• Title/Summary/Keyword: 팁인

Search Result 513, Processing Time 0.028 seconds

Effect of Nozzle Tip Size on the Preparation of Nano-Sized Cobalt Oxide Powder by Spray Pyrolysis Process (분무열분해 공정에 의한 코발트 산화물 나노 분체 제조에 미치는 노즐 팁 크기의 영향)

  • Kim, Dong Hee;Yu, Jae Keun
    • Resources Recycling
    • /
    • v.25 no.6
    • /
    • pp.41-49
    • /
    • 2016
  • The present study was intended to prepare cobalt oxide ($Co_3O_4$) powder of average particle size 50 nm or less by spray pyrolysis reaction using the raw cobalt chloride ($CoCl_2$) solution, in order to identify the change in the nature of the particles according to the change in the nozzle tip size. When the nozzle tip was 1 mm, it turned out that most of the droplets were spherical and the surface showed very tight structure. The average particle size of the finally formed particles was 20-30 nm. When the nozzle tip size was 2 mm, some of the droplets formed were spherical, but a considerable part of them showed severely disrupted form. particles formed showed an average particle size of 30 - 40 nm. For the nozzle tip size of 5 mm, spherical droplets were almost non-existent and most were in badly fragmented state. The tightness of surface structure of the droplets has greatly been reduced compared with other nozzle tip sizes. Average size of the formed particles was about 25 nm. As the nozzle tip size increased from 1 mm to 2 mm and 3 mm, the intensities of the XRD peaks have changed little, but significantly been reduced when the nozzle tip size increased to 5mm. As the nozzle tip size increased from 1 mm to 2 mm, the specific surface area of the particles decreased, but the nozzle tip size increased to 5mm, the specific surface area remarkably increased.

Comparative Study of Tip Clearance Loss in Impulse and Reaction Turbine Cascades (충동터빈과 반동터빈 캐스케이드에서의 팁 간극 손실에 대한 비교 연구)

  • Park, Kyung-Wook;Jung, Eun-Hwan;Song, Seung-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.145-148
    • /
    • 2008
  • Korea Aeronautics Research Institute (KARI) is developing a turbo pump that has 1-stage impulse turbine and relatively high tip clearance for safety. The objective of this research is to investigate the effect of reaction on tip clearance loss in axial turbines. Both cascades were tested in a subsonic wind tunnel. In each cascade, total pressure was measured for tip clearance ranging from 1% to 20% of chord. In results, increasing tip clearance, total pressure loss in reaction turbines is continually increased but impulse turbines keep almost same level of mass averaged total pressure loss. When tip clearance becomes more than 10% of chord, mass-averaged total pressure loss in impulse turbines is less than in reaction. This means that when tip clearance is more than 10% of chord, impulse turbines have better efficiency than reaction turbines.

  • PDF

The Effect of Rotor Tip Geometry on the Performance of Turbopump Turbine (터보펌프 터빈의 로터 팁 형상에 따른 성능변화 연구)

  • Jeong, Eun-Hwan;Park, Pyun-Goo;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.197-204
    • /
    • 2007
  • Effect of rotor tip geometry on the performance of supersonic impulse turbine was investigated experimentally. Using the shrouded supersonic impulse turbine of the 30ton class liquid rocket engine turbopump as a base model, the measured performance of de-shrouded rotor was compared. The effect of nozzle-rotor overlap also has been investigated. It has been found that the magnitude of turbine efficiency is largely affected by the existence of the rotor shroud. However, measured efficiency sensitivity of the de-shrouded supersonic impulse turbine with respect to turbine tip clearance was relatively smaller than that of high performance reaction turbine. It also has been found that there exists nozzle-rotor overlap value which results optimum efficiency in supersonic impulse turbine.

  • PDF

A study on the feedback control system for near field scanning optical microscope based on the tuning fork oscillator (수정 진동자를 이용한 근접장광학계 (Near-Field Scanning Optical Microscope) 제작 및 특성연구)

  • 윤선현
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.267-272
    • /
    • 1999
  • We attached a fiber tip on the branch of a quartz crystal oscillator in order to make a feedback control system for near field optical microscope. The electrical impedance of the quartz crystal oscillator depends on the distance between the surface of the sample and the tip caused by the surface damping. Using this method, we can directly monitor the distance between the sample and the tip without inserting extra beam which might give extra optical noise. We characterize the XY scanning resolution and the amplitude of the vibrating tip and the Z-dependent decay of the evanescent wave.

  • PDF

Fabrication and characterization of silicon field emitter array with double gate dielectric (이중 게이트 절연막을 가지는 실리콘 전계방출 어레이 제작 및 특성)

  • 이진호;강성원;송윤호;박종문;조경의;이상윤;유형준
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.103-108
    • /
    • 1997
  • Silicon field emitter arrays (FEAs) have been fabricated by a novel method employing a two-step tip etch and a spin-on-glass (SOG) etch-back process using double layered thermal/tetraethylortho-silicate (TEOS) oxides as a gate dielectric. A partial etching was performed by coating a low viscous photo resist and $O_2$ plasma ashing on order to form the double layered gate dielectric. A small gate aperture with low gate leakage current was obtained by the novel process. The hight and the end radius of the fabricated emitter was about 1.1 $\mu\textrm{m}$ and less than 100$\AA$, respectively. The anode emission current from a 256 tips array was turned-on at a gate voltage of 40 V. Also, the gate current was less than 0.1% of the anode current.

  • PDF

Spray Characteristics of a Movable Pintle Injector with Pintle Tip Shape (가변 핀틀 인젝터에서 핀틀 팁 형상에 따른 분무특성 연구)

  • Nam, Jeongsoo;Lee, Keonwoong;Park, Sunjung;Huh, Hwanil;Koo, Jaye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.9
    • /
    • pp.658-664
    • /
    • 2019
  • In the development of the liquid rocket engine using the pintle injector, spray characteristics such as spray angle, droplet size, and distribution of the droplets are dominant parameters. Three different kind of multi hole type pintle tip and a continuous type pintle tip were designed. In the case of multi hole pintle tip, SMD result did not have a significant difference depending on the number of holes. In analysis with visualization images, however, the droplets were uniformly distributed as the number of holes increased. Liquid droplets from continuous type pintle tip were finely atomized and dispersed uniformly than those from multi-hole type pintle tip. In addition, the thrust control by adjusting the liquid injection area of the pintle is suitable for the continuous type, which is easier to face-shutoff rather than the multi hole type. The spray angle of each pintle tip according to TMR was measured to derive a specific tendency and corresponding empirical formula.

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

Electrostatic Microactuators operated at low drive voltages Using Triangular Tip (삼각 팁을 이용한 저전압 구동형 정전방식 마이크로액추에이터)

  • Kim, Bong-Hwan;Seong, U-Gyeong;Jeon, Guk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.9
    • /
    • pp.605-610
    • /
    • 2001
  • Electrostatic comb-drive microactuators with sub-micron gap were fabricated and tested. We designed and fabricated two type of electrodes which are rectangular and triangular tip. The fabricated microactuators with triangular tip resulted in the electrode gaps in the range of 0.55 ${\mu}{\textrm}{m}$~1.35 ${\mu}{\textrm}{m}$ Displacement of 1 ${\mu}{\textrm}{m}$ and electrostatic force of 2.3 $\mu$N were observed in a triangular-tip microactuator with 0.55 ${\mu}{\textrm}{m}$ gap when a DC drive voltage of 13 volts was applied. Measured 1st resonance frequency of microactuators was about 23 kHz.

  • PDF

Study on Tip Clearance Effect of a Counter-Rotating Ducted Fan for VTOL UAV (수직이착륙 무인항공기용 엇회전식 덕티드팬의 팁간극 영향에 대한 연구)

  • Min, Junho;Ryu, Minhyoung;Lee, Seawook;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.516-523
    • /
    • 2013
  • The tip clearance effect on counter-rotating ducted fan of VTOL UAV in hovering condition, was investigate using computational analysis. The $k-{\omega}$ SST turbulence model is employed in this study. The numerical results of baseline model are validated by wind tunnel test in hovering and forward conditions. It is observed that if tip clearance of one rotor in the counter-rotating ducted fan increase then the thrust coefficient of another rotor increases. In Addition to this, when the tip clearance of the rear rotor increases, the thrust of the ducted fan is improved due to increasing of average total pressure at exit plane.