• Title/Summary/Keyword: 통수

Search Result 394, Processing Time 0.027 seconds

A Study of the Conveyance Increasement for Urban River using 1, 2-Dimensional Numerical Model (1, 2차원 수치모형에 의한 도시하천의 통수능 확보 방안에 관한 연구)

  • Baek, Chun-Woo;Park, Moo-Jong;Kim, Seok-Woo;Jo, Deok-Jun;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.73-82
    • /
    • 2005
  • The scheme for the conveyance increasement of urban river is presented in this study. For the use of the lower part of the road paralleled to urban river as a conveyance, the 2-dimensional flood flow between main channel and added conveyance section is analyzed by mathematical model SMS(2-D simulation model). The result of the HEC-RAS(1-D simulation model) is used to calibrate the parameters of SMS. New scheme is applied to the Cheonggeyecheon Restoration Project. The capacity of flood flow between main channel and added conveyance is simulated for 50, 80, 200 year frequency flood and suitable size of pathway is proposed.

Suggesting a Demand Forecasting Technique Explicitly Considering Transfers In Light Rail Transit Protect Analysis (신교통수단 건설사업에 있어 환승을 반영한 교통수요 예측기법)

  • Kim, Ik-Gi;Han, Geun-Su;Bang, Hyeong-Jun
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.3 s.89
    • /
    • pp.197-205
    • /
    • 2006
  • The study suggested a demand forecasting method which explicitly reflects transfer between various transport modes especially related light rail transit project with multi-modal transit system. The suggested method classifies several groups depending on characteristic of trips and applies different demand model for each group to explain travel pattern more realistically More specifically. the trips was classified by trips within the LRT route, trips between inside and outside of the LRT route. and through trips via the LRT route. The study also suggested a evaluation measurement of time saving due to the LRT construction, which are consistent along with the do-case and the do-nothing-case even though some mode shift could be happen after introducing the LRT.

A Study on the Characteristics of Unsaturated Discharge Capacity of Horizontal Drains (수평배수재의 불포화 통수특성 연구)

  • 장연수;박정순;박정용
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.15-25
    • /
    • 2003
  • To evaluate the effect of trapped air bubbles in horizontal drains on discharge capacity, unsaturated discharge capacity tests are carried out for four types of drains selected according to the size of section as well as the shape of core. Unsaturated discharge capacities with the elapse of time, the increase of confining pressures, and hydraulic gradients are examined and are compared with saturated discharge capacities. It is found that the unsaturated discharge capacities at a hydraulic gradient of 0.01 decreased by 17%~80% due to the remained air bubbles in the drains compared with the saturated discharge capacities. It is caused by the fact that the horizontal direction of water flow is not consistent with the direction of movement of floating air bubbles in case of horizontal drains. Especially, far the drain with filament shaped core, discharge capacities decreased significantly due to the difficulty in removing air bubbles.

Estimation on Discharge Capacity of Prefabricated Vortical Drains Considering Influence Factors (영향인자를 고려한 연직배수재의 통수능 평가)

  • Shin Eun-Chul;Park Jeong-Jun;Kim Jong-In
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.9
    • /
    • pp.13-23
    • /
    • 2005
  • The prefabricated vertical drains (PVDs) are one of the most widely used techniques to accelerate the consolidation of soft clay deposits and dredged soil. Discharge capacity is one of the factors affecting the behavior of PVDs. In the field, a PVD is confined by clay or dredged soil, which is normally remolded during PVD installation. Under field conditions, soil particles may enter the PVD drainage channels, and the consolidation settlement of the improved subsoil may cause 131ding of the PVD. These factors will affect the discharge capacity of the PVDs. In this study an experimental study was carried out to estimate the discharge capacity of three different types of PVDs by utilizing the large-scale laboratory model testing and small-scale laboratory model testing equipments. The several factors such as confinement condition (confined by soft marine clay or dredged soil) and variations of the discharge capacity were studied with time under soil specimen confinement, The test results indicated that discharge capacity decreases with increasing load, time, and hydraulic gradient. With load application, the cross-sectional area of the drainage channel of PVD decreases because the filter of PVD is pressed into the core. The discharge capacity of the soft marine clay-confined PVDs is much lower than that of the dredged soil-confined PVDs.

Experimental Study on the Reduction of the Discharge Capacity of Vertical Drains (연직배수재의 통수능력 저감요인 분석을 위한 실험적 연구)

  • Kim, Chan-Kee;Chae, Young-Su;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.3
    • /
    • pp.3-10
    • /
    • 2005
  • This paper aims at investigating the characteristics of discharge capacity according to lateral pressure, hydraulic gradient and deformation of drain materials. A series of experiments were conducted to achieve this objective. In experiments, fiver drain boards as well as harmonica and castle types of drain boards were installed in a rubber membrane, and clay in sully was filled around them. The test results showed that the harmonica type of drain boards have the greatest discharge capacity comparing to castle and fiber drain boards. The results also indicated that the hydraulic gradient has more effect on reduction of discharge capacity than the lateral pressure.

  • PDF

A Study on Discharge Capacity of Vertical Drain Considering with In-situ Soil Condition (원지반조건을 고려한 연직배수재의 통수능에 관한 연구)

  • Park, Min-Chul;Kim, Eun-Chul;Lee, Song
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • Discharge capacity of PBD is sensitive in proportion to thickness and ground condition, and drainage of PBD declines due to disturbance effect in surrounding ground by mandrel used for vertical drainage setting and setting machines and type. Also, deviation of discharge capacity gets larger according to ground condition, construction condition and soil properties. But cause and analysis of those problems like reduced discharge of capacity and delayed dissipation of pore water pressure for discharge capacity is lack. Thus, in this text, ground improvement and discharge capacity is investigated by implementing composite discharge capacity test for analysis of an effect factor of PBD discharge capacity with in-situ ground condition. After fixing the vertical drain on a cylindrical cylinder, put churned sample into the cylinder. After in-situ ground and reclamation of ground are dredged, load following the loading step of 30, 70 and 120kPa using a pressure device. Result of the test, The discharge capacity was SM>ML>CL>CL(dredged soil) in situ condition and more fine-grained content, the amount of discharge was greater.

Development and Applicability of Discharge Capacity Testing Apparatus Using Penetration Method (관입식 복합 통수능 시험기의 개발과 적용성)

  • Yoo, Nam Jae;Kim, Dong Gun;Park, Byung Soo;Jun, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.313-320
    • /
    • 2008
  • The discharge capacity testing apparatus using penetration method, being able to simulate in laboratory the condition of embedding plastic board drains in field, was developed to investigate consolidation characteristics of ground and to figure out discharge capacity of drains. The developed apparatus with a mandrel and penetrating device was designed to insert PBD into the ground prepared by previously applied pressure, being different from the conventional testing method that the drain was installed and the ground material was poured subsequently. Discharge capacity tests with the conventional apparatus as well as the newly developed one were performed to assess the applicability of the latter. As a result of tests, the conventional method showed delayed consolidation due to overall disturbance of ground and local deformation of drain caused by inhomogeneity of ground. Therefore discharge capacity of drain with the conventional apparatus was measured more or less larger than the expected values whereas discharge capacity with new one could be measured similar to the actual value in field.

Evaluation of Required Discharge Capacity for Prefabricated Vertical Drains (연직배수재의 소요통수능 평가)

  • 김상규;김현태;공길용
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2001
  • Bergado에 의해 비교 분석된 많은 연구자들의 배수재의 소요통수능에 대한 제안값을 보면 0.32~50cc/s로 그 차이가 너무 크기 때문에 실무에 적용하기가 어렵다. 본 연구에서는 배수재의 통수능변화를 고려할 수 있는 압밀해석방법을 개발하고, 흙의 압밀계수, 압축지수, 배수재 타설심도 및 타설후 시간경과에 따른 배수재의 통수능 감소 등의 현장여건을 고려한 압밀해석을 통하여 압밀지연을 일으키지 않는 배수재의 소요통수능에 대한 기준을 제시하였다. 압밀해석결과 어느값 이상의 통수능에서는 압밀지연이 없으므로 이 값 이상의 통수능을 갖는 배수재를 선택하는 것이 중요하며, 압밀지연시간 5% 이내인 배수재의 소요통수능은 압밀계수($c_{v}$ ), 배수재의 길이(L) 및 압축지수($C_{c}$)와 비례관계로서 안전율 1.5를 고려하여 $q_{wa}$ =8$\times$($c_{v}$ $\times$L$\times$$C_{c}$)(cc/s) 이상이면 되는 상관식을 얻었다. 이 값 이상의 배수재를 선택하는 경우는 연직배수공법의 압밀해석에서 배수재의 통수능을 고려하지 않아도 된다는 결론을 얻었다.

  • PDF

Backwater Evaluation Method of Tributary Stream by Operating Serial Weir in Nakdong River (낙동강 직렬보의 관리수위 운영에 따른 지류하천 배수기능 평가기법)

  • Jung, Sung-Soon;Choo, Tai-Ho;Jee, Hong-Ki
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.392-396
    • /
    • 2011
  • 본 연구는 자연하천에서 직렬보 설치에 따른 배수위 계산을 실시하여 여러 가지 수리특성인자들의 결과와 비교해 보았다. 그 결과, 자연수위에 따른 통수단면적보다 수위증가로 인한 통수단면적의 영향이 가장 큰 것으로 분석되었다. 그러나 유속을 포함한 다른 수리특성인자의 영향은 다소 적은 것으로 분석되었다. 따라서 보(weir)를 설치할 경우 다른 수리특성인자보다 수위상승에 따른 통수단면의 통수능력이 먼저 검토되어야 할 것이다. 또한 자연하도에 비해 수중보 설치에 의한 상류의 수위상승 종단거리가 예상치보다 매우 크게 나타나고 있었기 때문에 보 설치에 따른 종단거리의 영향을 파악하여 제방설계를 실시해야 할 것으로 판단된다. 보의 설치는 수위증가로 인한 용수확보, 수변공간 확보 등 많은 이점이 있으나, 홍수시의 하도통수능력 고려, 오염물질의 퇴적으로 인한 수질오염 방지 그리고 갈수시에 하천의 유지용수 확보 등을 고려한 신중한 분석 검토를 해야 할 것으로 사료된다.

  • PDF

Discharge Capacity for Vertical Drain Boards with Hydraulic Gradient Variation (동수경사 변화에 따른 연직배수재의 통수능)

  • Kim, Ju-Hyong;Lee, Kwang-Wu;Cho, Sam-Deok;Chang, Gap-Shik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.2
    • /
    • pp.11-20
    • /
    • 2010
  • This paper studies the discharge capacity of vertical drain boards that is controlling hydraulic gradient among many factors in the specification. The KS K 0940(2008), a testing method based on the conventional Delft type method for measuring the discharge capacity of a vertical drain, was specified in Korea Standard recently. In this test method, the variation in hydraulic gradient can result in large differences in the discharge capacity for the same vertical drain board.

  • PDF