A Study on the Collection Efficiency of A Tritium Bubbler

삼중수소 버블러의 포집효율에 대한 고찰

  • Published : 2005.06.01

Abstract

Collection Efficiency of a tritium bubbler being used at domestic nuclear power plants was studied. Equilibrium is attained while tritium vapour in air passes through the bubbler. When a lot of gas sample passes through the bubbler, the tritium concentration of water is raised and volume of water is decreased or increased. These phenomena give effect to the collection efficiency. Estimation of the tritium concentration of the water agreed with our experiments. If relative humidity is higher than 0.5, the efficiency becomes lower than 1 and if relative humidity is lower than 0.5, the efficiency becomes higher than 1, provided collected tritium is evaluated with original volume of the water. Though the relative humidity is riot 0.5, the efficiency can be maintained near 1 by making $\frac{saturated\; water\; vapour(cm^3_w)\times volume \; of \; gas \; sample(cm^3)}{volume\; of\; water(cm^3)}$ small

국내 원전에서 공기 중 삼중수소 농도를 평가하기 위해 사용하는 삼중수소 버블러의 포집효율에 대하여 고찰하였다. 수증기 형태인 공기 중 삼중수소는 기포가 물을 통과하는 동안 평형농도에 도달하게 된다. 많은 양의 기체시료를 통과시킬 경우 포집수의 삼중수소 농도가 높아지고 포집수가 감소하거나 증가하는 현상이 발생하여 포집효율에 영향을 미치게 된다. 이러한 영향을 고려한 포집수의 예측농도는 실측값과 잘 맞았다. 통상적인 방식과 같이 초기 포집수량을 이용하여 삼중 수소 포집량을 평가할 경우 기체시료의 상대습도가 0.5보다 높으면 포집효율은 1보다 낮아지고 상대습도가 0.5보다 낮으면 포집효율은 1보다 높아진다. 상대습도가 0.5가 아니더라도 $\frac{포화수증기량\times기체통과량}{포집수량}$을 작게 하면 포집효율을 1에 가깝게 유지할 수 있다.