m^{-2}s^{-1}$ with 2% $CO_2$ supply. In summary, it is likely that the isolated B. sudeticus J2 can be used for the mass cultivation and biodiesel production.

Quality and Yield Characteristics of Potato (Solanum tuberosum L.) Grown at Paddy Field in Spring Season

  • Im, Ju Sung;Cho, Ji Hong;Chang, Dong Chil;Jin, Yong Ik;Park, Young Eun;Chun, Chung Gi;Kim, Dong Un;Yu, Hong Seob;Lee, Jong Nam;Kim, Myung Jun
    • Horticultural Science & Technology
    • /
    • v.31 no.1
    • /
    • pp.24-31
    • /
    • 2013
  • This study was conducted to determine the characteristics of quality and yield in potatoes grown at paddy field before rice transplantation during the spring season. Three potato cultivars ('Jowon', 'Haryeong', and 'Goun') were grown in Gangneung (asl 5 m) and Seocheon (asl 20 m). In both locations, weather condition belonged to the fourth zone (spring cropping) in potato production location's distribution of Korea. Daily mean soil temperature in both the locations was $0.2-0.6^{\circ}C$ lower than air temperature, while soil moisture was adequate level to potato growth in spite of spring drought. TR ratio was not affected by location, but by cultivar. Specific gravity, starch content, dry matter rate, and yield were significantly influenced by location and by cultivar. There was no difference in total tuber number by location, however there was a large gap in marketable tuber yield according to locations and cultivars. There were high negative relationships between yield and main qualities such as dry matter rate and starch content, while high positive correlation was observed between main qualities. It was possible to produce potato before rice transplanting at drained paddy fields located in representative two locations of potato spring cropping and their characteristics in growth and quality were similar to those generally well known in upland cultivation. Paddy field was thought to be more favorable than upland in terms of available soil moisture supply against spring drought. Further research, however, was needed to increase soil temperature and also preliminary review on proper cultivar according to location seemed to be needed for high yield.

The Study of Standardization of Temperature Distribution of Interstitial Hyperthermia -In Phantoms and Living cat's brain tissue (Normal Tissue)- (915 MHz 극초단파 자입온열시 온도분포 적정화에 관한 연구 -조직등가물 및 가묘대뇌를 대상으로-)

  • Kyoung Hwan Koh;Cho Chul Koo;Park Young Hwan;Yoo Seong Yul;Kim Jong Hyun;Lee Seung Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.7-15
    • /
    • 1990
  • The ultimate objective of our experiment is to obtain the precise distribution of temperature in malignant tumors occurring in cerebral parenchyme of human beings when we will carry out interstitial hyperthermia in the near future. To achieve this purpose, first of all, it is necessary to make an attempt at performing interstitial hyperthermia in vivo under the similar condition of human beings. Therefore, we chose cats as materials much alike tissue characteristics of human beings. Moreover, it is also necessary to get the basic data from dynamic phantom in order to standardize and compare results obtained from interstitial hyperthermia carried out in cats. By having performed these experiments we got the following results. 1) On doing interstitial hyperthermia with 915 MHz microwave, the possible treated volume was 2 cm by 2 cm by 6 cm according to $50\%$ specific absorption rate (SAR). 2) The distribution of temperature within non-circulated static phantom was much the same as power density in air, but we observed that the temperature, within $5\~10$ minutes, rose to more higher than $55^{\circ}C$ not measured with Ga-As fiberoptic thermistor which was not impeded by microwave after performing interstitial hyperthermia. 3) Within dynamic phantom in which normal saline was circulating, temperature reached steady state which was maintained for more than 45 minutes through transit period in 5 minutes after starting interstitial hyperthermia. 4) When we interrupted circulation in the dynamic phantom, we observed that temperature rose to the same level as in the static phantom. 5) We could carry out interstitial hyperthermia safely when we used the generating power below 5 watts. Abrupt interruption of circulation caused a rapid increase in temperature. Times taking to rise to maximum $55^{\circ}C$ were 15.2 minutes (SE 0.4),9.7 minutes (SE 0.3), and 6.3 min-utes (SE 0.4) respectively with generating powers of 5,10, and 15 watts.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Changes in the Climate in recent 60 years and Distribution of Agroclimatic Resources in Korea (우리나라 최근(最近) 60년(年의) 기후변화(氣候變化)에 따른 농업기후자원(農業氣候資源) 분포(分布))

  • Lee, Jeong-Taek;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.160-167
    • /
    • 1994
  • Meteorological elements such as air temperature, relative humidity, rainfall, sunshine duration, and so on observed by Korea Meteorological Administration, were analyzed to estimate the climatic change and to establish countermeasures in agriculture. Climatic differences were compared between two periods, early($1931{\sim}1960$) and late($1961{\sim}1990$), by calculating climatic resource indices, coldness index and warmth index of the two periods. Annual mean air temperatures of Seoul, Taegu, and Pusan in 1910's were 10.7, 12.3, and $13.4^{\circ}C$, respectively, having increased by $1.3^{\circ}C$ in Seoul and Taegu and by $0.9^{\circ}C$ in Pusan in 1990's. Mean air temperature in the spring($March{\sim}May$) increased by $0.69^{\circ}C$, which is a higher increasing rate than in the other seasons ($0.26{\sim}0.33^{\circ}C$). Regional differences exist in annual mean air temperature between the early and late part of the 20th century with little increase in this experiment did not germinate at pH 1.0. At pH 2.0, the flowering cabbage and geranium in the middle northern area, while in the southern part about $1^{\circ}C$increase was recorded during the last period. In the late period the annual rainfall increased by 100mm, except for the western coast area and the middle northern area. The P/E ratio showed a trend of an annual increase in the late period, being higher in the summer and lower in the winter. Relative humidity showed slight differences in seasons and regions but annual values did not. Duration of sunshine decreased by about an hour in the spring. Coldness index and warmth index of the late period were higher by 3.7 and 1.0 than those of the early period, respectively.

  • PDF

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

Seasonal and Inter-annual Variations of Sea Ice Distribution in the Arctic Using AMSR-E Data: July 2002 to May 2009 (AMSR-E 위성 데이터를 이용한 북극해빙분포의 계절 변동 및 연 변동 조사: 2002년 7월 ~ 2009년 5월)

  • Yang, Chan-Su;Na, Jae-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.5
    • /
    • pp.423-434
    • /
    • 2009
  • The Arctic environment is sensitive to change of sea-ice distribution. The increase and decrease of sea ice work to an index of globe warming progress. In order to predict the progress of hereafter earth global warming, continuous monitoring regarding a change of the sea ice area in the Arctic should be performed. The remote sensing based on an artificial satellite is most effective on the North Pole. The sea ice observation using a passive microwave sensor has been continued from 1970's. The determination of sea ice extent and ice type is one of the great successes of the passive microwave imagers. In this paper, to investigate the seasonal and inter-annual variation of sea-ice distribution we used here the sea ice data from July 2002 to May 2009 around the Arctic within $60^{\circ}N$ for the AMSR-E 12.5km sea-ice concentration, a passive microwave sensor. From an early analysis of these data, the arctic sea-ice extent has been steadily decreasing at a rate of about 3.1%, accounting for about $2{\times}10^5\;km^2$, which was calculated for the sea-ice cover reaching its minimum extent at the end of each summer. It is also revealed that this trend corresponds to a decline in the multi-year ice that is affected mainly by summer sea surface and air temperature increases. The extent of younger and thinner (first-year) ice decreased to the 2007 minimum, but rapidly recovered in 2008 and 2009 due to the dramatic loss in 2007. Seasonal variations of the sea-ice extent show significant year-to-year variation in the seasons of January-March in the Barents and Labrador seas and August-October in the region from the East Siberian and Chukchi seas to the North Pole. The spatial distribution of multi-year ice (7-year old) indicates that the perennial ice fraction has rapidly shrunk recently out of the East Siberian, Laptev, and Kara seas to the high region of the Arctic within the last seven years and the Northeast Passage could become open year-round in near future.

Errors in Net Ecosystem Exchanges of CO2, Water Vapor, and Heat Caused by Storage Fluxes Calculated by Single-level Scalar Measurements Over a Rice Paddy (단일 높이에서 관측된 저장 플럭스를 사용할 때 발생하는 논의 이산화탄소, 수증기, 현열의 순생태계교환량 오차)

  • Moon, Minkyu;Kang, Minseok;Thakuri, Bindu Malla;Lee, Jung-Hoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.227-235
    • /
    • 2015
  • Using eddy covariance method, net ecosystem exchange (NEE) of $CO_2$ ($F_{CO_2}$), $H_2O$ (LE), and sensible heat (H) can be approximated as the sum of eddy flux ($F_c$) and storage flux term ($F_s$). Depending on strength and distribution of sink/source of scalars and magnitude of vertical turbulence mixing, the rates of changes in scalars are different with height. In order to calculate $F_s$ accurately, the differences should be considered using scalar profile measurement. However, most of flux sites for agricultural lands in Asia do not operate profile system and estimate $F_s$ using single-level scalars from eddy covariance system under the assumption that the rates of changes in scalars are constant regardless of the height. In this study, we measured $F_c$ and $F_s$ of $CO_2$, $H_2O$, and air temperature ($T_a$) using eddy covariance and profile system (i.e., the multi-level measurement system in scalars from eddy covariance measurement height to the land surface) at the Chengmicheon farmland site in Korea (CFK) in order to quantify the differences between $F_s$ calculated by single-level measurements ($F_s_{-single}$ i.e., $F_s$ from scalars measured by profile system only at eddy covariance system measurement height) and $F_s$ calculated by profile measurements and verify the errors of NEE caused by $F_s_{-single}$. The rate of change in $CO_2$, $H_2O$, and Ta were varied with height depending on the magnitudes and distribution of sink and source and the stability in the atmospheric boundary layer. Thus, $F_s_{-single}$ underestimated or overestimated $F_s$ (especially 21% underestimation in $F_s$ of $CO_2$ around sunrise and sunset (0430-0800 h and 1630-2000 h)). For $F_{CO_2}$, the errors in $F_s_{-single}$ generated 3% and 2% underestimation of $F_{CO_2}$ during nighttime (2030-0400 h) and around sunrise and sunset, respectively. In the process of nighttime correction and partitioning of $F_{CO_2}$, these differences would cause an underestimation in carbon balance at the rice paddy. In contrast, there were little differences at the errors in LE and H caused by the error in $F_s_{-single}$, irrespective of time.

Effect of NO Treatment during Shelf Life of 'Hayward' Kiwifruit after Storage at Cold Temperature (Nitric Oxide 처리가 저온 저장된 키위과실의 상온 유통 중 품질에 미치는 영향)

  • Eum, Hyang Lan;Lee, Eun Jin;Hong, Sae Jin
    • Horticultural Science & Technology
    • /
    • v.32 no.5
    • /
    • pp.666-672
    • /
    • 2014
  • The effect of nitric oxide (NO) treatment on the quality of kiwifruit, cv. Hayward, was studied at room temperature after cold storage for one or three months at $0^{\circ}C$. Kiwifruits cold-stored for one month were treated with $200{\mu}L{\cdot}L^{-1}$ NO and subsequently transferred to room temperature to monitor quality changes over the course of their shelf life. Weight loss was high in fruits not treated with NO. Ethylene production was delayed for two days by NO treatment, and respiration rate was reduced to less half than that of the control. The kiwifruits stored for three months were treated with $N_2$ and 100, 200, or $500{\mu}L{\cdot}L^{-1}$ NO, or air alone. The highest weight loss was observed in kiwifruit treated with $100{\mu}L{\cdot}L^{-1}$ NO. While ethylene production was high in fruits treated with $100{\mu}L{\cdot}L^{-1}$ NO and without the treatment, it was relatively low in the kiwifruit treated with 200 and $500{\mu}L{\cdot}L^{-1}$ NO. Firmness was abruptly decreased in fruits not treated with NO, while the kiwifruit exposed to $200{\mu}L{\cdot}L^{-1}$ NO maintained the s ame level of f irmness for 9 days a t room t emp erature. In addition, growth o f Botrytis cinerea was inhibited by NO as compared with the air and $N_2$ treatments. Our findings indicate that NO can be used effectively for prolonging shelf life and maintaining fruit quality during distribution after cold storage. The optimum NO concentration for cold-stored kiwifruits was found to be $200{\mu}L{\cdot}L^{-1}$.