• Title/Summary/Keyword: 포집 효율

Search Result 320, Processing Time 0.044 seconds

A Study on the Collection Efficiency of A Tritium Bubbler (삼중수소 버블러의 포집효율에 대한 고찰)

  • Shin Jae-sin;Lee Seung-Ho;Park Kwang-Ryeol
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.172-181
    • /
    • 2005
  • Collection Efficiency of a tritium bubbler being used at domestic nuclear power plants was studied. Equilibrium is attained while tritium vapour in air passes through the bubbler. When a lot of gas sample passes through the bubbler, the tritium concentration of water is raised and volume of water is decreased or increased. These phenomena give effect to the collection efficiency. Estimation of the tritium concentration of the water agreed with our experiments. If relative humidity is higher than 0.5, the efficiency becomes lower than 1 and if relative humidity is lower than 0.5, the efficiency becomes higher than 1, provided collected tritium is evaluated with original volume of the water. Though the relative humidity is riot 0.5, the efficiency can be maintained near 1 by making $\frac{saturated\; water\; vapour(cm^3_w)\times volume \; of \; gas \; sample(cm^3)}{volume\; of\; water(cm^3)}$ small

  • PDF

Particle Collection Efficiency Using Granular Cyclone (Granular Cyclone에 의한 입자의 포집효율)

  • 정창훈;김민철;임경수;이규원;박찬일
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.497-498
    • /
    • 2003
  • cyclone은 원심력을 이용하여 입자를 포집하는 집진장치로 간단한 구조 때문에 입자의 전처리 장치로 많이 사용되어 왔다. 그러나 미세 입자의 제어가 어렵고, 포집 효율의 증가를 위해 유량을 증가시킬 경우 유랑의 증가에 의한 압력손실과 에너지의 손실이 증가하며, 유량을 감소시킬 경우 입자의 포집 효율이 급격히 감소하는 점 등의 단점이 있다. 따라서, 미세 입자에 대한 포집 효율을 증가시키기 위해 싸이클론의 구조 및 형채를 변화시키는 많은 연구가 수행된 바 있다(Lim et al., 2001; Lim et al., 2003). 본 연구에서는 granule에 의한 관성충돌 효과를 이용하여, 일반적인 cyclone의 설계를 목적으로 하였다. (중략)

  • PDF

산업용 여과포집진장치의 운전 및 성능

  • 박영옥
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.03a
    • /
    • pp.47-67
    • /
    • 1995
  • 현재 국내 산업공정 및 먼지발생공정에서는 발생된 먼지를 포집 제거하기 위해 머지 발생원의 특성에 따라 각종 집진기술을 적용하고 있는데, 여과포집진장치의 경우 년간 고체연료 사용량이 1,000톤 이상인 사업장을 대상으로 조사한 자료에 의하면 1985년에는 1,374기 였고, 1989년에는 2,100기, 1991년에는 5,710기로 년 평균 110% 이상 증가하는 추세를 나타냈다. 이와 같은 증가 추세는 여과포집진 기술이 다른 집진기술에 비해 여러가지 장점을 갖고 있기 때문이라고 볼 수 있다. 앞으로 산업체에서는 먼지배출 허용농도의 강화 대응 뿐만 아니라 대기오염 방지 측면과 인간의 호흡기에 유입되어 폐에 침착되는 미세한 입자까지 포집, 제거하기 위해서는 먼지제거 설비에는 고효율 집진기술을 적용하여야 한다. 따라서 본 글에서는 선진국에서 고효율 집진기술로 판명되고 있는 여과포집진기술에 대해 먼지포집 특성과 장치의 구성을 먼저 살펴보고 최근에 산업체 및 발전소에 적용하고 있는 여과포집진기술의 운전현황을 고찰하여 미래에 한국형 종합배가스 처리용 여과포집진기술을 개발하기 위한 기초자료로 활용하고자 한다.

  • PDF

Analytic Solution of the Single Collection Efficiency between the Charged Sphere Collector and Particles (대전된 포집구와 입자의 포집효율에 관한 일반 해)

  • 이승주;정창훈;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.215-216
    • /
    • 2000
  • Granular Bed Filter에서의 미세입자 제거에 대한 연구, 특히 정전기력을 이용한 미세입자의 포집효율에 관한 연구는 수많은 연구자들에 의해 수행되어 왔으나, 이론식 내의 입자들의 관성, 유동장 그리고 입자에 작용하는 전기력의 복합성 때문에 직접적인 일반 해를 구하기가 어려운 것이 사실이다. 정전기력을 이용한 입자의 여과특성 및 효율에 대한 이론적 연구는 주로 외부 전기장을 주었을 경우와 포집체와 입자가 모두 대전되었을 경우를 중심으로 수행되어 왔다. (중략)

  • PDF

Experimental Study on the Characteristics of CO2 Capture with Spray Towers Using Ammonia Solution (암모니아수 흡수제를 사용하는 분무탑의 이산화탄소 포집 기본특성에 관한 실험적 연구)

  • Lim, Youngbok;Choi, Munkyoung;Lee, Jinwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.165-172
    • /
    • 2014
  • Experiments were conducted to identify basic characteristics of $CO_2$ capture using a spray tower with a single nozzle. Results were evaluated in terms of $CO_2$ saturation which is the main determining factor of regeneration energy, and capture efficiency under various operating conditions. Changes in the capture efficiency under various conditions are well expressed as a monotone increasing function of the relative solvent $(NH_3):CO_2$ flow rate. Although changes in $CO_2$ saturation are also well described as a function of the $NH_3/CO_2$ flow rate ratio, these are expressed as a monotone decreasing function, in contrast with the increasing function of $CO_2$ efficiency. In recent research on the relationship between $CO_2$ saturation and capture efficiency, $CO_2$ saturation was found to decrease when capture efficiency increased. In conclusion, the results show that the amount of solvent used for achieving high capture efficiencies is excessive, as is the amount of regeneration energy needed.

Application of Cyclone to Removal of Hot Particulate in Hot Cell (Hot Cell 내의 고방사능 분진 제거를 위한 사이클론 적용 실험)

  • Kim Gye Nam;Lee Sung Yeol;Won Hui Jun;Jung Chong Hun;Oh Won Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.67-75
    • /
    • 2005
  • The size and main ingredient of hot particulate generated during the nuclide experiment in hot cells of nuclear facilities were 0.5300 $\mu$m and UO$\_2$. A cyclone filter equipment which consists of a cyclone and Bag/HEPA filter was devised to remove hot particulate generated during the nuclide experiment in hot cells of nuclear facilities. The experimental conditions to maximize the collection efficiency of hot particulate were suggested through experiments done with the cyclone filter equipment. With the large size of simulated particulate, the collection efficiency of the particulate was high. When the size of simulated particulate was more than 5 $\mu$m, the collection efficiency of the particulate was more than $80\%$ and when the size of simulated particulate was less than 1.0 urn, the collection efficiency decreased by less than $70\%$. If the inflow velocity of simulated particulate was increased, the collection efficiency of the particulate was also increased. When the inflow velocity of simulated particulate was more than 12m/sec, the collection efficiency was higher than $70\%$, but after 17 m/sec inflow velocity, no change observed. The collection efficiency of the simulated particulate can be enhanced with the length of vortex finder inside the chamber. With the length of vortex finder, 7.2cm, the observed collection efficiency of the particulate was the maximum. Moreover, when the sub-cone was attached under the cyclone, the collection efficiency of cyclone increased $2\%$. It was found that effect by attachment of sub-cone was not serious.

  • PDF

Local Exhaust Ventilation Characteristics of Coal Dust in Coal Preparation Plant of a Coal Mine (석탄광산 선탄장에서 비산분진의 국소배기 특성)

  • Lee, Seung-Chul;Jo, Woo-Hyun;Park, Young-Rok;Ok, Yun-Yong;Kim, Tae-Hyuk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.259-262
    • /
    • 2009
  • 본 연구에서는 석탄광산 선탄장설비와 국소배기시스템의 일부를 모형화하여 포집특성과 유동특성실험을 수행하였으며 동일조건에서 수치해석을 수행하여 그 결과를 비교 검토하였다. case 5가 46.35%의 가장 높은 포집효율을 보였으며 실험의 3가지 변수 중 고무 커튼의 사용유무가 국소배기시스템의 포집효율에 가장 큰 영향을 미치는 것으로 판단된다. 또한 case 1, 5, 6에 대해 포집된 입자크기 확인 결과, 포집성능이 우수한 case 5가 입경 $20{\mu}m$ 초과 입자들이 약 55%로 가장 많이 포집된 것을 알 수 있었다. 따라서 제어거리는 0.5m 이상이 적절한 것으로 판단된다.

  • PDF

A study of the fabrication of surface coated SiC whiskers on carbon fiber for various filter applications

  • Choe, Yu-Yeol;Kim, Jun-Gyu;Park, Si-Jeong;Choe, Du-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.83-83
    • /
    • 2010
  • 산업이 고도화되는 과정에서 에너지의 고효율화를 위하여 고온, 고압 등의 극한환경 하의 공정이 불가결하며, 이에 따라 초미세분진인 나노 입자가 증가되고 있다. 이에 따라 해당 나노의 입자 처리를 위하여 다양한 용도에서의 고온 필터가 산업적으로 요구되고 있다. 본 연구에서는 디젤엔진 매연저감 후처리 장치, 소각로, 발전소 등의 미세 분진 포집 필터로서의 응용을 위해, 카본 파이버에 SiC 휘스커를 증착하는 실험을 진행하였다. 휘스커 증착 공정은 촉매없이 SiC 휘스커를 카본 파이버 위에 화학증착하였다. 휘스커 성장 시 증착 조건의 변화를 통하여 다양한 휘스커의 증착 형태 및 미세구조를 관찰하였다. 또한 높은 포집 효율 및 기체투과도를 갖추기 위해, 휘스커가 증착된 시편의 포집효율 및 기체투과도 향상을 위한 실험을 진행하였다. 해당 실험의 결과로, 증착된 필터는 70% 이상의 포집효율을 보이면서도 기체 투과도는 현재 상용화되어 있는 코디얼라이트보다 5배 이상 높았다. 또한 필터에 추가적인 SiC 침윤공정을 통하여 시편의 내산화성, 내마모성, 내열성 등의 특성이 향상됨을 확인하였다.

  • PDF

Fabric Filtration for Particulate Matter Collection (여과포에 의한 분진포집기술)

  • 박영옥
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.68-73
    • /
    • 1993
  • 여과포에 의한 분진 포집기술은 다른 분진포집기술에 비해 가장 우수한 집진성능을 나타낼수 있는 집진기술로서 최근에 와서는 분진발생공정, 연소설비 및 폐기물 소각설비의 중금속 물질, 유해 기체 및 분진의 동시포집 적용 등 광범위한 산업분야에 적응되어 운전되고 있다. 배출기체의 악조건과 습도가 다량 함유된 조건에서는 여과포 집진장치의 적용이 어렵다고 생각되고 있지만, 처리 기체의 조건 및 포집분진의 특성에 적합한 여과포의 개발과 탈진방식(cleaning method)의 개선으로 인해 해결이 가능하게 되었다. 또한 여과포에 의한 분진포집기술은 장치를 통과하는 배출기체의 속도가 다른 집진기술에 비해 느려 여과포 면적이 상대적으로 넓어져서 장치의 설치면적이 많이 소요된다는 단점이 있으나, 여과포를 원간으로 봉재하여 서로 접근시켜 많은 갯수를 다단으로 배치함과 동시에 연속탈진시스템(on-line cleaning)을 채택함으로써 장치에 소요되는 면적을 최소한으로 줄이려는 연구가 계속되고 있다. 대체적으로 여과포에 의한 분진포집기술의 산업체 적용에서 장치의 압력손실은 약 100 - 100 $mmH_2O$ 정도의 범위가 대부분이고 분진 포집효율은 거의 99.9%에서 99.99% 정도 달성이 가능하다[1,2,3].

  • PDF

Modified Virtual Cyclone as a Particle Concentrator (싸이클론을 이용한 에어로졸 입자의 농축)

  • 임경수;김현수;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.483-484
    • /
    • 2003
  • 일반적으로 싸이클론은 여러 산업공정에서 입자의 분리/제어를 위해서나 대기 중의 입자상 물질을 측정하기 위해서 많이 쓰여 왔다. 하지만 싸이클론은 작은 입자에 대해서는 효율이 낮고, 완만한 포집 효율 곡선을 가지고 있기 때문에, 고효율을 얻거나 이상적인 효율 곡선을 얻는 방법에 대해서 많은 연구가 집중되었다. 최근에는 입자를 분리/포집하기 위해서 싸이클론을 사용하는 것뿐만 아니라, 일정 크기의 입자를 분리하고 농축하기 위해서 가상 싸이클론(virtual cyclone)을 사용하는 연구가 진행되고 있다. (중략)

  • PDF