Abstract
To evaluate the effect of trapped air bubbles in horizontal drains on discharge capacity, unsaturated discharge capacity tests are carried out for four types of drains selected according to the size of section as well as the shape of core. Unsaturated discharge capacities with the elapse of time, the increase of confining pressures, and hydraulic gradients are examined and are compared with saturated discharge capacities. It is found that the unsaturated discharge capacities at a hydraulic gradient of 0.01 decreased by 17%~80% due to the remained air bubbles in the drains compared with the saturated discharge capacities. It is caused by the fact that the horizontal direction of water flow is not consistent with the direction of movement of floating air bubbles in case of horizontal drains. Especially, far the drain with filament shaped core, discharge capacities decreased significantly due to the difficulty in removing air bubbles.
수평배수재 내의 기포로 인한 불포화상태가 통수능에 미치는 영향을 평가하기 위하여 단면 크기 및 코어 형태에 따라 4종류의 배수재를 선정하여 불포화 통수능력시험을 실시하였다. 가압시간, 구속압, 동수경사 등의 변화에 따른 불포화 통수능의 변화를 분석하고 포화 통수능과 비교하였다. 분석결과, 불포화 통수능은 동수경사가 0.01인 경우, 포화 통수능에 비해 배수재 내에 적체된 잔류기포의 영향으로 인해 17%~80% 감소하였다. 이는 수평배수재의 경우, 수평으로 흐르는 물의 흐름 방향과 부양되려는 기포의 이동방향이 서로 일치하지 않기 때문으로 평가된다. 특히 배수재의 코어 형상이 필라멘트 모양인 경우 기포가 빠져나가기 어려워 불포화 통수능이 크게 저하되었다.