• 제목/요약/키워드: Age of Building

검색결과 783건 처리시간 0.026초

한랭환경에서 타설되는 고로슬래그 시멘트 콘크리트의 설계기준강도 확보 기법 (Designed Compressive Strength Assurance Method of Management Period for Winter Concrete Using Blast Furnace Slag)

  • 이영준;이혁주;한준희;현승용;서항구;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.42-43
    • /
    • 2018
  • The research is to suggest the compensating strength values depending on various managing periods of concrete based on the strength development model calculated with equivalent age method for 20% of blast furnace slag replaced concrete. As a result, for 28 days of managing period, 9, 6, and 3MPa of compensating strength values were suggested when the temperatures were from 4 to 6℃, from 6 to 12℃, from 12 to 17℃, respectively. Additionally, for 42 days of managing period, 6 and 3MPa of compensating strength value was suggested when the temperature was from 4 to 7℃, from 7 to 12℃, and for 56 days of managing period, 3MPa of compensating strength value was suggested when the temperature was from 4 to 9℃. Furthermore, for 28, 42, 56, and 91 days of managing periods, any compensating strength values were needed when the temperature were higher than 17, 12, 9, and 4℃, respectively.

  • PDF

콘크리트 양생 모니터링을 위한 거푸집 일체형 무선센서네트워크(WSN) 시스템 (Form Integrated Wireless Sensor Network for Monitoring of Concrete Curing)

  • 이성복;박원준;조명원;이승엽;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.173-175
    • /
    • 2012
  • Temperature during concrete curing can be effectively used to predict the early age strength of concrete However, various current methods have limits to provide the temperature data in real time due to harsh working environment including frequent cutting of wires. This paper presents the results of our investigation of an all-in-one Wireless sensor network (WSN) for the management of the curing temperature of in-placed concrete at early curing stages. Also, the network device for transmission can be easily separated from the probe sensor part and reused consistently. The field experiment entailed measuring the curing temperature of concrete using the WSN. After fresh concrete was poured into the formworks, the signals were measured at a 150 m radius from the field office. The signal was acquired for 28 days without any dispersion or interruption at the construction site; therefore, this study confirms the applicability of the proposed system to a construction site.

  • PDF

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

단열양생재 변화 및 열선 전력용량 차이에 따른 슬래브 콘크리트의 온도이력 특성 (Characteristic of Temperature History of Slab concrete by the Change of Insulation Curing Material and Difference of Heated cable Power Capacity.)

  • 정은봉;안상구;정상현;고경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.334-336
    • /
    • 2013
  • In this study, the temperature history was evaluated for the improved bubble sheets combining hot wires and PE films, which were developed under the extreme environmental condition of -10℃ and applied on the top surface of slab to prevent initial damage by freezing. Results can be summarized as follows. If improved bubble sheets combining hot wires with different capacity on double and quadruple bubble sheets are used, the temperature history for all materials decreased to 2~3℃ below zero but all test materials except Type 1 secured the accumulative temperature of 45° D·D at 7 days of material age, required for the prevention of initial freezing damage. This indicates the bubble sheets can prevent the initial damage by freezing.

  • PDF

서울 시내 일부 주차장의 공기중 섬유농도에 영향을 미치는 인자 분석 (The Factor Analysis of Airborn Fiber Concentrations at Parking Lots in Seoul)

  • 문지영;김현욱
    • 한국산업보건학회지
    • /
    • 제4권2호
    • /
    • pp.157-167
    • /
    • 1994
  • This study was conducted to analyze the relationship between the types of fiber and its content and the levels of airborne fiber concentrations at eight parking lots where sprayed insulation material was found on the walls and ceilings. Also this study was designed to find the relationship between the levels of airborne fiber concentrations and such variables as air current, humidity, total exhaust volume, surface condition of insulation material and building age. The results obtained were as follows : 1. No significant correlation was found between the levels of airborne tiber concentration and the building age, air current, humidity, total exhaust volume, space and the number of traffics. 2. A significant correlation was found between the levels of airborne fiber concentration and the MMMF content of the insulation material(r=0.7594). However, no significant correlation was found between the levels of airborne fiber concentration and total fiber content of insulation material. 3. The differences of the airborne fiber concentrations among Cateogory 1, 2 and 3 classified by the degrees of surface insulation material maintenance were very significant. 4. Two bulk samples contained 30% crodicolite and 1% anthophylite. The MMMFs, in all parking lots, included mineral wool, cellulose fiber, trace cellulose fiber, trace tiber glass and vermiculite. 5. The mean value and the range of airborne fiber concentrations at 8 parking lots were $0.0239{\pm}0.0095f/cc$ and 0.0054-0.0447 f/cc, respectively. The fiber concentrations of 35 out of 38 samples(92%) were over 0.01 f/cc which is the Environment Administration's recommended asbestos level for the underground space. This study suggests that most of building insulation materials used in Korea, contain MMMF and sometimes asbestos. Currently, MMMF pollution levels may exceed the Environment Administration's recommended level for underground space. It has been found that airborne fiber concentrations increased significantly with MMMF content and with the maintenance condition of surface material. Therefore, it is recommended that a proper management technique should be developed and immediately implemented since the conditions of surface material will be gradually deteriorated due to building age and usage. Since health hazards of the MMMF, similar to those of asbestos, are being gradually acknowledged, a proper management technique which is applicable to control total airborne fiber concentrations, both asbestos and MMMF, be developed and an acceptable indoor air standard be promulgated as early as possible.

  • PDF

용출수를 사용한 플라이애쉬 혼입 모르타르의 강도특성에 관한 연구 (A Study on the Compressive Strength Property of Mortar with Fly Ash Using Water Eluted from Recycled Coarse Aggregates)

  • 신상엽;정의창;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.31-32
    • /
    • 2013
  • ThThe purpose of this study is to investigate the compressive strength properties of fly ash using water eluted from recycled coarse aggregate. When fly ash come into contact with water, they have not a autonomously chemical reaction. But fly ash is a pozzolan reaction when fly ash come into contact with water and calcium hydroxide(Ca(OH)2) in alkaline environment. For that reason, if water eluted from recycled coarse aggregate use mixture water, fly ash is expected to reaction of pozzolan reaction property in early stage. According to the experimentation result, ICP-MS analysis showed water eluted from recycled coarse aggregate has a high alkali-ash value of pH of 12 and over. And mixing ratio 30% fly ash mortar using water eluted from recycled coarse aggregate showed a similar strength of plain mortar due to the pozzolan reaction. Also, poor strength in initial age, disadvantage of mortar using fly ash, can be improved as hydration in early age is expedited due to calcium hydroxide(Ca(OH)2) and unhydrated cement component eluted from recycled aggregate mortar.

  • PDF

공공건축물의 합리적인 운영평가기준 설정 방향에 관한 연구 (The Study on Evaluation Basis of Management Strategy in Public Buildings)

  • 이상범;노병옥
    • 한국건축시공학회지
    • /
    • 제9권2호
    • /
    • pp.69-76
    • /
    • 2009
  • Recently, the twenty-first century is called "the age of localization and regionalization" in Korea. So, local government should need to keep balance between the existing administrative management and new management strategies based on CEO's mind in order to deal with the situation of such that(the age of localization and regionalization) and improve efficiency of public service. In addition, they build public buildings after that they should operate and maintain them regularly. However, Korea local governments have tried to run many projects to expand insufficient local finance that was only for profit oriented public projects without considering management. Therefore, this paper is a basic study to establish and suggest the reasonable operation plan for local government by examining and reviewing actual operation condition in the public buildings. With the evaluation method which is demanded from public construction management to introduce a civil management technique manages an investment mind standard and management basis of assessment, proposes 8 sides of financial affairs, real estate maintenance and facility management, achievement evaluation, environmental safe crisis management, judiciary and explanation responsibility with base.

배쳐플랜트배합시험 및 실대부재시험을 통한 콘크리트의 조기강도 발현특성에 관한 실험적 연구 (An Experimental Study on the High Early Strength Development Properties of Concrete according to Batcher Plant Test and Mock-up Test)

  • 이지환;이종석;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.1-5
    • /
    • 2008
  • In this study, batcher plant composition test and mock-up test were carried out to conduct comparison and analysis on flow behavior and strength properties of concrete at early age. As a result, it was found that slump and amount of air in batcher plant composition test reached the target range. As for compressive strength, composition using HESPC showed the most excellent strength development. In mock-up test which was carried out to find out the strength properties, two methods with specimen and core test body both revealed HESPC as the most excellent composition. However, strength estimation with ultrasonic survey presented less reliable data. As a result of the previously conducted indoor composition test and the mock-up test in this study, target performance of concrete at early age was 4day/cycle. It was found that the optimum conditions that meet the required strength, 5MPa/18hr and 14MPa/36hr in mullion and transom are; curing temperature above 15℃, W/B 45%, unit-water 165kg/㎥ and CHC cement.

  • PDF

우리나라 공공건물의 내용연수 추정: RCC를 중심으로 (An Estimation on Average Service Life of Public Buildings in South Korea: In Case of RCC)

  • 권정훈;조진형;오현승;이세재
    • 산업경영시스템학회지
    • /
    • 제46권1호
    • /
    • pp.84-90
    • /
    • 2023
  • ASL estimation of public building is based on how appropriate the maximum age of the asset is derived based on the age record of the asset in the statistical data owned by public institutions. This is because we get a 'constrained' ASL by that number. And it is especially true because other studies have assumed that the building is an Iowa curve R3. Also, in this study, the survival rate is 1% as the threshold value at which the survival curve and the predictable life curve almost coincide. Rather than a theoretical basis, in the national statistical survey, the value of residual assets was recognized from the net value of 10% of the acquisition value when the average service life has elapsed, and 1% when doubling the average service life has elapsed. It is based on the setting mentioned above. The biggest constraint in fitting statistical data to the Iowa curve is that the maximum ASL is selected at R3 150%, and the 'constrained' ASL is calculated by the proportional expression on the assumption that the Iowa curve is followed. In like manner constraints were considered. First, the R3 disposal curve for the RCC(reinforced cement concrete) building was prepared according to the discarding method in the 2000 work, and it was jointly worked on with the National Statistical Office to secure the maximum amount of vintage data, but the lacking of sample size must be acknowledged. Even after that, the National Statistical Office and the Bank of Korea have been working on estimating the Iowa curve for each asset class in the I-O table. Another limitation is that the asset classification uses the broad classification of buildings as a subcategory. Second, if there were such assets with a lifespan of 115 years that were acquired in 1905 and disposed of in 2020, these discarded data would be omitted from this ASL calculation. Third, it is difficult to estimate the correct Iowa curve based on the stub-curve even if there is disposal data because Korea has a relatively shorter construction history, accumulated economic wealth since the 1980's. In other words, "constrained" ASL is an under-estimation of its ASL. Considering the fact that Korea was an economically developing country in the past and during rapid economic development, environmental factors such as asset accumulation and economic ability should be considered. Korea has a short period of accumulation of economic wealth, and the history of 'proper' architectures faithful to building regulations and principles is short and as a result, buildings 'not built properly' and 'proper' architectures are mixed. In this study, ASL of RCC public building was estimated at 70 years.

폐식용유 혼입 및 양생방법에 따른 순환잔골재 사용 고로슬래그 벽돌의 품질특성 (Quality Properties of Blast Furnace Slag Brick Using the Recycled Fine Aggregates Depending on Waste Oil and Curing Method)

  • 박경택;손호정;김대건;김복규;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.61-62
    • /
    • 2011
  • This study reviewed the effect of W/B, WO and curing method on the quality properties of RA using the BS brick under the zero cement condition. compressive strength was found to show an increasing trend as W/B increased, but to show a improvement in case steam curing was conducted, showing a higher increase at 1 day age in comparison with 7 day age. In addition, the compressive strength on the mixing of WO didn't show any specific trend. The absorption tended to decrease as W/B increased and met the less than 10% regulation value at 30~35% W/B in case WO was used, there appeared a decrease attributable to capillary pore filling effect due to saponification. On the other hand, compressive strength increases, th absorption showed a gradually decreasing tendency.

  • PDF